4. Protection Pass mode
4.1. Specifications
• Turn the power on with Protection disabled.
Except for disabling the Protection detection, this operation is the same as the normal power on.
4.2. Operation
1. Press the "Power Operation (
X
)" button while pressing
"ZONE3 SOURCE"
and
"STATUS"
and
"Cursor
0
"
buttons on the set to turn the power on.
2. The POWER ON sequence starts. The Protection detection is disabled.
FLD
P r o t e c t i o n
P a s s
This is displayed for 5 seconds before returning to the normal display.
5. DM860A Reboot mode
5.1. Specifications
• When DM860A is hung up, DM860A is restarted.
Even when Network standby is set (Setup Menu - Network - Network - Always ON), DM860A can be reset.
5.2. Operation
1. Turn on MAIN ZONE button, and select NETWORK for the input source.
2. Press and hold the
"DIMMER"
and
"SETUP"
buttons for 3 seconds and longer.
3. DM860A is restarted and returns to the normal display.
FLD
N e t w o r k
R e s t a r t
NOTE:
The same operation cannot be accepted for one minute after the last 860 Reboot.
68
Содержание IN-Command AVR-X4000
Страница 8: ...Personal notes 8...
Страница 19: ...Personal notes 19...
Страница 64: ...Personal notes Personal notes 64...
Страница 110: ...Personal notes 110...
Страница 164: ...Personal notes Personal notes 164...
Страница 170: ...R5F3650KNFB DIGITAL IC231 170...
Страница 176: ...W9864G6JH 6 DIGITAL IC409 W9864G2IH Publication Release Date Aug 28 2009 4 Revision A03 4 PIN CONFIGURATION 176...
Страница 179: ...MX25L1606EM2I 12G DIGITAL IC410 IC423 MX25L1606EM2I 12G Block Diagram 8 PIN SOP 200mil 150mil BLOCK DIAGRAM 179...
Страница 181: ...AK5358BET DIGITAL IC451 AK5358BET Pin Function 181...
Страница 194: ...2 FL DISPLAY FLD 17 BT 40GINK FRONT FL601 PIN CONNECTION GRID ASSIGNMENT Y2 q 194...
Страница 195: ...ANODE CONNECTION 195...