Denios bio.x T700 Скачать руководство пользователя страница 3

User Manual 

 

 

 bio.x T700 160416 

Page 3 of 15   

Issued 10/2010 

 

1. Safety instructions 

This user manual has been created for the parts cleaning unit bio.x T700. It contains all details needed regarding 
correct commissioning, proper operation and maintenance. The instructions in this user manual must be 
carefully followed and adhered to. 

If the instructions are strictly followed in accordance with the user manual, we accept liability within the scope of 
our conditions for guarantees. 

National regulations and safety regulations must be observed

No changes, extensions or modifications may be made to the product without the manufacturer's 
authorisation. No liability is accepted for changes made without the manufacturer's authorisation with the 
warranty ceasing to be valid in such a case. 
 

If you have any further questions, please contact us on our service hotline on 0800 - 753-000-2. 

This unit can only be used safely if you read this user manual carefully and strictly follow the instructions it 
contains. This user manual is an integral part of this unit and must be available to the personnel who 
operate the unit at all times.

 

Such staff must be familiarised with the user manual with particular attention being paid to prohibitions and 
hazard warnings. 

The mains supply connection has to be in accordance with the corresponding regulations (VDE 01000 - 
Association of German Electricians). For safety reasons, the device may only be operated when if a Residual 
Current protective Device (RCD) with a release current of 30 mA is connected in series. 

Please get it checked 

by a qualified electrician. 

In accordance with the German BGV A3, electrical equipment has to be examined in regular intervals. 

The device must be placed horizontally on a stable surface. 

 

Detergents which contain highly flammable substances must not be used. 

Use only detergents 

approved by DENIOS for this unit.  

 

2. Technical Data 

Dimensions (W x D x H) 

1100mm x 910mm x 1725mm 

Total height with open hood 

2400 mm 

Net weight 

approx. 80 kg 

Power consumption 

1.1 kW (when heating turned on) 

Electrical connection 

1/N/PE 230V

 

Back-up fuse on site 

min 10 A 

Working height 

950 mm 

Load capacity  

200 kg 

Tank 

material PE LD 

Maximum fill capacity 

120l 

Minimum fill capacity 

60l

 

Usable work surface 

750-900 mm x 550 mm 

Heating system 

Stainless steel (1.4541) tubular heating element output 1 kW  

Level switch 

Minimum fill level (approx. 55l) 

Temperature sensor 

default setting is 41°C  

Pump  

approx. 240l/h 

 

approx. 6 bar 

Sound pressure level  

< 70 dB (A) 

The function of the demister requires a compressed air connection. 

Input pressure, 6 -8.5 bar 

Pumping capacity 350 l/min 

Содержание bio.x T700

Страница 1: ...hmer Stra e 58 66 D 32549 Bad Oeynhausen Phone 49 0 5731 7 53 122 Fax 49 0 5731 7 53 95 951 Email customerservice denios de You can find your local contact person on our Internet site www denios com 0...

Страница 2: ...tors on the display 8 6 Operation 8 6 1 Energy saving mode 9 6 2 Controllable pump run time 9 7 Maintenance 10 7 1 Filter 10 7 2 Filling level 10 7 3 Suction filter 6 10 7 4 Cleaning fluid 10 7 5 Fine...

Страница 3: ...n being paid to prohibitions and hazard warnings The mains supply connection has to be in accordance with the corresponding regulations VDE 01000 Association of German Electricians For safety reasons...

Страница 4: ...rane pump with dry operation protection operating pressure approx 6 bar flow rate 4 l min 160253 8 Foot switch button optional For turning the cleaning function and the demister On and Off 150097 9 On...

Страница 5: ...nt pane Polycarbonate scratch proof coated Surround seal lock and reach through gauntlet gloves Item Designation Mat No 24 Hood with transparent pane sealing hook rails 189654 25 Reach through gauntle...

Страница 6: ...User Manual bio x T700 160416 Page 6 of 15 Issued 10 2010 1 13 10 24 9 23 16 12 21 26 27 24 28 30 8 15 19 20 25 18 17 16 22 6 3 6 Cleaning position Operating position 2 5 4 7 11...

Страница 7: ...mains On will be shown on the display for 3 seconds The heating system switches on automatically The warming up process can take up to 2 5 hours depending on the initial temperature The operating tem...

Страница 8: ...Close the cover If necessary turn on the light with the on off switch 9 You can also switch on off 30 the demister unit of the transparent hood Reach for the cleaning equipment through the gauntlets...

Страница 9: ...ssing the multi function button for a short time After the energy saving mode has been terminated the unit heats the cleaning fluid up to 41 C The warm up stage takes about an hour depending on the am...

Страница 10: ...sits If the suction filter is so dirty that it can no longer be cleaned in this way it has to be replaced 7 4 Cleaning fluid The cleaning fluid has to be replaced if there is a significant fall in the...

Страница 11: ...s 4 x 5 litre canisters 187609 Cleaning fluid bio x 20 litre canister 130032 Cleaning fluid bio x 200 litre drum 161524 Set for initial filling and refills 5 x 20 litre canisters 130030 7 8 Replacemen...

Страница 12: ...torage area on the back wall of the upper part can be connected without tools 161640 Perforated metal insert To protect the work surface of the cleaning table Makes it possible to work without tilting...

Страница 13: ...connected or is faulty 2 Fuse faulty 1 Connect aerator replace if necessary 2 Replace fuse F 4 Level switch not working Level switch not connected Connect level switch F 5 Short circuit in level swit...

Страница 14: ...User Manual bio x T700 160416 Page 14 of 15 Issued 10 2010 11 Circuit diagram of the electric control unit...

Страница 15: ...eclare that the product type Parts Cleaner bio x T700 complies with the following directives EC Directives 2006 42 EC 2004 108 EC Applied harmonized standards EN 349 EN 12100 1 2 EN 60204 1 EN 12981 1...

Отзывы: