Deltafan 355/R/6-6/30/400/Ex Скачать руководство пользователя страница 9

 

INSTRUCTION MANUAL 

for „DELTAFAN” wall fans of the type: ***/R/*-*/**/***/Ex 

Page 9/14 

 

 

During operation special attention should be paid to the following: 

 

The access of cooling air from the motor housing cannot be hindered. The housing may have worse 
conducting properties due to the sticking of dust and dirt particles to the fan surface. Therefore, 
the housing surface should be periodically cleaned with a cotton cloth. 

 

During  the  operation  special  attention  should  be  paid  to  motor  operation  and  immediately 
disconnect the motor from the supply network in case of: 

 

excessive motor vibrations, 

 

considerable decrease of rotational speed, 

 

excessive heating up of the motor or bearings. 

 

4.6 THE POWER SUPPLY OF THE FAN MOTOR 

The  „DELTAFAN”  wall  fans  of  the  type  ***/R/*-*/**/***/Ex  are  equipped  with  asynchronous  motors  in  the 
explosion-proof version with certificates of EC type examinations (ATEX). In order to connect the device to the 
electric installation, power supply cables or wires should be lead out through proper cable outlets of the motor 
terminal box. 

Power supply cables should be connected according to given diagrams and observing the following conditions: 

 

The  motors  are  designed  for  the  basic  voltage  of  230/400V  and  can  be  connected  to  the  network  of  the 
inter-lead voltage of 3x400V ±5% with the star motor winding connection (Y) or to the network of the inter-
lead voltage of 3x230V ±5% with delta motor winding connection (Δ). 

 

The installation must have correctly selected overload and short-cut protection. 

 

The installation must have efficient protection against electric shocks. 

 

Leads of the electric installation are to be lead through isolation bushings in the motor terminal box. 

 

Authorised personnel should check whether lead dimensions are appropriate to the maximum consumption 
of the electric power, but their cross-section should not be less than 1mm

2

 

The device should always be earthed. The fan operation without connected PE leads is forbidden. Protection 
leads PE (should of colour yellow-green) should be connected to the terminal marked with the symbol. 

 

Always make sure that the earthing lead is longer than the power supply lead so that it is the last lead in case 
of accidental disconnection (tear out). 

 

Before  starting  up  the  device,  check  the  connections  for  correctness  and  consistency  with  the  enclosed 
electric diagram. Switching on the power supply without previous checking the connections is forbidden. 

 

The  explosion-proof  motors  of  a  standard  reinforced  construction  do  not  have  a  thermal  protection. 
However,  the  motors  can  be  additionally  protected  against  overheating  by  means  of  three  thermistors 
(one for each phase) P-(TC)120-B connected in series, whose leads-out should be connected to an external 
protection circuit or to an electronic resistance relay. When the set temperature is exceeded, the circuit 
should  disconnect  the  device  from  the  power  supply  network.  It  is  recommended  that  the  protection 
circuit accounted for the temperature growth caused by multiple fan motor start-ups. 

Содержание 355/R/6-6/30/400/Ex

Страница 1: ...ca 234B 34 114 Brze nica Phone 48 33 879 20 38 Fax 48 33 879 22 65 E mail biuro deltafan pl INSTRUCTION MANUAL for DELTAFAN wall fans R Ex type The instruction manual should be read before starting up...

Страница 2: ..._____8 4 5 OPERATION ___________________________________________________________________________8 4 6 POWER SUPPLY OF FAN MOTOR ______________________________________________________________9 5 TRANSP...

Страница 3: ...equences which the manufacture cannot be held responsible for The device requires the use of original parts only Damages caused by using incorrect unoriginal materials and other accessories are not su...

Страница 4: ...few rotors equipped with blades uses the energy to constantly transfer a medium Therewith the value of transferred work per a mass unit does not exceed the normal value of 25 kJ kg Wall fans of the ty...

Страница 5: ...powder epoxy polyester paint ALESTA EP KP E45 of the surface resistance of 2x105 106 The fan rotor is made of antistatic polyamide PAGAS die cast and reinforced with glass fibre blades and silumin al...

Страница 6: ...nd are available on our regularly updated website at www deltafan pl The selection of a fan for a particular application should be carried out by a competent person so that the fan operation point in...

Страница 7: ...oncerns the power on the electric motor shaft The current value is given for the star motor connection The level of acoustic pressure in the distance of 1m from the fan with spherical form of sound pr...

Страница 8: ...eeding 5 of the motor rated voltage All rating is related to rated voltage If voltage variations exceed 5 of the rated voltage the motor should not be started The fan motor has protection rating of IP...

Страница 9: ...nnection The installation must have correctly selected overload and short cut protection The installation must have efficient protection against electric shocks Leads of the electric installation are...

Страница 10: ...pecial attention should be paid to stability and inertia of the fan in its packaging Fans and their parts should not be stored in a room with chemical substances causing metal corrosion Fans should be...

Страница 11: ...a wooden hammer o removal of the rotor with bearings o removal of bearing from the motor shaft using three arm pullers only when it is necessary to replace them Bearings should be absolutely replaced...

Страница 12: ...cking the electrical isolation strength high voltage tests should be performed by a trained and qualified person 7 DISPOSAL In the countries of the European Union and other European countries there ar...

Страница 13: ...INSTRUCTION MANUAL for DELTAFAN wall fans of the type R Ex Page 13 14 10 RATING PLATE...

Страница 14: ...irements of the following harmonized standards PN EN 60079 0 2009 PN EN 60079 7 2010 PN EN 13463 2010 PN EN 13463 5 2005 PN EN 14986 2009 PN EN ISO 12100 1 2005 PN EN ISO 12100 2 2005 A1 2009 In the p...