background image

HGEN Series

Refrigerated Type Compressed Air Dryers
Models:  HGEN600, HGEN800, HGEN1000, HGEN1200

F OR M N O.: 7426448    R EVI S I ON: 10/2018

R EAD AN D U N D E R STAN D TH I S MAN UAL PR I OR TO OPE RATI N G OR S E RVI CI N G TH I S PR OD U CT.

I N STR U CTI ON MAN UAL

MCGUIRE AIR COMPRESSORS INC

1-888-229-9999

MCGUIRE AIR COMPRESSORS INC

1-888-229-9999

Содержание HGEN Series

Страница 1: ...GEN800 HGEN1000 HGEN1200 FOR M NO 7426448 R EVI S ION 10 2018 R EAD AN D U N D E R STAN D TH I S MAN UAL PR IOR TO OPE RATI NG OR S E RVICI NG TH I S PROD UCT I N STR UCTION MAN UAL MCGUIRE AIR COMPRE...

Страница 2: ...HGEN600A 11 Models HGEN800A through HGEN1200A 12 Air and Refrigerant Flow Schematics Model HGEN600A 13 Models HGEN800A through HGEN1200A 14 WATER COOLED UNITS General Arrangement Drawings Model HGEN60...

Страница 3: ...ators are attached to the shipping container before it leaves the factory Check these before accepting unit from carrier s agent Check for Visible Loss or Damage If this shipment shows evidence of los...

Страница 4: ...perating pressure given on the dryer data plate and must be in accordance with applicable codes Support all piping do not allow the weight of any piping to stress the dryer or filter con nections Pipi...

Страница 5: ...f Time using step 2 4 To store the Off Time press the Enter button 5 again 5 Exiting the Program will cause the Timer Drain to discharge and begin a new cycle NOTE Failure to perform step 3 within 10...

Страница 6: ...r connection and support of compressed air lines to the dryer check bypass valve system if installed 4 Energize Dryer Turn disconnect switch to ON position Green dryer ON OFF switch will illuminate En...

Страница 7: ...body may need to be cleaned under condi tions of gross particulate contamination To disassemble the drain valve body for cleaning and other maintenance 1 Turn power switch off 2 Disconnect main power...

Страница 8: ...ure too high Verify ambient temperature throughout day High pressure switch activated Press manual reset button to switch to reset button Compressor overheated Turn dryer off Contact local distributor...

Страница 9: ...igh a c 398 psig manual reset 27 4 barg manual reset High w c 313 psig manual reset 21 6 barg manual reset Air Cooled Condensers Air Flow Across Condenser cfm 60 Hz 2 825 4 120 4 120 4 120 Condenser F...

Страница 10: ...44 1281 3 4 86 123 5 7 94 201 6 3 23 82 0 26 74 679 2 20 24 514 4 18 106 2 40 94 1040 49 26 1251 2 2 NPT 344 156 DRIED AIR OUTLET WETTED AIR INLET AIR FLOW COOLING HOLE FOR MAIN POWER DRAIN OUTLET 5 1...

Страница 11: ...536 10 00 254 26 77 680 28 35 720 37 40 950 41 34 1050 59 83 1519 6 35 22 894 5 6 12 155 5 3 35 85 3 ANSI Flange 695 315 WETTED AIR INLET DRIED AIR OUTLET COOLING AIR FLOW REAR VIEW FRONT VIEW LEFT S...

Страница 12: ...629 6 38 68 982 5 6 59 167 5 3 35 85 4 ANSI Flange 744 337 HGEN1200A 31 60 802 7 20 60 523 3 11 00 279 4 26 77 680 28 35 720 41 34 1050 45 28 1150 64 16 1629 6 38 68 982 5 6 59 167 5 3 35 85 4 ANSI Fl...

Страница 13: ...TH Thermal Relay S3 Fan pressure switch S1 Switch on off S4 High pressure switch SENSOR Temperature Sensor GL1 Green Lamp SOL1 Electronic drain DCB Digtal Control Board 120V 0V 50VA 480V 0V TRANSFORME...

Страница 14: ...P1 CIRCUIT PROTECTOR FOR CONTROL POWER S1 SWITCH ON OFF MC2 MAGNETIC CONTACTOR FOR MOTOR S2 FAN PRESSURE SWITCH SENSOR TEMPERATURE SENSOR GL1 GREEN LAMP SOL1 ELECTRONIC DRAINVALVE 1 DCB2 DIGITAL CONTR...

Страница 15: ...DISPLAY TI SCHRADERVALVE REF AIR S WETTED AIR INLET DRIED AIR OUTLET AIR AIR MOISTURE SEPARATOR INTEGRATED BRAZED PLATE HEAT EXCHANGER STRAINER BALLVALVE DRAIN OUTLET TIMED ELECTRIC AUTO DRAINVALVE F...

Страница 16: ...ESSED AIR FLOW REFRIGERANT FLOW WETTED COMPRESSED AIR INLET DRYED COMPRESSED AIR OUTLET MOISTURE SEPARATOR INTEGRATED BRAZED PLATE HEAT EXCHANGER 1 S MOISTURE SEPARATOR INTEGRATED BRAZED PLATE HEAT EX...

Страница 17: ...4 86 123 5 7 94 201 6 3 23 82 26 74 679 2 20 24 514 4 18 106 2 40 94 1040 49 26 1251 2 4 52 114 8 9 84 250 1 97 50 2 NPT 3 4 NPT 358 162 DRIED AIR OUTLET WETTED AIR INLET COOLING WATER OUTLET COOLING...

Страница 18: ...36 10 00 254 26 77 680 28 35 720 37 40 950 41 34 1050 41 34 1050 35 22 894 5 6 12 155 5 3 35 85 6 40 162 5 9 84 250 1 97 50 3 ANSI Flange 3 4 NPT 534 242 AIR INLET AIR OUTLET COOLING WATER OUTLET COOL...

Страница 19: ...5 3 35 85 6 40 162 5 9 84 250 1 97 50 4 ANSI Flange 1 NPT 582 264 HGEN1200W 31 60 802 7 20 60 523 3 11 00 279 4 26 77 680 28 35 720 41 34 1050 45 28 1150 41 34 1050 38 68 982 5 6 59 167 5 3 35 85 6 4...

Страница 20: ...lay S1 Switch on off S2 High pressure switch SENSOR Temperature Sensor GL1 Green Lamp SOL1 Electronic drain DCB Digtal Control Board 120V 0V 50VA 480V 0V TRANSFORMER 460V 3PH 60Hz L2 F1 2A TH MC1 U1 V...

Страница 21: ...TH1 MANUAL MOTOR STARTER FOR REF COMP CP1 CIRCUIT PROTECTOR FOR CONTROL POWER S1 SWITCH ON OFF S2 HIGH PRESSURE SWITCH SENSOR TEMPERATURE SENSOR GL1 GREEN LAMP SOL1 ELECTRONIC DRAINVALVE 1 DCB2 DIGIT...

Страница 22: ...IGH PRESSURE SWITCH COMPRESSED AIR FLOW REFRIGERANT FLOW WETTED COMPRESSED AIR INLET DRYED COMPRESSED AIR OUTLET MOISTURE SEPARATOR INTEGRATED BRAZED PLATE HEAT EXCHANGER EXPANSIONVALVE CAPILLARY TUBE...

Страница 23: ...AIR FLOW REFRIGERANT FLOW WETTED COMPRESSED AIR INLET DRYED COMPRESSED AIR OUTLET MOISTURE SEPARATOR INTEGRATED BRAZED PLATE HEAT EXCHANGER 1 S MOISTURE SEPARATOR INTEGRATED BRAZED PLATE HEAT EXCHANG...

Страница 24: ...439991 1 14 Contactor Compressor 3242864 7439992 7439992 7439992 1 15 Contactor Fan Motor 3242863 7439993 7439993 7439993 1 16 Surpressor Spark Killer 7439994 7439994 7439994 7439994 1 17 Circuit Prot...

Страница 25: ...23 NOTES MCGUIRE AIR COMPRESSORS INC 1 888 229 9999 MCGUIRE AIR COMPRESSORS INC 1 888 229 9999...

Страница 26: ...24 NOTES MCGUIRE AIR COMPRESSORS INC 1 888 229 9999 MCGUIRE AIR COMPRESSORS INC 1 888 229 9999...

Страница 27: ...or the unexpired portion of the warranty applying to the original product The foregoing is the exclusive remedy of any buyer of the manufacturer s product The maximum damages liability of the manufact...

Страница 28: ...Improvements and research are continuous at SPX FLOW Inc Specifications may change without notice ISSUED 10 2018 Form No 7426448 Revision B COPYRIGHT 2018 SPX FLOW Inc HGEN Series Refrigerated Type Co...

Отзывы: