![Deltaplus TC007 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/deltaplus/tc007/tc007_manual_2479140003.webp)
EN 341:2011 Class A
WORKING LOAD:
m
inimum rated load is
3
0
kg,
maximum rated load is 1
8
0
kg.
M
AXIMUM DESCENT DISTANCE:
190
m (in this case approved for
22
consecutive descents)
A
PPROVED TEMPERATURE RANGE:
-20 °C
≤
approved temperature
≤
+60 °C
ROPE TYPE(S):
T
ests according to the norm EN 341:2011 have been
performed with the following low stretch kernmantel ropes
(concordant with EN 1891).
TESTED AND APPROVED FOR DESCENTS WITH A
RELEASED ENERGY OF 7,5MJ (according to EN 341
class A).
W = m x g x h x n
m: mass (kg)
2
g: acceleration of gravity = 9,81 m/s
h: height (m)
n: number of descents
SINGING ROCK
Static R44 11.0
11,2 mm
0,1 %
3,2 %
77 g/m
38 %
62 %
3,7 %
PA
Rope model
diameter
sheath slippage
Ss
elongation
E
mass per metre
M
sheath proportion
Sp
core proportion
C
shrinkage
R
material
EN 12841:2006 type C
Certified for use with low stretch (EN 1891 Type A) ropes with
diameters between 10 mm and 12 mm.
225 kg