VIVOTEK
318 - User's Manual
© 2019 VIVOTEK INC. All Right Reserved
184
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
* When "exposure_mode"=0, this
value must be set to "-".
* Only available when
"capability_image_c<0~(n-1)>_
exposure_mode" is 1.
exposure_winmode
auto,
custom,
blc,
hlc,
center,
-
<product
dependent>
0/7
Available options for
"exposurewin_c<0~(n-1)>_mode"
* "-" means group: exposurewin is not
supported.
* When exposure_mode="0", this
value must be set to "-".
* Only available when
"capability_image_c<0~(n-1)>_
exposure_mode" is 1.
exposure_meteringm
ode
auto,
blc,
hlc
<product
dependent>
0/7
Available options for
"videoin_c<0~(n-1)>_meteringmode"
* Only available when
"capability_image_c<0~(n-1)>_
exposure_mode" is 1.
exposure_hlcmode_s
upportwindow
<boolean>
0/7
Indicate whether to support exposure
window in hlc mode.
* Only available when
"capability_image_c<0~(n-1)>_
exposure_mode" is 1 and hlc is listed
in "capability_image_c<0~(n-1)>_
exposure_winmode".
exposure_hlcmode_af
fect
-,
sir:hidden:
or others
<x>: nonnegative
integer
<product
dependent>
0/7
When hlc mode is enabled, some
features may become malfunction or
be forced to a given value. The
affected functions are list here.
The format is "Affect API
name":"Policy":"Description"
"Policy" can be categorized into
following groups:
- (disabled) : UI turns grey and users
can't select it.