background image

DEMA MODEL 692T FOAM STATION I 

INSTALLATION INSTRUCTION 

I-719 

 

 

Page 1 of 6 

Rev. D-31918 

 

 

12/22/05 

 

1.

 

PARTS CHECKLIST: 

 

ITEM DESCRIPTION 

QTY. 

A.

 

 

Foam Station Assembly 

B.

 

 

#10 Screw & Anchor Kit Set (Total: 4 Screws & 4 Anchors) 

C.

 

 

Ceramic Weight 

D.

 

 

¼” ID Tubing & Foot Valve Assembly 

E.

 

 

Metering Tip Kit (P/N 61-9K) 

F.

 

 

Label Card 

 

2.

 

INSTALLATION: 

This product is designed only to be used as described in this instruction sheet.  Adhere to all warnings and 
cautions identified in this document.   

WARNING: 

Installations must conform to all local and national plumbing codes and use 

approved backflow prevention and pressure relief devices where required. 
 

ALWAYS DISCONNECT DISPENSER FROM WATER SOURCE WHEN DISPENSER 
IS NOT IN USE. 

Always read SDS for all chemicals used and follow personal protective guidelines.

 

 
A.  Mounting and Water Supply: 

Locate mounting holes on a permanent vertical wall.  Drill all holes into the drywall using a ¼” diameter bit for use with the 
included #10 screw and anchor set.  (If mounting unit to wood and you do not plan to use the included anchors, drill 1/8” 
diameter holes.)  Insert the anchors into drilled holes and hammer them into the wall until they are flush with face of wall. 
Assemble the #10 screws with a phillip screwdriver into the anchors for the keyhole slots so the screw heads are sticking out 
of the wall approximately ½”.  Mount the unit by inserting the screw heads through the keyhole slots and tightening the 
screws.  Secure the unit by inserting screws into the lower 2 holes. 
 
The water inlet is equipped with a female garden hose fitting.  The fitting may be removed to permit direct connection to 
3/8” NPT pipe. 

 Note: Apply pipe dope, hand tighten, and then turn 1-1/2 times with a wrench.

   

DO NOT OVER 

TIGHTEN. 

 

WARNING:  Do not use Teflon tape to seal internal plastic threads as the extra thickness of the tape may cause the 
plastic to crack.  Use non-welding liquid sealant instead. 
 

  WARNING:  Water supply should not exceed 125 psi and water temperature must not exceed 150°F. 

 

 

B.   Outlet Connection: 

Connect the discharge hose to the garden hose fitting.  

NOTE: Be sure to clamp garden hose onto wall approximately 1 

ft. below the unit,  (Clamps, screws, & anchors are not supplied.)  

Attach shut-off valve to the discharge end of the hose. 

See Table 1 for hose limitations. 
 

TABLE 1: Outlet Garden Hose Connection 

GARDEN HOSE SIZE AND 

LENGTH 

MIN. PRESSURES 

 WATER 

AIR 

25’ OF ¾” ID 

40 PSI 

40 PSI 

50’ OF ¾” ID 

50 PSI 

40 PSI 

25’ OF ½” ID 

60 PSI 

40 PSI 

 