bio.x C500 135147
Page 3 of 12
07/2008
2. Safety instructions
This unit can only be used safely if you read this user manual carefully and strictly follow the instruc-
tions it contains. This user manual is an integral part of this unit and must be available to the person-
nel who operate the unit at all times.
Such staff must be familiarised with the user manual with particular attention being paid to prohibitions
and hazard warnings.
The mains supply connection has to be in accordance with the corresponding regulations (VDE 01000 -
Association of German Electricians). For safety reasons the equipment must be only operated, if a Resid-
ual Current protective Device (RCD) with a release current of 30 mA is connected upstream.
This must be checked by a qualified electrician.
In accordance with the German BGV A3 electrical equipment has to be examined in regular inter-
vals.
The equipment must be set up on a suitable stable, level surface.
Detergents which contain highly flammable substances must not be used. Use only detergents ap-
proved by DENIOS for this unit.
3. Technical data
Dimensions
1010 x 785 x 1140 mm
Net weight
55 kg
Power consumption
1.1 kW
Electrical connection
1/N/PE 230V
∼
Pre-fusing 10
A
Work surface height
950 mm
Load capacity
250 kg
Tank LDPE
Maximum fill capacity
100 l
Minimum fill capacity
60 l
Usable work surface
930 x 545 mm
Heater
Stainless steel (1.4541) heating element output 1 kW
Level switch
Minimum fill level (approx. 60 l)
Operating temperature
Set at 41°C in the factory
Pump, flow rate
approx. 200 l/h