- 11 -
EVENT
PARAMETER
function
example
*RES.
ZM
ON
MAIN-ZONE ON/OFF change
ZMON<CR>
OFF
ZMOFF<CR>
Z1
PHONO
MULTI ZONE -1 source change
Z1PHONO<CR>
|
---The name of PARAMETER is
|
CDR/TAPE1
the same as that of the time of SI COMMAND.
Z1CDR/TAPE1<CR>
SOURCE
MULTI ZONE -1 mode cancel
Z1SOURCE<CR>
**
MULTI ZONE -1 VOLUME change , **:00 to 99 by ASCII
Z180<CR>
98 = +18dB(MAX)
80 = 0dB
10 = -70dB
99 = ---(MIN)
ON
MULTI ZONE -1 ON/OFF change
Z1ON<CR>
OFF
Z1OFF<CR>
---means MULTI ZONE functions at AVR-2803
Z2
PHONO
MULTI ZONE -2 source change
Z2PHONO<CR>
|
---The name of PARAMETER is
|
CDR/TAPE1
the same as that of the time of SI COMMAND.
Z2CDR/TAPE1<CR>
SOURCE
MULTI ZONE -2 mode cancel
Z2SOURCE<CR>
**
MULTI ZONE -2 VOLUME change , **:00 to 99 by ASCII
Z280<CR>
98 = +18dB(MAX)
80 = 0dB
10 = -70dB
99 = ---(MIN)
ON
MULTI ZONE -2 ON/OFF change
Z2ON<CR>
OFF
Z2OFF<CR>
---Invalid at AVR-2803
SR
PHONO
REC SELECT source change
SRPHONO<CR>
|
---The name of PARAMETER is
|
CDR/TAPE1
the same as that of the time of SI COMMAND.
SRCDR/TAPE1<CR>
SOURCE
REC SELECT mode cancel
SRSOURCE<CR>
The
PARAMETER
of Z1, Z2
EVENT
: Uses two or three ASCII characters. (see page4 J) section)