Error
Code
Details of Error code
Display
Coping strategies
5E
Abnormal data in UpdatePacket
received from DM860A
(CheckSumError).
S u b
* * * m i n
U p d a t i n g
f a i l
5 E
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error
display, press and hold the "Power
operation (
X
)" button for five seconds.
5F
Abnormal data in UpdatePacket
received from DM860A
(DataLength/DataNo).
S u b
* * * m i n
U p d a t i n g
f a i l
5 F
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error
display, press and hold the "Power
operation (
X
)" button for five seconds.
60
NACK received in response or no
response from Sub for P command.
S u b
* * * m i n
U p d a t i n g
f a i l
6 0
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error
display, press and hold the "Power
operation (
X
)" button for five seconds.
61
Mismatched CheckSum in response
or no response from Sub for I
command.
S u b
* * * m i n
U p d a t e C h e c k N G
6 1
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error
display, press and hold the "Power
operation (
X
)" button for five seconds.
62
Sub μ-com failed to start in the
POWER ON sequence during
Update.
S u b
* * * m i n
U p d a t i n g
f a i l
6 2
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error
display, press and hold the "Power
operation (
X
)" button for five seconds.
63
Failed to transit to ApplicationMode.
S u b
* * * m i n
U p d a t i n g
f a i l
6 3
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error
display, press and hold the "Power
operation (
X
)" button for five seconds.
64
Failed to transit to BootLoaderMode.
* * * m i n
U p d a t i n g
f a i l
6 4
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error
display, press and hold the "Power
operation (
X
)" button for five seconds.
80
WriteEnableLatchBit not set in Read
after issuing WREN command.
G U I
* * * m i n
U p d a t i n g
f a i l
8 0
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error
display, press and hold the "Power
operation (
X
)" button for five seconds.
81
BlockErase failed in Read after
issuing BE command.
G U I
* * * m i n
U p d a t i n g
f a i l
8 1
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error
display, press and hold the "Power
operation (
X
)" button for five seconds.
82
No UpdatePacket received from
DM860A (TimeOut).
G U I
* * * m i n
U p d a t i n g
f a i l
8 2
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error
display, press and hold the "Power
operation (
X
)" button for five seconds.
83
Abnormal data in UpdatePacket
received from DM860A
(FormatError).
G U I
* * * m i n
U p d a t i n g
f a i l
8 3
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error
display, press and hold the "Power
operation (
X
)" button for five seconds.
84
Abnormal data in UpdatePacket
received from DM860A
(CheckSumError).
G U I
* * * m i n
U p d a t i n g
f a i l
8 4
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error
display, press and hold the "Power
operation (
X
)" button for five seconds.
85
Abnormal data in UpdatePacket
received from DM860A
(DataLength/DataNo).
G U I
* * * m i n
U p d a t i n g
f a i l
8 5
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error
display, press and hold the "Power
operation (
X
)" button for five seconds.
86
Mismatched CheckSum in
CheckSum comparison after
rewriting.
G U I
* * * m i n
U p d a t i n g
f a i l
8 6
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error
display, press and hold the "Power
operation (
X
)" button for five seconds.
90
Содержание IN-Command AVR-X4000
Страница 8: ...Personal notes 8...
Страница 19: ...Personal notes 19...
Страница 64: ...Personal notes Personal notes 64...
Страница 110: ...Personal notes 110...
Страница 164: ...Personal notes Personal notes 164...
Страница 170: ...R5F3650KNFB DIGITAL IC231 170...
Страница 176: ...W9864G6JH 6 DIGITAL IC409 W9864G2IH Publication Release Date Aug 28 2009 4 Revision A03 4 PIN CONFIGURATION 176...
Страница 179: ...MX25L1606EM2I 12G DIGITAL IC410 IC423 MX25L1606EM2I 12G Block Diagram 8 PIN SOP 200mil 150mil BLOCK DIAGRAM 179...
Страница 181: ...AK5358BET DIGITAL IC451 AK5358BET Pin Function 181...
Страница 194: ...2 FL DISPLAY FLD 17 BT 40GINK FRONT FL601 PIN CONNECTION GRID ASSIGNMENT Y2 q 194...
Страница 195: ...ANODE CONNECTION 195...