a) Loosen the screw on the left side panelling and take off the cover.
b) Screw in the small outlet pipe.
c) Place an adequate container to catch the old oil next to the generator.
d) Drain the oil completely.
e) Ensure that the generator is horizontal, then fill recommended oil in up to the top edge of the
filling nozzle.
f) Replace left side panelling and tighten fixing screw.
Wash hands after handling old oil.
Attention!
Improper disposal of old oil can cause environmental pollution. If you change the oil yourself,
please ensure environmental-friendly disposal. Fill oil into a closed container and take it to the
collecting point. Do not dispose in waste or onto ground or into the drain.
2. Maintenance of air cleaner
A dirty air cleaner hinders the air inflow of the carburetor. Service the air cleaner regularly to avoid a
malfunction of the carburator. Shorter maintenance intervals are necessary if the generator is operated
under very dusty conditions.
Oil drain
Oil box
Maximum filling level
gauge
cover for oil gauge