INSTRUCTION MANUAL 

for „DELTAFAN” wall fans of the type: ***/R/*-*/**/***/Ex 

Page 10/14 

 

 

Fig. 2  The connection diagram for the wall fans powered by the three-phase inter-lead current 3x400V 50Hz (star) 

and 3x230V 50Hz (delta). 

Delta connection   

 

 

 

 

 

 

 

Star connection 

 

 

5.   TRANSPORT AND HANDLING 

 

Transport and handling must be performed with great caution to prevent the device from damaging. 

 

Fans  should  be  transported  on  covered  means  of  transportation,  in  wooden  boxes,  on  metal  pallets  or 
carton packages protecting against water and moisture. 

 

The packaging should maintain fans in new, factory condition during storage and transportation, and ensure 
the correct operation of the fan, when it is delivered to the installation location. 

 

When packing, special attention should be paid to stability and inertia of the fan in its packaging. 

 

Fans and their parts should not be stored in a room with chemical substances causing metal corrosion. 

 

Fans should be stored in dry and permeable to air containers, free from gases, fluids and caustic vapours, 
which are harmful to motor isolation and other fan parts. 

 

Fans  cannot  be  stored  in  rooms,  where  chemical  fertilizers,  chlorinated  limes,  acids,  chemical  substances, 
etc. are stored. 

 

The  ambient  temperature  in  the  room,  where  fans  are  stored,  cannot  be  lower  than  278K  (+5°C),  and 
relative humidity cannot exceed 70%. 

 

6.   INSPECTIONS AND MAINTENANCE 

Each working fan should be subjected to periodical inspections: 

 

small inspection – every 12 months, 

 

main inspection: 

o

 

motors of the rotational speed of n = 1500 rpm - 

-  after 6000 working hours 

o

 

motors of the rotational speed of n = 1000 rpm - 

-  after 7000 working hours, but no seldom than every 3 years. 

 

Содержание 355/R/6-6/30/400/Ex

Страница 1: ...ca 234B 34 114 Brze nica Phone 48 33 879 20 38 Fax 48 33 879 22 65 E mail biuro deltafan pl INSTRUCTION MANUAL for DELTAFAN wall fans R Ex type The instruction manual should be read before starting up...

Страница 2: ..._____8 4 5 OPERATION ___________________________________________________________________________8 4 6 POWER SUPPLY OF FAN MOTOR ______________________________________________________________9 5 TRANSP...

Страница 3: ...equences which the manufacture cannot be held responsible for The device requires the use of original parts only Damages caused by using incorrect unoriginal materials and other accessories are not su...

Страница 4: ...few rotors equipped with blades uses the energy to constantly transfer a medium Therewith the value of transferred work per a mass unit does not exceed the normal value of 25 kJ kg Wall fans of the ty...

Страница 5: ...powder epoxy polyester paint ALESTA EP KP E45 of the surface resistance of 2x105 106 The fan rotor is made of antistatic polyamide PAGAS die cast and reinforced with glass fibre blades and silumin al...

Страница 6: ...nd are available on our regularly updated website at www deltafan pl The selection of a fan for a particular application should be carried out by a competent person so that the fan operation point in...

Страница 7: ...oncerns the power on the electric motor shaft The current value is given for the star motor connection The level of acoustic pressure in the distance of 1m from the fan with spherical form of sound pr...

Страница 8: ...eeding 5 of the motor rated voltage All rating is related to rated voltage If voltage variations exceed 5 of the rated voltage the motor should not be started The fan motor has protection rating of IP...

Страница 9: ...nnection The installation must have correctly selected overload and short cut protection The installation must have efficient protection against electric shocks Leads of the electric installation are...

Страница 10: ...pecial attention should be paid to stability and inertia of the fan in its packaging Fans and their parts should not be stored in a room with chemical substances causing metal corrosion Fans should be...

Страница 11: ...a wooden hammer o removal of the rotor with bearings o removal of bearing from the motor shaft using three arm pullers only when it is necessary to replace them Bearings should be absolutely replaced...

Страница 12: ...cking the electrical isolation strength high voltage tests should be performed by a trained and qualified person 7 DISPOSAL In the countries of the European Union and other European countries there ar...

Страница 13: ...INSTRUCTION MANUAL for DELTAFAN wall fans of the type R Ex Page 13 14 10 RATING PLATE...

Страница 14: ...irements of the following harmonized standards PN EN 60079 0 2009 PN EN 60079 7 2010 PN EN 13463 2010 PN EN 13463 5 2005 PN EN 14986 2009 PN EN ISO 12100 1 2005 PN EN ISO 12100 2 2005 A1 2009 In the p...

Отзывы: