5. Adjust amperage (150 to 200 mA) to give 34,5 bar reading on the proportional
valve gage port. Back out zero screw (24) and adjust screw (9) until output flow is at
zero stroke position. Lock both adjustments in place.
6. Increase amperage to 390 mA. Pump should go to full stroke. Set max. volume
screw on opposide control cap for full stroke. Gage in proportional valve gage port
should read approximately 18,6 bar.
7.
If pump fails to go towards full stroke, or fails to go towards zero stroke, differential
pressure may be improperly adjusted. Re-adjust the screw (15 figure 6) out to go
towards full or in to go towards zero flow.
8. Increase and decrease the amperage between 0 and 390 mA several times at
approximately 34,5 bar, 207 bar and 414 bar system pressure. Pump stroke should fol-
low amperage smoothly and proportionally. Full to zero or zero to full stroke should be
achieved in .5 second. Adjust amperage up to 275 mA from zero stroke, then adjust
down from full stroke to 275 mA. The flows at the two 275 mA settings shall not vary
more than 18.9 l/m from each other.