DEMA MODEL 692T FOAM STATION I 

INSTALLATION INSTRUCTION 

I-719 

 

 

Page 3 of 6 

Rev. D-31918 

 

 

12/22/05 

knob back in to lock the setting in place.  This operation must be repeated in the same order each time the 692T is shut down and 
restarted (water first then gradually build up air pressure). 
 

 

TABLE 3: Water Flow & Air Flow Setting 

 

PRESSURE (PSI) 

 

40 50 60 80 

WATER FLOW (GPM) 

1.4 1.6 1.7 2.1 

AIR FLOW (SCFM) 

3.5 4.2 4.8 6.1 

 
 
 
 

5.

 

SERVICING: 

 

 

 

PROBLEM:

 

 

 

 

 

 

SEE SITUATION: 

 

Unit will not draw or stops drawing chemical 

 

1, 2, 3, 5, 6, 10, 11, 12, 13, 15, 16, 17 

 

Poor foam quality 

 

 

 

 

1, 2, 3, 5, 6, 10, 11, 12, 13, 15, 16 

 

Foam surges 

 

 

 

 

 

1, 2, 3, 4, 5, 6, 8, 9, 10, 11, 12, 13, 15, 16 

 

Foam output is too wet 

 

 

 

 

1, 3, 4, 5, 6, 7, 8, 9, 10, 11, 13, 16 

 Foam 

output 

is 

too 

dry 

    2 

 

Water is flowing into chemical container 

 

 

12 

 

Foam does not clean adequately 

 

 

 

4, 8, 11, 14 

 

POSSIBLE SITUATIONS 

Situation Cause 

Solution 

Chemical tube not immersed in chemical 
or chemical depleted. 

Immerse tube in chemical or replace. 

Air pressure is too high for water. 

Adjust air regulator down. 

Water pressure is too low. 

At least 30 psi is required.  Increase if possible, or decrease air pressure. 

Chemical to water ratio is too low. 

Change metering tip to one that is larger. 

Foam hose is kinked. 

Straighten hose. 

Foam hose is too long or wrong size. 

See Table 1. 

Air supply is inadequate. 

Increase air pressure by regulating up. 

Detergent is wrong. 

Use a more effective detergent, and be sure that product is recommended 
for foaming. 

Using an oiler on the airline may 
deteriorate the quality of the foam. 

Use only clean, dry air. 

10 

Holes or cuts are in chemical inlet tube. 

Replace the tube. 

11 

Strainer and/or metering tip are blocked. 

Remove, clean or replace. 

12 

Solution check valve is not working. 

Remove, clean or replace. 

13 

Air regulator is not working. 

Remove, clean or replace. 

14 

Soil has hardened on surface. 

Reapplication may be necessary.  Be sure to rinse foam off before it dries. 

15 

Rust or build-up is clogging the foamer 
aspirator. 

Disconnect water from unit and remove injector from unit.  Visually 
inspect.  Remove blockage. 

16 

Water scale or chemical build-up may 
have formed in the water jets. 

Place the chemical tube in descaling acid and completely open the shut-
off valve.  Let unit run until the chemical tube is filled with acid, then 
close shut-off valve and water supply.  Elevate the chemical tubing and 
outlet hose until acid has had enough time to descale.  Repeat if necessary.  
For severe cases, disassemble unit and soak foamer body in descaling 
acid. 

17 

More than one valve is open. 

Close the rinse valve. 

 