A separate electrical circuit should be used for your machines. This circuit should not be less than #12 wire and should
be protected with a 20 Amp time lag fuse. If an extension cord is used, use only 3-wire extension cords which have 3-
prong grounding type plugs and matching receptacle which will accept the machine’s plug. Before connecting the
machine to the power line, make sure the switch (s) is in the “OFF” position and be sure that the electric current is of
the same characteristics as indicated on the machine. All line connections should make good contact. Running on low
voltage will damage the machine.

DO NOT EXPOSE THE MACHINE TO RAIN OR OPERATE THE MACHINE IN DAMP LOCATIONS.

Fig. A

Fig. B

GROUNDED OUTLET BOX

CURRENT

CARRYING

PRONGS

GROUNDING BLADE
IS LONGEST OF THE 3 BLADES

GROUNDED OUTLET BOX

GROUNDING

MEANS

ADAPTER

2. Grounded, cord-connected machines intended for
use on a supply circuit having a nominal rating less
than 150 volts:

If the machine is intended for use on a circuit that has an
outlet that looks like the one illustrated in Fig. A

,

the

machine will have a grounding plug that looks like the plug
illustrated in Fig. A

.

A temporary adapter, which looks like

the adapter illustrated in Fig. B, may be used to connect
this plug to a matching 2-conductor receptacle as shown
in Fig. B if a properly grounded outlet is not available. The
temporary adapter should be used only until a properly
grounded outlet can be installed by a qualified electrician.
The green-colored rigid ear, lug, and the like, extending
from the adapter must be connected to a permanent
ground such as a properly grounded outlet box. Whenever
the adapter is used, it must be held in place with a metal
screw.

NOTE: In Canada, the use of a temporary adapter is not
permitted by the Canadian Electric Code.

IN ALL CASES, MAKE CERTAIN THE

R E C E P TA C L E I N Q U E S T I O N I S P R O P E R LY
G R O U N D E D . I F Y O U A R E N O T S U R E H AV E A
QUALIFIED ELECTRICIAN CHECK THE RECEPTACLE.

1. All grounded, cord-connected machines: 

In the event of a malfunction or breakdown, grounding
provides a path of least resistance for electric current to
reduce the risk of electric shock. This machine is
equipped with an electric cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into a matching outlet that is properly installed
and grounded in accordance with all local codes and
ordinances.

Do not modify the plug provided - if it will not fit the outlet,
have the proper outlet installed by a qualified electrician.

Improper connection of the equipment-grounding
conductor can result in risk of electric shock. The
conductor with insulation having an outer surface that is
green with or without yellow stripes is the equipment-
grounding conductor. If repair or replacement of the
electric cord or plug is necessary, do not connect the
equipment-grounding conductor to a live terminal.

Check with a qualified electrician or service personnel if
t h e g r o u n d i n g i n s t r u c t i o n s a r e n o t c o m p l e t e l y
understood, or if in doubt as to whether the machine is
properly grounded.

Use only 3-wire extension cords that have 3-prong
grounding type plugs and matching 3-conductor
receptacles that accept the machine’s plug, as shown in
Fig. A.

Repair or replace damaged or worn cord immediately.

POWER CONNECTIONS

MOTOR SPECIFICATIONS

Your machine is wired for 120 volts, 60 HZ alternating current. Before connecting the machine to the power source,
make sure the switch is in the “OFF” position. 

GROUNDING INSTRUCTIONS

THIS MACHINE MUST BE GROUNDED WHILE IN USE TO PROTECT THE OPERATOR FROM
ELECTRIC SHOCK.

Содержание ShopMaster JT160

Страница 1: ...ite at www deltamachinery com For Parts Service Warranty or other Assistance please call 1 800 223 7278 In Canada call 1 800 463 3582 6 Variable Speed Bench Jointer Model JT160 PART NO A05756 09 09 04...

Страница 2: ...deltamachinery com Postal Mail Technical Service Manager Delta Machinery 4825 Highway 45 North Jackson TN 38305 Information regarding the safe and proper operation of this tool is available from the f...

Страница 3: ...EMS The symbols below are used to help you recognize this information SAFETY GUIDELINES DEFINITIONS SOME DUST CREATED BY POWER SANDING SAWING GRINDING DRILLING AND OTHER CONSTRUCTION ACTIVITIES contai...

Страница 4: ...a machine or an attachment to do a job for which it was not designed Damage to the machine and or injury may result 13 USE RECOMMENDED ACCESSORIES The use of accessories and attachments not recommend...

Страница 5: ...piece can cause kickback and result in serious injury 15 NEVER PERFORM FREE HAND OPERATIONS Use the fence to position and guide the workpiece Loss of control of the workpiece can cause serious injury...

Страница 6: ...with a metal screw NOTE In Canada the use of a temporary adapter is not permitted by the Canadian Electric Code IN ALL CASES MAKE CERTAIN THE RECEPTACLE IN QUESTION IS PROPERLY GROUNDED IF YOU ARE NO...

Страница 7: ...20 50 100 16 AWG 0 6 120 100 150 14 AWG 6 10 120 up to 25 18 AWG 6 10 120 25 50 16 AWG 6 10 120 50 100 14 AWG 6 10 120 100 150 12 AWG 10 12 120 up to 25 16 AWG 10 12 120 25 50 16 AWG 10 12 120 50 100...

Страница 8: ...Nut 12 M6x1 Square Nut 2 13 7 64 Hex Wrench 14 Cutterhead Lock UNPACKING AND CLEANING Carefully unpack the machine and all loose items from the shipping container s Remove the protective coating from...

Страница 9: ...AND YOU READ AND UNDERSTAND THE ENTIRE INSTRUCTION MANUAL Fig 5 Fig 6 Fig 7 Fig 8 FENCE 1 Assemble the fence mounting bracket A Fig 5 to the jointer base using the four M6x1x16mm button head screws B...

Страница 10: ...e L Fig 10 over square nuts J 5 Position fence L Fig 11 so that rounded section M on bottom of fence is over cutterhead opening 6 Tighten two screws G Fig 12 using included hex wrench H J G J L L M G...

Страница 11: ...FIG 15 ONLY WHEN SETTING KNIVES ALL OTHER TIMES THE CUTTERHEAD LOCK A SHOULD BE DISENGAGED FROM THE CUTTERHEAD FIG 16 A B A FASTENING JOINTER TO SUPPORTING SURFACE If during operation there is any ten...

Страница 12: ...cated on the front of the jointer To turn the machine ON move switch A up to the ON position 2 To turn the machine OFF move the switch down to the OFF position MAKE SURE THAT THE SWITCH IS IN THE OFF...

Страница 13: ...sen lock lever A Fig 25 slide the fence to the desired position on the table and tighten lever A NOTE Lock lever A is spring loaded and can be repositioned by pulling up on the lever and repositioning...

Страница 14: ...ver the knife as shown Using wrench C supplied turn screw E until knife just touches straight edge Adjust knife at near end of cutterhead in the same manner turning screw F Tighten four screws A Fig 3...

Страница 15: ...3 Fig 34 KNIVES SET TOO LOW OUT FEED TABLE IN FEED TABLE CUTTER MATERIAL KNIVES SET TOO HIGH IN FEED TABLE OUT FEED TABLE CUTTER GOUGE MATERIAL IN FEED TABLE CUTTER OUT FEED TABLE KNIVES AT CORRECT HE...

Страница 16: ...er Set the guide fence square with the table Depth of cut should be the minimum required to obtain a straight edge Hold the best face of the piece firmly against the fence throughout the feed as shown...

Страница 17: ...WIDER THAN 6 INCHES 152 4 mm OR LESS THAN 1 2 INCH 12 7 mm THICK Fig 40 Fig 41 Fig 42 Fig 43 DIRECTION OF GRAIN Avoid feeding work into the jointer against the grain as shown in Fig 42 The result will...

Страница 18: ...ssed air All plastic parts should be cleaned with a soft damp cloth NEVER use solvents to clean plastic parts They could possibly dissolve or otherwise damage the material Wear ANSI Z87 1 safety glass...

Страница 19: ...uld be hazardous For safest operation only Delta recommended accessories should be used with this product ACCESSORIES PARTS SERVICE OR WARRANTY ASSISTANCE All Delta Machines and accessories are manufa...

Страница 20: ...Delta may require that electric motors be returned prepaid to a motor manufacturer s authorized station for inspection and repair or replacement Delta will not be responsible for any asserted defect...

Страница 21: ...r Cable Delta m s cercano ARIZONA Tempe 85282 Phoenix 2400 West Southern Avenue Suite 105 Phone 602 437 1200 Fax 602 437 2200 CALIFORNIA Ontario 91761 Los Angeles 3949A East Guasti Road Phone 909 390...

Отзывы: