LED FLOODLIGHT FITTING INSTRUCTIONS

PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION

LEAVE A COPY FOR THE USER/MAINTENANCE ENGINEER FOR FUTURE REFERENCE

We recommend this fitting is installed by a qualified Electrician.

GUARANTEE

This product is guaranteed in the EU for a period of 5 years from the date of purchase. The guarantee is invalid in the case of improper use, 

installation, tampering, removal of the QC date label, installation in an improper working environment or installation not according to the current 

edition of the IEE Wiring Regulations (BS 7671).  Should this product fail during the guarantee period it will be replaced free of charge, subject 

to correct installation and return of the faulty unit. Déluce Lighting does not accept responsibility for any installation costs associated with the 

replacement of this product. Your statutory rights are not affected. Déluce Lighting reserves the right to alter specifications without prior notice.

IMPORTANT INSTALLATION INFORMATION

1.  Installation should be carried out in accordance with the latest 

edition of the IEE Wiring Regulations (BS7671) and taking into 

consideration the latest Building Regulations. If in doubt, consult a 

qualified electrician.

2.  Important: Ensure that ALL electrical connections are tight with no 

loose strands including factory made connections.

3. 

Before commencing any installation or maintenance work, 

ensure electricity is switched off at the mains.

4.  Please take note of the maximum rated voltage for your floodlight.

  PLEASE NOTE THIS FLOODLIGHT IS MULTI-VOLTAGE - AN 

APPROPRIATE 110V STEP-DOWN TRANSFORMER MUST BE 

USED WHEN USING THE FLOODLIGHT ON SITE.

5.  Please take note of the IP (Ingress Protection) rating of your 

floodlight when deciding location.

6.  Always allow sufficient slack in the supply cable in order to remove 

the floodlight from its position for any future maintenance.

7.  Care must be taken for installations where the lens or bezel may 

come into contact with bare skin.

8.  Please take note of the nearest illuminated surface as detailed on the 

product label.

9. 

Always check whether the site of the installation can 

support the weight of the floodlight. 

  For safety, 1.5 times the weight of the floodlight is 

recommended. If you are unsure do not install.

GENERAL INSTALLATION - SAFETY

1.   Please make sure you are safe when working at height.
2.  Employ the latest safety regulations and procedures to ensure the 

safe installation of this floodlight.

3.  When positioning your floodlight out of doors please take note 

that outdoor electrical installations should be installed by a 

qualified Electrician. Correct circuit protection for all exterior 

electrical services should include a residual current device (RCD), 

also known as an earth leakage circuit breaker (ELCB). This simple 

device ensures that the power is cut off immediately; it detects a 

leakage of current to earth, which indicates an electrical fault which 

is potentially threatening to life. 

 

Observe these few Simple rules and keep your outdoor electrical 

installation safe.

INSTALLATION INSTRUCTIONS

1.   Select the required position for the floodlight. 
2.   Remove the mounting bracket from the floodlight.
3.   Fix the mounting bracket to the mounting surface with appropriate 

screws and wall plugs, sufficient to take the weight of the fitting. 

4.   Replace the main body of the floodlight to the bracket, ensuring 

that cables are not trapped between the base mounting bracket 

and the floodlight,

MOUNTING 

BRACkET

MOUNTING BRACkET 

RETAINING/ADJUSTMENT BOLTS

5.   Connect the floodlight to the mains supply, with an appropriate 

junction box or connection fitting, making sure any exposed 

connections and joints are sufficiently weatherproofed. When 

using with 110V supply make sure the correct CEE plug is fitted to 

connect to the transformer.

6.  Then make the electrical connections as follows:

 

LIVE

 - (Red or Brown) to a terminal marked 

L

 

NEUTRAL

 - (Black or Blue) to a terminal marked 

N

 

EARTH

 - (Green/Yellow) to a terminal marked  

 

WARNING - THIS FITTING MUST BE EARTHED

7.   Ensure that there are no exposed conductors, loose or trapped 

cable strands.

8.   Adjust the angle of the floodlight by the retaining/adjustment bolt, 

making sure the bolt is retightened.

9.   Switch on the power supply to test.

MAINTENANCE

1.   Please make sure the power is switched off before starting any 

maintenance. 

2.   In order to maintain good even light coverage, the protective front 

cover should be cleaned regularly. 

3.  For good heat dissipation the floodlight housing should also be 

cleaned regularly.

4.  Please take care when cleaning the protective front cover or 

floodlight housing. 

 

DO NOT USE water or cleaning solutions, cleaning should preferably 

be done with a clean dry cloth.   