background image

I-1022 

 

Page 6 of 8 

Rev. B-36992      6/17/11 

PRO

BELESS 

 

 
 
Potentiometers (Knobs) 

The potentiometers can be set according to the following charts. Each of the next four figures will outline various 
configurations that are possible. For more information on these configurations consult pages 5-6 to see how to set up the 
dip switches for the configurations.  

 

Rinse/Sanitizer Settings

 

The Rinse and Sanitizer knobs control the same 
setting whether in probe or probeless mode and in 
door or conveyor mode. They control the speed of 
the rinse and sanitizer pump.  
 
The table to the right has approximate values for 
the pump rate at different settings of the knob.  

 

    Only the DLL and LLL models have a sanitizer  
    potentiometer.                                                                                                                                                 

 

Probeless and Door Configuration 

 

Initial Detergent Charge – 

The detergent knob sets the time the 

detergent pump will run or detergent valve will remain open during an 
initial charge. The time can be set from 0-60 sec. 
 
The initial charge is activated in one of two ways.  

1.

 

It can be activated by 1 hour of elapsed time where no triggers have 
activated the dispenser.1 

    2. With the rinse limit turned on (switch 7)

 

and a rinse trigger active 

for  

Detergent 

 

more than 20 seconds, an initial charge will be dispensed.  

     
 

Dead Cycles –

 The alarm knob sets the number of cycles no detergent is 

dispensed before a recharge portion of detergent is added to the machine. 
 
The table to the right has the different settings for the Dead Cycle count 
corresponding to the knob setting. 

 
 

 

CON

C

EN. 

MODE

 

PLUS 4 SEC 

RINSE DELAY

 

20 SECON

RINSE LIMIT 

ON 

1

 

6

7

ON

 

O

 

O

O

PRESS SWITCH THIS 
WAY FOR ON

 

O

 

O

O

PRESS SWITCH THIS 
WAY FOR OFF

1

 

6

7

OFF

 


F

 

A

LARM VOL 

HIGH

 

5

8

2

 

3

 

4

 

O

O

O

 

O

 

O

 

O

O

O

 

O

 

O

 

5

8

2

 

3

 

4

 

PLUS 2 SEC 

RINSE DELAY

 

CONVEY

OR 

MODE

 

HIGH RAN

G

E

 

PULSE FEED 

 

ON

 

MODE 

DOOR M

O

DE

 

NORMAL 

RANGE

 

PULSE FEED 

OF

F

 

RINSE 

DELAY

 

PLUS 0 SEC 

PLUS 0 SEC 

RINSE 

DELAY

 

RINSE LIMIT 

OF

F

 

ALARM VO

LOW

 

RINSE/ 

SANITIZER 

SETTING

0

0  ml/min

0 oz/min

2

46 ml/min

1.5 oz/min

4

58 ml/min

1.96 oz/min

6

62 ml/min

2.1 oz/min

8

66 ml/min

2.25 oz/min

10

68 ml/min

2.3 oz/min

PUMP RATE

            Rinse 

DETERGENT 

0-60 sec

0-235 ml

0-8 oz

INITIAL 

CHARGE 

SETTING

  8 

      
  9 

 10 

  

  1 

 2 

Alarm (Dead Cycles) 

ALARM 

SETTING

DEAD 

CYCLES

2

0

4

1

6

2

8

3

  8 

      
  9 

 10 

  

  1 

 2 

50%

Содержание Master Nitro Express

Страница 1: ...products must meet all applicable electrical codes and regulations established by national city county parish provincial or other agencies It is possible that electrical codes and regulations require...

Страница 2: ...VALVE COMP X 1 8 NPT KYNAR X X 81 16 1 TIE WRAPS 8 LONG 5 5 8 8 I1022 INSTRUCTION SHEET X X X X Operational Requirements For indoor use only Main Power 100 265VAC 50 60 Hz 1 5A Motor Solenoid Rating...

Страница 3: ...CT 81 118 29 1 PUMP 2 SPRING ROLLER 60 RPM MOTOR ID KIT 80 59 60MK 60 RPM DETERGENT MOTOR 3 44 123 14B DM NITRO EXPRESS DETERGENT VALVE REPLACEMENT 81 118 29 2 PUMP 3 ROLLER FIXED 15 RPM MOTOR 1 8 ID...

Страница 4: ...tall the sanitizer injection fitting 904 8KY if sanitizer is used into the rinse line tap provided by the manufacturer of the machine If a tap is not provided follow the manufacturer s recommendations...

Страница 5: ...am for the unit This is the internal wiring of the unit Programming the Nitro Express Programming is done through the setting of dip switches and potentiometers knobs The following states how to progr...

Страница 6: ...of elapsed time where no triggers have activated the dispenser 1 2 With the rinse limit turned on switch 7 and a rinse trigger active for Detergent more than 20 seconds an initial charge will be disp...

Страница 7: ...The settings for the probe configuration are the same when the dispenser is being used in door or conveyor mode Detergent Concentration Level The detergent knob sets the concentration level or set poi...

Страница 8: ...ble connection points and make sure it is connected properly 3 Clean Probe 4 Switch dip switch to low range or set knob to needed setting Pump under feeding 1 If in concentration or probe mode the pro...

Отзывы: