VENTILATION FAN / LED LIGHT

MODELS 80HLED / 80LED / 80LED-ADJ / 100HLED / 100LED

Installation and Operating Instructions

READ AND SAVE THESE INSTRUCTIONS

GENERAL SAFETY INFORMATION

1.  Make sure that the electric service supply voltage 

is AC 120V, 60Hz.

2.  Follow all local electrical and safety codes, as well 

as the National Electrical Code (NEC) and the 

Occupational Safety and Health Act (OSH Act).

3.  Always disconnect the power source before 

working on or near the ventilating fan, motor or 

junction box.

4.  Protect the power cord from sharp edges, oil, 

grease, hot surfaces, chemicals or other objects.

5.  Do not kink the power cord.
6.  Do not install the unit where ducts are confugured 

as shown in Fig.A.

7.  Provide suction parts with proper ventilation.
8.  This unit is UL Listed for use over a bathtub or 

shower when installed in a GFCI protected branch 

circuit.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC 
SHOCK, OR INJURY TO PERSONS, OBSERVE THE 
FOLLOWING:

1.  Use this unit only in the manner intended by the 

manufacturer. If you have questions, contact the 

manufacturer.

2.  Before servicing or cleaning the unit, switch the 

disconnecting means to prevent the power from 

being switched on accidentally. When the service 

disconnecting means cannot be locked, securely 

fasten a prominent warning device, such as a tag, 

to the service panel.

3.  Installation work and electrical wiring must be 

rated construction.

4. 

fuel burning equipment to prevent backdrafting. 

Follow the heating equipment manufacturer’s 

guideline and safety standards such as those 

published by the National Fire Protection 

Association (NFPA), and the American Society 

for Heating Refrigeration and Air Conditioning 

Engineers (ASHRAE) and local code authorities.

5.  When cutting or drilling into the wall or ceiling, 

do not damage electrical wiring and other hidden 

utilities.

6.  Ducted ventilating fans must always be vented to 

the outdoors.

7.  If this unit is to be installed over a tub or shower, it 

must be marked as appropriate for the application 

and be connected to a GFCI (Ground Fault Circuit 

lnterrupter) – protected branch circuit.

8.  Do not use this unit with any other solid-state 

control device. Solid-state controls may cause 

harmonic distortion, which can cause a motor 

humming noise.

9.  NEVER place a switch where it can be reached 

from a tub or shower.

10. Not to be installed in a ceiling thermally insulated 

to a value greater than R40. (This is required for 

installation in Canada only).

11. Do not open/disassemble LED light engine.

 

Fig. A

Turning angle too large

Too many elbows

Duct shrink

Elbow near the body

.

Body

Minimum 18 in.

CAUTION

1.  For general ventilating use only. Do not use to 

exhaust hazardous or explosive materials and 

vapors.

2.  Not for use in cooking areas. (Fig.B)
3.  This product must properly connect to the 

grounding conductor of the supply circuit.

4.  To reduce the risk of injury to persons, install the 

Cooking area

Do not install above or

inside this area

Cooking

Equipment

Fig. B

45

°

45

°

PREPARATION

Tools Required for Assembly (not included): Hammer, 

Flathead Screwdriver, Wire Nuts, Nails, Duct Tape, 

Phillips Head Screwdriver, Utility Knife  

Helpful Tools (not included): Electric Drill, Drill Bits

before beginning installation.

  Carefully remove unit from carton.

  Check area above installation location to be sure 

that wiring can run to the planned location and 

that duct work can be run. Make sure the area is 

  Inspect duct work and wiring before proceeding with 

installation.

  Before installation, provide inspection and future 

maintenance access at a location that will not 

interfere with installation work.

  You may need the help of a second person to install 

this fan: one person on the attic side and one on the 

room side.

Note: Installations may vary depending on how the 

previous bath fan was installed. Supplies necessary for 

the installation of your bath fan are not all included. 

However, most are available at your local home 

improvement or hardware store.

Roof cap

(with built-in

damper)

Seal gap

around 

housing

Caulk termination

to duct

Fan housing

Short piece of flexible

duct helps alignment

and absorbs sound

or

Wall cap

(with built-in

damper)

Wall cap

(with built-in

damper)

2~3 ft straight run 

before elbow

MFG MODELS VFB80HLED2 / VFB080C4LED2 / VFB080C4LED2-A / VFB100HLED2 / VFB100C4LED1

Locate unit away from heating or cooling sources

which can affect humidity levels.

 

Do not locate near window. Unit may respond to the

outdoor humidity level.

 

Unit must be installed in ceiling to properly sense

moisture.

 

Locate unit only on flat ceilings up to 12 feet high for

proper sensing.

Proper insulation around the fan to minimize building

heat loss and gain. The ducting from this fan to the

outside of the building has a strong effect on the air

flow, noise and energy use of the fan.

 

Use the shortest, straightest duct routing possible for 

best performance, and avoid installing the fan with 

smaller ducts than recommended. Insulation around 

the ducts can reduce energy loss and inhibit mold 

growth.

 

Fans installed with existing ducts may not achieve

their rated air flow.

Humidity sensing models :

The fan will operate most efficiently when located

where the shortest possible duct run and minimum 

number of elbows will be needed.

 

Locate unit above (GFCI-protected circuit required)

or within 5 feet of the shower head.

 

Use a roof cap or wall cap that has a built-in damper 

to reduce backdrafts.

 

External timer can be used in conjunction with 

singlespeed mode only, please contact Delta Breez 

customer service and consult with a licensed 

electrician for compatibility.

 

External dimmer can be used in conjunction with LED

light model, please contact Delta Breez customer

service and consult with a licensed electrician for

compatibility. 

Содержание VFB080C4LED2-A

Страница 1: ...ust properly connect to the grounding conductor of the supply circuit 4 To reduce the risk of injury to persons install the Cooking area Do not install above or inside this area Cooking Equipment Fig B 45 45 PREPARATION Tools Required for Assembly not included Hammer Flathead Screwdriver Wire Nuts Nails Duct Tape Phillips Head Screwdriver Utility Knife Helpful Tools not included Electric Drill Dri...

Страница 2: ...utside Gradient 1º 2º EXISTING CONSTRUCTION ACCESSIBLE FROM BELOW No Attic Access 1 Measure the existing ceiling opening or cut a new opening to ensure it is large enough to accommodate the new fan 9 in x 9 in suggested A piece of wood not provided may be necessary that is screwed in from below through the ceiling board Suggested size is H 4 in x L 14 in Position the screws far enough from the edg...

Страница 3: ... to operate ON CARE AND MAINTENANCE See safety information before proceeding Routine maintenance should be done at least once a year Never use solvents thinner or harsh chemicals when cleaning the fan Do not allow water to enter the motor Do not immerse metal parts in water Do not immerse resin parts in water over 140º Fahrenheit 1 To remove grille unplug the light connector squeeze springs and pu...

Страница 4: ...tive product will be supplied free of charge for installation by the consumer The warranty provided herein does not cover charges for labor or other costs incurred in the troubleshooting repair removal and installation service 2 All returns of defective parts or products must include the product model number and must be made through an authorized Delta Electronics distributor Authorized returns mu...

Отзывы: