![Delta RTU-ECAT Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/delta/rtu-ecat/rtu-ecat_operation-manual_2471849008.webp)
Chapter 2 Overview
2-3
2_
Environment
Item
Specification
Noise Immunity
ESD
(
IEC 61131-2, IEC 61000-4-2
)
: 8KV Air Discharge, 6KV Contact
Discharge
EFT
(
IEC 61131-2, IEC 61000-4-4
)
: Power Line: 2KV, Digital I/O: 1KV
Communication I/O: 2KV
Damped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KV
RS
(
IEC 61131-2, IEC 61000-4-3
)
: 80MHz ~ 1000MHz, 10V/m; 1400MHz
~ 6000MHz, 3V/m
Operation
0ºC ~ 55ºC (temperature), 50 ~ 95% (humidity), pollution degree 2
Storage
-25ºC ~ 70ºC (temperature), 5 ~ 95% (humidity)
Vibration/shock
resistance
Standard: IEC 61131-2, IEC 68-2-6 (TEST Fc)/IEC 61131-2 & IEC
68-2-27 (TEST Ea)
Safety
Conforms to IEC 61131-2, UL 61010-1, UL 61010-2-201
Barometric
pressure-altitude
Operating: 1080~795hPa (-1000~2000m)
Storage: 1080~660hPa (-1000~3500m)
Weight
84g
2.3
Extension Modules Connectable to RTU-ECAT
RTU-ECAT
PO WER
RU N
AL AR M
R UN
ST O P
N
O
D
E
AD
D
R
ES
S
x 10
x 10
1
0
5
4
3
2
1
0
9
8
7
6
5
4
3
2
1
0
9
8
7
6
Et
he
rC
A
T
IN
O
U
T
Digital modules connectable to RTU-ECAT
DI/DO module
(Model name)
Default I/O mapping data
(EtherCAT master
→
RTU-ECAT)
Default I/O mapping data
(RTU-ECAT
→
EtherCAT master)
DVP08SM11N
N/A
8 bits
DVP08SM10N
N/A
8 bits
DVP16SM11N
N/A
16 bits
Содержание RTU-ECAT