DEMA MODEL 692T FOAM STATION I
INSTALLATION INSTRUCTION
I-719
Page 1 of 6
Rev. D-31918
12/22/05
1.
PARTS CHECKLIST:
ITEM DESCRIPTION
QTY.
A.
Foam Station Assembly
1
B.
#10 Screw & Anchor Kit Set (Total: 4 Screws & 4 Anchors)
1
C.
Ceramic Weight
1
D.
¼” ID Tubing & Foot Valve Assembly
1
E.
Metering Tip Kit (P/N 61-9K)
1
F.
Label Card
1
2.
INSTALLATION:
This product is designed only to be used as described in this instruction sheet. Adhere to all warnings and
cautions identified in this document.
WARNING:
Installations must conform to all local and national plumbing codes and use
approved backflow prevention and pressure relief devices where required.
ALWAYS DISCONNECT DISPENSER FROM WATER SOURCE WHEN DISPENSER
IS NOT IN USE.
Always read SDS for all chemicals used and follow personal protective guidelines.
A. Mounting and Water Supply:
Locate mounting holes on a permanent vertical wall. Drill all holes into the drywall using a ¼” diameter bit for use with the
included #10 screw and anchor set. (If mounting unit to wood and you do not plan to use the included anchors, drill 1/8”
diameter holes.) Insert the anchors into drilled holes and hammer them into the wall until they are flush with face of wall.
Assemble the #10 screws with a phillip screwdriver into the anchors for the keyhole slots so the screw heads are sticking out
of the wall approximately ½”. Mount the unit by inserting the screw heads through the keyhole slots and tightening the
screws. Secure the unit by inserting screws into the lower 2 holes.
The water inlet is equipped with a female garden hose fitting. The fitting may be removed to permit direct connection to
3/8” NPT pipe.
Note: Apply pipe dope, hand tighten, and then turn 1-1/2 times with a wrench.
DO NOT OVER
TIGHTEN.
WARNING: Do not use Teflon tape to seal internal plastic threads as the extra thickness of the tape may cause the
plastic to crack. Use non-welding liquid sealant instead.
WARNING: Water supply should not exceed 125 psi and water temperature must not exceed 150°F.
B. Outlet Connection:
Connect the discharge hose to the garden hose fitting.
NOTE: Be sure to clamp garden hose onto wall approximately 1
ft. below the unit, (Clamps, screws, & anchors are not supplied.)
Attach shut-off valve to the discharge end of the hose.
See Table 1 for hose limitations.
TABLE 1: Outlet Garden Hose Connection
GARDEN HOSE SIZE AND
LENGTH
MIN. PRESSURES
WATER
AIR
25’ OF ¾” ID
40 PSI
40 PSI
50’ OF ¾” ID
50 PSI
40 PSI
25’ OF ½” ID
60 PSI
40 PSI