DEMA® MODEL 693T FOAM STATION II 

INSTALLATION INSTRUCTION 

I-747 

 

 

Page 6 of 8 

Rev. E-40261 

 

 

11/13/14 

 
 

NO. PART 

NO. 

DESCRIPTION 

1 100-38 

Strainer 

Washer 

2 65-10 

Swivel 

Coupling 

65-14 

Hose Fitting – Medium Long 

4 69-8-2 

Top 

Manifold 

66-153 

Pipe Plug & O-Ring Assy.  

6 99-8-2 

Valve 

7 69-2 

Adapter 

8 30-5-14 

O-Ring 

(EP) 

58-83-1 

Pipe Adapter (3/8”) 

10 69-9-1 

Adapter 

11 69-4 

Bottom 

Manifold 

12 65-18-1 

Outlet 

Fitting 

13 93-15-2 

Pressure 

Gauge 

14 

25-137-12 

¼” NPT Nipple X 1 ½ Lg. 

NO. PART 

NO. 

DESCRIPTION 

15 

16-11 

¼” NPT Ball Valve 

16 

24-11L 

Foot Strainer (For 3/8” ID Tubing) 

17 

24-11MP 

Foot Strainer (For 1/4” ID Tubing) 

18 

61-107 

Ceramic Weight (3/8” ID Tubing) 

19 

61-107-2 

Ceramic Weight (1/4” ID Tubing) 

20 

100-12 

Vinyl Tubing (1/4” ID X 8’ Lg.) 

21 

100-12L 

Vinyl Tubing (3/8” ID X 8’ Lg.) 

 
 

ACCESSORIES 

NO. PART 

NO. 

DESCRIPTION 

22 

93-18 

Plastic Foam Wand 

23 

93-14  

3/4” ID X 25’ Lg. Outlet Hose 

ACCESSORY

13

8

14

20 21

15

16

17

1

FOAMER ASSEMBLY 
(SHOWN EXPLODED
ON PAGE 8)

19

18

6

9

8

7

2

3

6

4

23

22

12

11

8

P203CTC

(SHOWN EXPLODED 

ON PAGE 7)

8

10

6

5

Содержание 693T FOAM STATION II

Страница 1: ...hillip screwdriver into the anchors for the keyhole slots so the screw heads are sticking out of the wall approximately Mount the unit by inserting the screw heads through the keyhole slots and tighte...

Страница 2: ...AND LENGTH MIN PRESSURES WATER AIR 25 OF ID 40 PSI 40 PSI 50 OF ID 50 PSI 40 PSI 25 OF ID 60 PSI 40 PSI TABLE 2 Foamer Injection Rate Metering Tip Color Injection Rate for Viscosities Shown 1 cps 75...

Страница 3: ...Station permits the operator to select a chemical to foam left hand lever or a chemical to spray right hand lever or a clear water rinse middle lever by opening and closing the appropriate valve with...

Страница 4: ...ze See Table 1 7 Air supply is inadequate Increase air pressure by regulating up 8 Detergent is wrong Use a more effective detergent and be sure that product is recommended for foaming 9 Using an oile...

Страница 5: ...ge caused by chemicals corrosion improper voltage supply physical abuse or misapplication Rubber and synthetic rubber parts such as O rings diaphragms squeeze tubing and gaskets are considered expenda...

Страница 6: ...g 13 93 15 2 Pressure Gauge 14 25 137 12 NPT Nipple X 1 Lg NO PART NO DESCRIPTION 15 16 11 NPT Ball Valve 16 24 11L Foot Strainer For 3 8 ID Tubing 17 24 11MP Foot Strainer For 1 4 ID Tubing 18 61 107...

Страница 7: ...2 100 15 Metering Tip Specify Color 3 24 62 SP Metering Knob Kit 4 24 25S O Ring Silicone 5 24 24P Check Valve Ball 6 24 23 2 Check Valve Spring Hasteloy 7 24 37 7 Check Valve Core 8 25 29S O Ring Sil...

Страница 8: ...12 23 9 2 Check Valve Spring Hasteloy 13 23 10 Ball 9 32 Dia S S 14 23 11V Check Valve O Ring Viton 15 23 32T Metering Knob NO PART NO DESCRIPTION 16 61 9 Metering Tip Specify Color 17 30 5V 14 O Rin...

Отзывы: