7. DPMS UP date mode
Update the firmware of DPMS.Refer to [ VERSION UPGRADE PROCEDURE OF FIRMWARE "2. How to update by
DPMS" ].
Error code table
•
Preparation operation rewritten, Update error code checking. (Check ETHERNET unit)
Error Code
Details of Error code
Coping strategies
01
Login failed(DPMS Access Login Incorrect notification)
Reset and update again. Carry out the update in an environment
that has little network load.
02
Login failed(DPMS Access Server Busy information)
Carry out the update in an environment that has little network
load.
03
Login failed(DPMS Access link failure information)
Check the network connection. Carry out the update in an
environment that has little network load.
04
Firm Info response acquisition error recived
Check the network connection. Carry out the update in an
environment that has little network load.
05
Firm Info response acquisition TimeOut
Check the network connection. Carry out the update in an
environment that has little network load.
06
All Firm Info response acquisition error recived
Check the network connection. Carry out the update in an
environment that has little network load.
07
All Firm Info response acquisitionTimeOut
Check the network connection. Carry out the update in an
environment that has little network load.
08
Main Firm Info response acquisition error recived
Check the network connection. Carry out the update in an
environment that has little network load.
09
Main Firm Info response acquisition TimeOut
Check the network connection. Carry out the update in an
environment that has little network load.
0A
DownLoad failed ((NG)information recieved)
Check the network connection. Carry out the update in an
environment that has little network load.
0B
DownLoad failed((ServerBusy) information recieved)
Check the network connection. Carry out the update in an
environment that has little network load.
0C
DownLoad failed((connection failed)information
recived)
Check the network connection. Carry out the update in an
environment that has little network load.
• Firm error codes at the main microprocessor rewritten. (Check main microprocessor )
Error Code
Details of Error code
Coping strategies
10
Firm Info response acquisition TimeOut(Main rewrite
Firmware recived failure(TimeOut))
Turn off and on the power. Updating starts automatically.
11
Firm Info response acquisition recived error(Main
rewrite Firmware recived failure(Error)
Turn off and on the power. Updating starts automatically.
12
Firm Info response acquisition recived
error (Main rewirte Firmware recived data
incorrect(CheckSumError))
Turn off and on the power. Updating starts automatically.
13
Rewrite failure (BlockErase failued before Main
rewriting )
Turn off and on the power. Updating starts automatically.
14
Rewrite failure (BlockWrite failued before Main
rewriting)
Turn off and on the power. Updating starts automatically.
15
Rewrite failure (Verify incorrect after Main rewriting)
Turn off and on the power. Updating starts automatically.
20
Failed to acquire the IP Address after transitioning to
the Boot Loader Mode (AutoIP)
Carry out the update in an environment that has little network
load.
21
Failed to acquire the IP Address after transitioning to
the Boot Loader Mode (AutoIP)
Carry out the update in an environment that has little network
load.
22
Login failed (DPMS Access Login Incorrect notification),
after moved BootLoaderMode. (AutoIP)
Carry out the update in an environment that has little network
load.
23
Received "Server congestion" notification, after moved
BootLoaderMode. (AutoIP)
Carry out the update in an environment that has little network
load.
24
Received "connection failed", after moved
BootLoaderMode. (AutoIP)
Carry out the update in an environment that has little network
load.
36
Login failure(DPMSAccess Login incorrect infomation) Carry out the update in an environment that has little network
load.
37
Login failure(DPMSAccess Server busy infomation)
Carry out the update in an environment that has little network
load.
38
Login failure(DPMSAccess connection failed
infomation)
Check the network connection. Carry out the update in an
environment that has little network load.
39
Login failure(DPMSAccess access TimeOut)
Check the network connection. Carry out the update in an
environment that has little network load.
3A
DownLoad failure(Download error (NG)information
recieved)
Turn off and on the power. Updating starts automatically. Carry
out the update in an environment that has little network load.
Содержание CEOL Piccolo DRA-N5
Страница 17: ...17 5 Remove the MAIN BOARD Shooting of photograph D...
Страница 40: ...40 Personal notes...
Страница 62: ...62 PCM9211 AMP IC103...
Страница 63: ...63 PCM9211 Block Diagram...
Страница 64: ...64 PCM9211 Pin Discriptions...
Страница 70: ...70 L6565 SMPS IC821 L6565 Block Diagram...
Страница 71: ...71 ICE3BR1765J SMPS IC871 ICE3BR1765J Block Diagram...
Страница 72: ...72 2 DISPLAY S020 MXS4035A 3 DISPLAY CP661...