background image

 

 
 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 

 

I-1205 
Rev. B-43

Item

 

N

1

 

2

 

3

 

4

 

5

 

6

 

Nitro

 

Plus

 

Pump

 

Mod

sanitizer

 

c

816 

Nitro

 

Plu

No.

 

Control

 

Mod

dule

 

Kits

 

inclu

heck

 

valves

 

a

 3/23/20

us

 

Control

 

M

DEMA

 

Kit

81.118.

84.65.3

81.118.
81.118.
81.118.

81.144

ule

 

include

 

p

ude

 

side

 

mod

and

 

necessary

018 

odule

 

Replac

t

 

No.

 

.43

 

32

 

.40

 

.41

 

.18

 

4.1

 

rewired

 

pow

ule

 

joints,

 

pre

y

 

pickup

 

and

 

d

cement

 

Kits

 

(

Nitro

 

Plus

 

C

Detergent

 

P

Detergent

 

V

Rinse

 

Modu

Sanitizer

 

Pu

Side

 

Modul

er

 

and

 

trigge

ewired

 

with

 

c

discharge

 

tub

Deterg

Deterge

includes

 

mod

D

Control

 

Modu

Pump

 

Module

Valve

 

Module

ule

 

Kit

 

ump

 

Module

 

K

e

 

Joint

 

r

 

cables

 

and

 

4

cable,

 

necess

bing.

 

gent Pump or 

ent Valve type

Page 

dule

 

mountin

Description

 

ule

 

e

 

Kit

 

e

 

Kit

 

Kit

 

4

 

side

 

module

ary

 

pump

 

or

 

10 of 13

ng

 

pins)

 

e

 

joints.

 

valve

 

fittings

 

,

 

rinse

 

or

 

Содержание Nitro Plus

Страница 1: ...nsin and a TIVE CLOTHING A Nitro hemical er designed to achine The Nit meet all applic vincial or other lectrical contra certified elect al plumbing co to be installed any other state G AND EYEWEA Plu...

Страница 2: ...er Board M Magnetic Field Sensor Packing Kit List Nitro Plus Installation Kit Part Number Description Qty Model NP DL T NP LL T NP DLL T NP LLL T 904 8T Rinse Check Valve Stainless Steel 1 1 1 1 904 8...

Страница 3: ...Rinse Sanitizer Pump Rate 0 5oz min 15ml min Operating Temp 4 30 C 40 100 F Case Material ABS Weight 3 8 kg 8 5 lbs Max Altitude 2000 M 6500 ft Environmental Temp 0 40 C 32 104 F Installation Categor...

Страница 4: ...which is cle uired and if de eded to go from uired to reach th hine p to install the ty purposes di Nitro Plus Co mmendations OUNDED EA he proper wirin unction with D llowing steps w grammed in th F D...

Страница 5: ...wires to the appropriate rinse trigger output between 24 and 480 V 50 60 Hz as recommended by the dish machine manufacturer 3 Make sure to connect the earth ground green wire to the ground connection...

Страница 6: ...min Initial Charge 1s 10 min Press Press Press Alarm Delay 5s 10 min Charge Activate Off 60s Charge Clock 5 min 16 hrs Press Initial Charge Activate will determine the length of the rinse trigger tha...

Страница 7: ...Charge Clock 5 min 16 hrs Press Initial Charge Activate will determine the length of the rinse trigger that instigates an initial charge while in probe less mode Charge Clock If no triggers are receiv...

Страница 8: ...I 1205 Rev B 43816 Page 8 of 13 3 23 2018 Replacement Parts and Reference Information...

Страница 9: ...t trigger board to control board 2pcs in kit 11 81 163 1 Power Switch 12 81 18 1 6 x 3 8 Hi Lo Screw for plastic 13 81 181 2 Probe Cable 14 84 176 1 Strain Relief 15 81 19 1 8 Flat Head Screw 16 81 20...

Страница 10: ...2 40 41 18 4 1 rewired pow ule joints pre y pickup and d cement Kits Nitro Plus C Detergent P Detergent V Rinse Modu Sanitizer Pu Side Modul er and trigge ewired with c discharge tub Deterg Deterge in...

Страница 11: ...1 2 Hole Plug not shown plugs unused 1 2 holes on back of enclosures 9 81 118 15 Detergent Pump Kit Blue Pump Parts Roller Block Assy no motor 10 25 85 19 10 32 x 2 Stainless Steel Screw Rinse Sanitiz...

Страница 12: ...e Detergent Silicone 81 177 2 Squeeze Tube Rinse Sani EPDM Default squeeze tube with Nitro Plus 81 177 22 Squeeze Tube Rinse Sani Silicone 81 182 1 1 4 x 1 4 Push On Union JG connects pickup discharge...

Страница 13: ...te 2 Check the probe cable connection points and make sure it is connected properly 3 Clean Probe 4 Check set point in programming Pump under feeding 1 If in concentration or probe mode the probe cabl...

Отзывы: