- 24 -
10. LED
The BHT has two LEDs, a display LED (red/blue) to notify the operator that barcode reading is complete, and a
charge LED (red/green) to notify the operator of the charge status.
The illumination status for the display LED can be controlled from the application.
The illumination status is set and acquired using a 2D indexer. The illumination device (display (barcode) LED only
on BHT-400) is specified for the first index, and the illumination color (red or green) is specified for the second
index.
[Ex.] Turn ON the red display LED.
[VB] MyLED. (LED.EN_DEVICE.BAR,LED.EN_COLOR.RED) _
= LED.EN_CTRL.ON
[C#]
MyLED[LED.EN_DEVICE.BAR,LED.EN_COLOR.RED]
= LED.EN_CTRL.ON
The priority order relationship is as follows:
(Barcode read based control) > (application based control)
If “Turn ON LED when barcode reading complete.” is specified and barcode reading is enabled, the display LED
illumination status cannot be controlled from the application until barcode reading is next disabled.
The illumination request from the application, however, is retained in the variable flag (RAM) inside the LED driver.
Illumination requests are also set and cleared while barcode reading is enabled. When barcode reading is
disabled, the flag is checked and the LED color for which an illumination request exists is turned ON automatically.
[Ex.]
Red Green
Status OFF OFF
Rqst. No
No
Red Green
Status ON OFF
Rqst. Yes
No
Red Green
Status OFF OFF
Rqst. Yes
No
Red Green
Status ON OFF
Rqst. Yes
No
Red Green
Status ON
ON
Rqst. Yes Yes
Red Green
Status OFF OFF
Rqst. Yes Yes
Red Green
Status OFF OFF
Rqst. No
Yes
Red Green
Status OFF ON
Rqst. No
Yes
Reading enabled
Red LED ON
specified from
application.
Reading disabled
Blue LED ON
specified from
application.
Reading enabled
[Default status]
Red LED OFF
specified from
application.
Reading disabled
Red LED ON
Blue LED ON
Содержание BHT-400-CE
Страница 1: ...Class Library Reference Manual Bar Code Handy Terminal BHT 400 CE ...
Страница 49: ... 43 17 9 LED UsageCollection This class is invalid at the BHT 400 ...
Страница 66: ... 60 17 26 Display This function is not supported ...
Страница 67: ... 61 17 27 Display Settings This function is not supported ...
Страница 78: ... 72 Events Event Name Description OnDone Occurs when decoding is complete Enumeration None ...
Страница 166: ... 160 18 9 LED UsageCollection This class is invalid on the BHT400 ...
Страница 289: ... 283 18 26 Display This function is not supported ...
Страница 290: ... 284 18 27 Display Settings This function is not supported ...
Страница 296: ... 290 C MySysMod FileName SysModification BHT400New zl MySysMod Mode SysModification EN_MODE POWEROFF MySysMod Execute ...