I-1022
Page 6 of 8
Rev. B-36992 6/17/11
PRO
BELESS
Potentiometers (Knobs)
The potentiometers can be set according to the following charts. Each of the next four figures will outline various
configurations that are possible. For more information on these configurations consult pages 5-6 to see how to set up the
dip switches for the configurations.
Rinse/Sanitizer Settings
The Rinse and Sanitizer knobs control the same
setting whether in probe or probeless mode and in
door or conveyor mode. They control the speed of
the rinse and sanitizer pump.
The table to the right has approximate values for
the pump rate at different settings of the knob.
Only the DLL and LLL models have a sanitizer
potentiometer.
Probeless and Door Configuration
Initial Detergent Charge –
The detergent knob sets the time the
detergent pump will run or detergent valve will remain open during an
initial charge. The time can be set from 0-60 sec.
The initial charge is activated in one of two ways.
1.
It can be activated by 1 hour of elapsed time where no triggers have
activated the dispenser.1
2. With the rinse limit turned on (switch 7)
and a rinse trigger active
for
Detergent
more than 20 seconds, an initial charge will be dispensed.
Dead Cycles –
The alarm knob sets the number of cycles no detergent is
dispensed before a recharge portion of detergent is added to the machine.
The table to the right has the different settings for the Dead Cycle count
corresponding to the knob setting.
CON
C
EN.
MODE
PLUS 4 SEC
RINSE DELAY
20 SECON
D
RINSE LIMIT
ON
1
6
7
ON
O
O
O
PRESS SWITCH THIS
WAY FOR ON
O
O
O
PRESS SWITCH THIS
WAY FOR OFF
1
6
7
OFF
O
F
F
A
LARM VOL
HIGH
5
8
2
3
4
O
O
O
O
O
O
O
O
O
O
5
8
2
3
4
PLUS 2 SEC
RINSE DELAY
CONVEY
OR
MODE
HIGH RAN
G
E
PULSE FEED
ON
MODE
DOOR M
O
DE
NORMAL
RANGE
PULSE FEED
OF
F
RINSE
DELAY
PLUS 0 SEC
PLUS 0 SEC
RINSE
DELAY
RINSE LIMIT
OF
F
ALARM VO
L
LOW
RINSE/
SANITIZER
SETTING
0
0 ml/min
0 oz/min
2
46 ml/min
1.5 oz/min
4
58 ml/min
1.96 oz/min
6
62 ml/min
2.1 oz/min
8
66 ml/min
2.25 oz/min
10
68 ml/min
2.3 oz/min
PUMP RATE
Rinse
DETERGENT
0-60 sec
0-235 ml
0-8 oz
INITIAL
CHARGE
SETTING
6
5
8
9
10
3
0
4
7
1
2
Alarm (Dead Cycles)
ALARM
SETTING
DEAD
CYCLES
2
0
4
1
6
2
8
3
6
5
8
9
10
3
0
4
7
1
2
50%