The Type 2050 external connections are via an IP66 Amphenol connector with 3 metre composite cable
flying lead comprising co-ax, power pair & RS485 pair. This lead should be connected to the boxed
P.S.U. supplied with the dome. The connections are as follows:

Fig.16

Electrical connections 

Red wire

.......24V a.c. live

Blue wire

......24V a.c. neutral

The co-ax and power wires are always connected, the RS 485 wires are only connected when an 
external protocol converter is fitted or an RS485 controller is being used.

Fig.17

Address chart 

Co-ax.  (Video)

Multicore cable with
integral Co-ax (Video)

Yellow wire

.......R.S. 485 ‘A’

Green wire

.......R.S. 485 ‘B’

Co-ax screen

........BNC screen

Co-ax signal

........BNC centre pin

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

0

1

2

3

4

5

6

7

8

9

A

B

C

D

E

F

YELLOW

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

65

66

67

68

69

70

71

72

73

74

75

76

77

78

79

80

81

82

83

84

85

86

87

88

89

90

91

92

93

94

95

96

97

98

99

100

101

102

103

104

105

106

107

108

109

110

111

112

113

114

115

116

117

118

119

120

121

122

123

124

125

126

127

128

129

130

131

132

133

134

135

136

137

138

139

140

141

142

143

144

145

146

147

148

149

150

151

152

153

154

155

156

157

158

159

160

161

162

163

164

165

166

167

168

169

170

171

172

173

174

175

176

177

178

179

180

181

182

183

184

185

186

187

188

189

190

191

192

193

194

195

196

197

198

199

200

201

202

203

204

205

206

207

208

209

210

211

212

213

214

215

216

217

218

219

220

221

222

223

224

225

226

227

228

229

230

231

232

233

234

235

236

237

238

239

240

241

242

243

244

245

246

247

248

249

250

251

252

253

254

255

BLUE

0
1
2
3
4
5
6
7
8
9
A
B
C

D
E
F

ADDRESS SWITCHES

Electrical Connections

2050 coax

operation manual                                                 Sheet. 

9

Содержание 2050

Страница 1: ...Type 2050 coax ...

Страница 2: ...FA zoom cam Introduction Congratulations on choosing a Dennard Series 2050 Precision Dome camera This operation manual provides detailed information on the extensive mounting variations available with the Series 2050 surveillance domes Models covered in this guide include 2050 2050drx 2050wp 2050drx WP and 2050 FA This operation manual will provide all the necessary information to install the Seri...

Страница 3: ...ety bond D 1 x Flying lead connector E 1 x Fixing bag containing the following 4 x M6x16 Soc cap hd screws 1 x M6 Plain nut 1 x M6 Spring washer 1 x M6 Plain washer 1 x 5mm A F Hexagonal socket key 1 x 4mm A F Hex socket key In addition to the above components a type 2050 product guide a 2050 menu system manual and a final test procedure are supplied List of contents 2050 coax operation manual She...

Страница 4: ...ket order suffix CM for solid or suspended ceilings 6 Tile mount order suffix TM for suspended ceilings 7 Side Entry order suffix SE for use when cabling through ceiling is not possible 8 Corner Bracket order suffix CB for mounting to corners of buildings 9 Extended corner mount order suffix ECM for mounting to corners of buildings 10 Extended wall mount order suffix EWM for extending out from a w...

Страница 5: ...4 Fit bond over M6 stud position B and secure with M6 nut plain washer spring washer supplied Clip carbine to eyelet E on dome to secure see sheet 5 Ceiling mounting instructions for details on eyelet mounting Note Always support dome with bond prior to mating connector C Weight of dome should be supported by bond ensuring no stress is placed on centre connector C at any time Fig 3 Safety bond Bra...

Страница 6: ...ed into bushes as shown C Attach transfer disc E to top of dome enclosure G with 4 off M6 dome hd self tapping trilobular screws D pre fitted fig 6 Note Fit safety bond bracket F as shown Offer dome enclosure to ceiling mounting disc fig 7 engaging the screw heads C into keyhole slots G Twist to locate and tighten fixings C to secure Please ensure safety bond is fitted as descibed on sheet 4 Fig 7...

Страница 7: ... wall until flush C Offer bracket base casting into position screw wall fixing screws through into inserts D Tighten fixings to secure Note An optional spreader plate SP is recommended when fixing to brickwork to reduce the pull out forces on a single brick Available from Dennard on request Note Locating a dome on a corner of a building will give an increased area of surveillance For this reason D...

Страница 8: ... item D as shown in fig 13 If not already fitted adhere Velcro strips to hemisphere flange and likewise to the inside face of the trim bezel suppled Simply offer bezel over hemisphere into position aligning Velcro strips to ensure a good bond is achieved as shown in fig 14 Fit safety bond supplied to attachment point shown in fig 12 Fig 14 Bezel mounting Fig 11 Ceiling hole pattern Fig 13 Mounting...

Страница 9: ...rbine to eyelet as shown B Mate central connector supplying power control to dome ensure power is off when connecting C Lift dome to bracket flange ensuring head of screws previously fitted M6x12 Trilobular self tapping screws pass through keyhole slots Twist to locate D Tighten 4 top mounting fixings with 4mm A F Hexagonal key supplied to secure ...

Страница 10: ...23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 1...

Страница 11: ...used i e BAX AC PANEL Blue F Yellow C 252 For Baxall a c controllers DEN PANEL Blue F Yellow D 253 For Dennard BBV DM Sprite controllers BAX DC PANEL Blue F Yellow E 254 For Baxall d c controllers For up the co ax control using external protocol con verters like the drx 100 or DAX DEN the address switches should be set to Blue 0 Yellow 1 1 To access the address switches remove the outer hemisphere...

Страница 12: ...0drx Domes are delivered with address switches set at 1 Local 230Va c Input drx 100 PSU drx 100 PSU Fig 20 Twisted Pair Configuration 1 to 16 Dome Cameras Twisted Pair 20mA current loop Video cable to Controller Video cable to Controller Local 230Va c Input PSU PSU PSU Fig 21 Up the co ax Configuration 1 to 16 Dome Cameras Video cable to Controller Video cable to Controller Local 230Va c Input Loc...

Страница 13: ...RS485 Up the Co Ax Configuration drx options Circuit Diagrams 2050 coax operation manual Sheet 12 ...

Страница 14: ...ADDENDUM Addendum 1 Type 2050 FA Fixed Attitude Dome Addendum 2 Type 2050 FA Electrical Connections Addendum 3 Type 2050 FA Zoom Cam Set Up 2050 coax operation manual Sheet 13 ...

Страница 15: ...rotate This adjustment provides 180º of pan right left movement Tip Do not wind more than 180º in one direction as this will stress the connections to the camera 3 To adjust the tilt position grip the camera platform accessible through the camera viewing slot as shown and move This adjustment provides tilt up down See Addendum 3 for zoom cam set up 1 Hemisphere removal 2 Camera pan adjustment 6 x ...

Страница 16: ...g 16 to the top of the dome The table below details the flying lead functions Electrical connections Red 24Va c live Blue 24Va c neutral P S U Connection diagram Co ax Video Multicore cable with integral Co ax Video Yellow not used Green not used Co ax Screen BNC screen Co ax Signal BNC centre pin 2050 coax operation manual Addendum 2 Type 2050 FA Fixed Attitude Electrical Connections ...

Страница 17: ...ween the preset positions Follow the relevant controller instructions to setup Patrol 1 Patrol mode is cancelled with any manual zoom action 5 Video level adjustment Video level is factory set but can be adjusted by turning VR1 located just above the link A on the receiver board see opposite This adjustment may be required to lighten darken the picture depending on the dis tance of co ax required ...

Отзывы: