Never put your fingers into the pump’s suction or pressure side with the pump
connected to mains electricity.
-
When using flexible hoses make sure that they are suitable for the pumps
performance and do not leach out dangerous substances into the water.
-
When using non return valves ensure proper function, otherwise there is great
danger of the pumps running dry.
-
If required, use a strainer with app 2-3 mm opening on the suction side. When
using finer filtration (sponges etc) make sure that they are always cleaned at
short intervals, to prevent cavitations and possible damage to the pump.
-
Do not operate the pump with a shut off valve on the suction side, partly or
fully closed.
Installation of the controller
Install the controller in a dry, suitably vented place, away from water, dampness
and other heat sources like sunlight, artificial light etc. For optimum cooling effect of
the controller housing, it is best to mount it vertically. Use the holes in the
controller’s bracket. Never cover the controller. Resulting overheating could damage
the controller
Starting the pump
Check that the power supply is suitable for the pump. Refer to the pumps label.
Use the pump with an electric circuit breaker.
Overload protection
E-
Flow
pumps are protected against overloading. If the impeller is blocked the
pump is switched off automatically. If the cause of the blockage is removed the
pump can be restarted or will start on its own.
Power cut new start
After a power cut or the pump having being switched off, the pump will assume its
old setting when the power comes back on.
-9-
Содержание E-Flow 10
Страница 22: ...E FLOW Deltec E Flow up down E Flow Deltec E Box 30 Deltec E Flow 16 Deltec GmbH 22...
Страница 23: ...2 32 40 300 2 3 30 0 0 UP 20 down 0 down 23...
Страница 24: ...9 Remote 2012 10 11 e f F 12 UP DOWN 24...
Страница 26: ......
Страница 27: ...27...
Страница 28: ...28 Deltec E BOX Die E Box ist ein multifunktionales E Flow Pumpen Steuerger t...
Страница 31: ......