![Denison Hydraulics P05 Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/denison-hydraulics/p05/p05_service-information_2480231015.webp)
ELECTRIC STROKER
CONTROL CAP DISASSEMBLY
ASSEMBLY
PARTS LIST FOR FIGURE 7
control cap assembly S22-15325
15
FIGURE 7
CONTROL CAP ASSEMBLY
ITEM
DESCRIPTION
PART NO.
QTY.
1
Control Cap
032-91842
1
2
Plug
449-00015
1
3
O-ring, 70 S-1 ARP 115
671-00115
1
4
Screw, M16 -2 x 80
311-50001
1
5
Nut
032-91822
1
6
Plug
488-35018
1
7
O-ring 90 S-1 ARP 908
691-00908
1
1. See Figure 7. Remove cover (5) and Max. volume screw (4).
2. Remove 4 screws holding cap to pump.
3. Remove cap assembly from pump.
1. Install O-rings on interface between cap and pump control pad. Install cap on pump
housing as indicated on the applicable view, guiding the control piston into the bore.
2. Torque the assembly bolts to 75 ft-lbs, 102 N m.
3. Install screw (4) in cap. Install O-ring (3) on nut (5). Install nut (5) on screw.
3. Adjust screw till pump is slightly on stroke and lock nut (5).
4. Install O-ring (7) on plug (6). Install plug in nut (5). Torque plug (6) to 50 ft-lb, 68 N m.
torque
50 ft-lb.,
68 Nm
www.comoso.com
Содержание P05