background image

DEMA 151

 

FAUCET PROPORTIONER 

INSTALLATION INSTRUCTIONS

I-101 

 

  Pg. 

of 

Rev. C-41011    9/11/15 

 

IV.

 

CHEMICAL INJECTION ADJUSTMENT 

Chemical feed rates are controlled by metering tips screwed into the proportioner barb.  Select a tip using the Table 
as a guide. 
 

Note: 1cp(centipoise) is equivalent to the viscosity of water, 75 cp is approximately equal to the viscosity of 10 
weight motor oil, and 200 cp is approximately equal to the viscosity of most dishwashing detergents. 
 
 

Metering Tip 

Color 

Injection Rates For Viscosities Shown 

1 cp 

2cp 

75cp 200 

cp 

Oz./Gal. Ratio Oz./Gal.  Ratio Oz./Gal. Ratio  Oz./Gal.  Ratio 

Tan 

0.25 512-1 0.20  640-1 0.17 756-1  0.15  853-1 

Orange 

0.33 384-1 0.30  427-1 0.25 512-1  0.20  640-1 

Turquoise 

0.50 256-1 0.40  320-1 0.33 384-1  0.25  512-1 

Pink 

0.63 205-1 0.50  256-1 0.45 284-1  0.33  384-1 

Clear 

0.75 171-1 0.70  183-1 0.60 213-1  0.45  284-1 

Brown 

1.00 128-1 0.85  151-1 0.70 183-1  0.50  256-1 

Red 

1.25 102-1 1.00  128-1 0.80 160-1  0.60  213-1 

White 

1.50 85-1 1.25 102-1 1.00 128-1 0.70  183-1 

Green 

1.75 73-1 1.50  85-1 1.15 111-1 0.75  171-1 

Blue 

2.00 64-1 1.75  73-1 1.35 95-1  0.85  151-1 

Yellow 

3.20 40-1 2.50  51-1 1.85 69-1  0.95  135-1 

Black 

4.00 32-1 3.20  40-1 2.20 58-1  1.00  128-1 

Purple 

6-40 20-1 5.00  25-1 2.50 51-1  1.05  122-1 

Gray 

10.00 12-1 5.50  23-1 2.75 47-1  1.07  120-1 

No Tip 

12.00 10-1 6.40  20-1 3.20 40-1  1.10  116-1 

 
 

Содержание 151

Страница 1: ...s Screw proportioner directly onto garden hose type faucets Remove inlet adapters for mounting onto standard external aerator threads For other faucets see parts break down for adapter part numbers Select a metering tip See section 4 and screw it into the inlet barb Figure 1 Place the chemical container in a convenient location not more than 6 feet below the proportioner greater lifts will reduce ...

Страница 2: ...CARE WHEN HANDLING HAZARDOUS CHEMICALS Turn on water and press the blue button to draw in chemical When water is turned off proportioner will reset to dispense clear water FIGURE1 METERINGTIP PUSHBUTTON AIRVENT OUTLETSCREENRETAINER SUPPLYTUBING FOOTVALVE CERAMICWEIGHT CHEMICALCONTAINER INLETADAPTER DETERGENTINLETBARB ...

Страница 3: ...atio Oz Gal Ratio Oz Gal Ratio Tan 0 25 512 1 0 20 640 1 0 17 756 1 0 15 853 1 Orange 0 33 384 1 0 30 427 1 0 25 512 1 0 20 640 1 Turquoise 0 50 256 1 0 40 320 1 0 33 384 1 0 25 512 1 Pink 0 63 205 1 0 50 256 1 0 45 284 1 0 33 384 1 Clear 0 75 171 1 0 70 183 1 0 60 213 1 0 45 284 1 Brown 1 00 128 1 0 85 151 1 0 70 183 1 0 50 256 1 Red 1 25 102 1 1 00 128 1 0 80 160 1 0 60 213 1 White 1 50 85 1 1 2...

Страница 4: ...drawing RETURNS NO MERCAHNDISE MAY BE RETURNED FOR CREDIT WITH DEMA S WRITTEN PERMISSION RETURN MERCHANDISE AUTHORIZATION NUMBER REQUIRED IN ADVANCE OF RETURN WARRANTY DEMA products are warranted against defective material and workmanship under normal use and service for one year from the date of manufacture This limited warranty does not apply to any products which have a normal like shorter than...

Страница 5: ...r w Washer 11 100 12 ID x 8 Lg Supply Tubing 12 61 107 2 Ceramic Weight NO PART NO DESCRIPTION 13 100 16E Foot Valve 14 100 51 Repair Kit NO PART NO DESCRIPTION 15 150 23 Outside Chicago Thread Adapter 16 150 21 Inside Aerator Thread Adapter 17 150 32 Inside Kohler Thread Adapter 18 150 9 2 Irregular Faucet Adapter 19 100 14M Coupling For ID x 8 Lg Tubing 20 34 22 Backflow Preventer INTERNAL AERAT...

Отзывы: