background image

 

DEMA® MODEL 693T FOAM STATION II 

INSTALLATION INSTRUCTION 

I-747 

 

 

Page 3 of 8 

Rev. E-40261 

 

 

11/13/14 

 

Table 3: P203CAM Injector Injection Rate 

Metering 

Tip Color 

Injection Rate for Viscosities Shown 

1 cps 

75 cps 

200 cps 

Oz/Gal Ratio Oz/Gal  Ratio  Oz/Gal Ratio 

Tan

 

0.40

 

320-1

 

0.25

 

512-1

 

0.20

 

640-1

 

Orange

 

0.50

 

256-1

 

0.35

 

366-1

 

0.25

 

512-1

 

Turquoise

 

0.75

 

171-1

 

0.45

 

284-1

 

0.35

 

366-1

 

Pink

 

0.95

 

135-1

 

0.65

 

197-1

 

0.45

 

284-1

 

Light Blue*

 

1.30

 

98-1

 

0.80

 

160-1

 

0.55

 

233-1

 

Brown

 

1.50

 

85-1

 

0.90

 

142-1

 

0.60

 

213-1

 

Red

 

1.90

 

67-1

 

1.00

 

128-1

 

0.70

 

183-1

 

White

 

2.25

 

57-1

 

1.30

 

98-1

 

0.80

 

160-1

 

Green

 

2.64

 

49-1

 

1.50

 

85-1

 

0.90

 

142-1

 

Blue

 

3.20

 

40-1

 

1.75

 

73-1

 

1.00

 

128-1

 

Yellow

 

4.85

 

26-1

 

2.25

 

57-1

 

1.10

 

116-1

 

Black

 

6.50

 

20-1

 

2.40

 

53-1

 

1.15

 

111-1

 

Purple

 

9.20

 

14-1

 

2.70

 

47-1

 

1.20

 

107-1

 

Gray

 

10.40

 

12-1

 

2.85

 

45-1

 

1.25

 

102-1

 

No Tip

 

12.80

 

10-1

 

3.50

 

37-1

 

1.55

 

83-1

 

* Metering tip color was formerly clear. 

All injection rates are based on 40 PSI inlet water pressure and a water flow rate of 2.5 GPM.

 

 
 
 

 

4.   OPERATION: 

The 693T Foam Station permits the operator to select a chemical to foam (left hand lever), or a chemical to spray (right hand 
lever) or a clear water rinse (middle lever) by opening and closing the appropriate valve with its lever.  

ONLY ONE 

VALVE SHOULD BE OPEN AT ANY TIME.

  If two valves are opened simultaneously, the injector will not draw 

chemical. 
 

NOTE:

  When using the spray wand, make sure that the shut-off valve at the end of the hose is in the fully open position in 

order to draw chemical product.   
 

To Foam: 
First

:  Open the left hand lever all the way.  Water rushing through the foamer will draw up soap and send soapy water 

through the hose. 

 
Next

: Pull out on the air regulator knob above the air gage.  Set the air regulator to 40psi.  Open the air valve on the left side 

of the 693T.  Adjust the air regulator upwards gradually until you obtain the thickness of foam you desire.  Push the air 
regulator knob back in to lock the setting in place.  This operation must be repeated in the same order each time the 693T is 
shut down and restarted (water first then gradually build up air pressure). 

 

 

TABLE 4: Water Flow & Air Flow Setting. 

 

PRESSURE (PSI) 

 

40 50 60 80 

WATER FLOW (GPM) 

1.4 1.6 1.7 2.1 

AIR FLOW (SCFM) 

3.5 4.2 4.8 6.1 

 
 
 

Содержание 693T FOAM STATION II

Страница 1: ...hillip screwdriver into the anchors for the keyhole slots so the screw heads are sticking out of the wall approximately Mount the unit by inserting the screw heads through the keyhole slots and tighte...

Страница 2: ...AND LENGTH MIN PRESSURES WATER AIR 25 OF ID 40 PSI 40 PSI 50 OF ID 50 PSI 40 PSI 25 OF ID 60 PSI 40 PSI TABLE 2 Foamer Injection Rate Metering Tip Color Injection Rate for Viscosities Shown 1 cps 75...

Страница 3: ...Station permits the operator to select a chemical to foam left hand lever or a chemical to spray right hand lever or a clear water rinse middle lever by opening and closing the appropriate valve with...

Страница 4: ...ze See Table 1 7 Air supply is inadequate Increase air pressure by regulating up 8 Detergent is wrong Use a more effective detergent and be sure that product is recommended for foaming 9 Using an oile...

Страница 5: ...ge caused by chemicals corrosion improper voltage supply physical abuse or misapplication Rubber and synthetic rubber parts such as O rings diaphragms squeeze tubing and gaskets are considered expenda...

Страница 6: ...g 13 93 15 2 Pressure Gauge 14 25 137 12 NPT Nipple X 1 Lg NO PART NO DESCRIPTION 15 16 11 NPT Ball Valve 16 24 11L Foot Strainer For 3 8 ID Tubing 17 24 11MP Foot Strainer For 1 4 ID Tubing 18 61 107...

Страница 7: ...2 100 15 Metering Tip Specify Color 3 24 62 SP Metering Knob Kit 4 24 25S O Ring Silicone 5 24 24P Check Valve Ball 6 24 23 2 Check Valve Spring Hasteloy 7 24 37 7 Check Valve Core 8 25 29S O Ring Sil...

Страница 8: ...12 23 9 2 Check Valve Spring Hasteloy 13 23 10 Ball 9 32 Dia S S 14 23 11V Check Valve O Ring Viton 15 23 32T Metering Knob NO PART NO DESCRIPTION 16 61 9 Metering Tip Specify Color 17 30 5V 14 O Rin...

Отзывы: