background image

Model

N2E

Data communication method

Wireless communication

Rated voltage

DC3.3V

Power consumption

2 W or lower

Operating temperature range

-20°C to 85°C (no freezing permitted)

Operating humidity range

0% to 90% (no condensation permitted)

Dimensions

167 mm x 80.3 mm (cover and antenna)

77 (mm) (antenna)

Weight

130 grams (including antenna)

5.5.Wireless Communication Unit for Inverter (Wireless Set)

92

The antenna can be detached from the main unit.

63.1mm

124.3mm

74mm

46mm

167mm

77mm

60.1mm

80.3mm

Specifications

Содержание R4E

Страница 1: ...The power behind competitiveness Delta Power Monitor User Manual R4E for energy storage system www deltaww com...

Страница 2: ......

Страница 3: ...Interpreting and Operating Power Monitor Home screen Energy Log Information Setting Inverter Status When Something Seems Wrong Troubleshooting Error Displays Troubleshooting Specifications Power Moni...

Страница 4: ...autions for Your Safety Failing to handle the Product properly may result in the described danger leading to slight or intermediate level injuries and in some cases may also result in serious injury o...

Страница 5: ...es kitchens and the like Do not use organic solvents paint thinners benzene and the like strong alkaline substances or strong acidic substances to clean the case of the Product There is danger of disc...

Страница 6: ...e that is prevented from having air flow such as inside closets or under stairs Install the Product with the DELTA logo facing up when installing the Power Monitor on a wall When not installed on a wa...

Страница 7: ...d the like Keep the power supply breaker for solar power generation of the Meter turned ON at all times when the Product is in use Precautions for Use 7 Reverting the date and time by at least a 15 mi...

Страница 8: ...ar space as possible 13 The Product is not compatible with the Total Amount Purchasing System of the Feed in Tariff Scheme for Reusable Energy 14 Do not pull out the USB Wireless Module while the powe...

Страница 9: ...display on which becomes difficult to view when soiled with fingerprints sweat or oil Wipe dry with a piece of dry soft cloth Do not remove soiling by using excessive force Doing so may result in the...

Страница 10: ...the wireless communication when the Wireless Set is in use The Energy Saving Guide function has been incorporated R4 is specifically used with energy storage solar system User can view the status of t...

Страница 11: ...Wood screws for Wall Surface Desktop Mounting Plate dia 4 x 20 mm AC Adapter Power Meter Shape Qty Remarks This is a plate used to install the Product on a wall or on a desk These are wood screws for...

Страница 12: ...Desktop Mounting Plate dia 4 x 20 mm AC Adapter Power Meter Shape Qty Remarks This is a plate used to install the Product on a wall or on a desk These are wood screws for the Wall Surface Desktop Mou...

Страница 13: ...ication Unit Wireless Set S4E_WiFi 7 8 1 unit 1 pc Wireless Communication Unit Antenna for Inverter Wireless Communication Unit for Inverter This is an antenna that is mounted on the Wireless Communic...

Страница 14: ...the USB Wireless Module provided with the Wireless Set Customers are requested to procure their own USB memory and USB cable Insertion slot for anchoring the Wall Surface Mounting Plate This is the in...

Страница 15: ...Wireless Communication Unit Pressing this button restarts the Wireless Communication Unit Holding this button down for five or more seconds reverts the Wireless Communication Unit to the default sett...

Страница 16: ...t Pressing this button restarts the Wireless Communication Unit Holding this button down for five or more seconds reverts the Wireless Communication Unit to the default setting Caution is required Wir...

Страница 17: ...e Product 17 USB Wireless Module Wireless Set USB insertion slot This is installed on the USB terminal of the Power Monitor Button Not used Operation LED lamp Blue light blinking Standby Blue light on...

Страница 18: ...is the antenna used to perform wireless communication with the Power Monitor The antenna can be detached from the main unit Do not remove the antenna Communication cable insertion slot Not used RS485...

Страница 19: ...and the weight of the main unit Use countersunk screws of 4 dia when installing at a location where the provided wood screws cannot be used Apply torque of 1 5 to 2 0 Nm when installing wood screws on...

Страница 20: ...unting Plate and Part A at the bottom of the main unit as shown in the figure to the right 2 2 Desktop Installation 2 3 Guiding the AC Adapter Cable Remove the tab on the wiring access using a pair of...

Страница 21: ...can also be downloaded and used for proprietary compilation or management One Point The amount of electric power purchased displayed on the Home screen or Log screen may differ from the electric powe...

Страница 22: ...ower Monitor and the Inverter are unable to communicate with each other Screens indicated with solid lines are displayed for ordinary operations Power turned on it takes about 10 seconds until the Sta...

Страница 23: ...to external internet Internet is working normally Internet time synchronization is not successful Internet time synchronization is successful Suppression icon A Suppression icon is displayed when the...

Страница 24: ...this indication Operation mode Shows the charge and discharge mode of battery Error icon An error icon is displayed to indicate that one or more errors are occurring The Error icon is ordinarily not...

Страница 25: ...if the value is 3 15 kWh then it is displayed as 3 2 kWh Thus the numerical values that are displayed do not necessarily completely match with the true value in some cases as described above Refer to...

Страница 26: ...ate month year graphs and lists The following screens are available Power log for today graph display The power status for the day can be verified Power log for today by hours list display Power log f...

Страница 27: ...ay The power status for one month can be verified Power log for one month list display Power log for one year graph display The power status for one year can be verified Power log for one year list di...

Страница 28: ...Electric power log for 20 years list display Electric power log for 20 years graph display The electric power status for 20 years can be verified 28 What Power Monitor can do...

Страница 29: ...electric power production for today The amount of electric power production today is displayed Accumulated amount of electric power production The accumulated amount of electric power production as of...

Страница 30: ...The file name hhmm represents the hour and minute at which the data was downloaded TodayLog_yyyymmdd_hhmm csv Year Month Day Hour Minute File description Date date Time time Power Production Max kW m...

Страница 31: ...t of electric power production today is displayed Accumulated amount of electric power production The accumulated amount of electric power production as of today is displayed Power production The amou...

Страница 32: ...le description Date date Time time Energy Generation kWh amount of power production Energy Consumption kWh amount of power consumed Energy Import kWh amount of power purchased Energy Export kWh amount...

Страница 33: ...of graph Graph screen Amount of Power display area Power consumption The amount of electric power consumed for current month is displayed Amount of electric power production for today The amount of e...

Страница 34: ...amount of power purchased Energy Export kWh amount of power feed in Change the display to the Home screen The details on the power amount of respective power attributes power production power consumpt...

Страница 35: ...screen Amount of Power display area Power consumption The amount of electric power consumed for current year is displayed Amount of electric power production for today The amount of electric power pr...

Страница 36: ...amount of power purchased Energy Export kWh amount of power feed in The details on the power amount of respective power attributes power production power consumption power feed in power purchase are...

Страница 37: ...tric power production today is displayed Accumulated amount of electric power production The accumulated amount of electric power production as of today is displayed Power production The amount of ele...

Страница 38: ...ded File description Year year Energy Generation kWh amount of power production Energy Consumption kWh amount of power consumed Energy Import kWh amount of power purchased Energy Export kWh amount of...

Страница 39: ...od is indicated by respective units month year Either the year or the month can be selected by touch The display by year can only be selected if there is any power production performance for that year...

Страница 40: ...Details are the same as those for respective power log graphs The details on the power amount of respective power attributes power production power consumption power feed in power purchase are display...

Страница 41: ...ed by numerical values The maximum amounts of power for 15 minute intervals are displayed Values that have been rounded up or off are displayed Date Time The date time suitable for respective performa...

Страница 42: ...15 minute increments Format CSV File name TodayLog_yyyymmdd_hhmm csv The file name yyyymmdd represents the year month and day on which the data was downloaded The file name hhmm represents the hour a...

Страница 43: ...power production power consumption power feed in power purchase are displayed by numerical values Values that have been rounded up or off are displayed Date Time The date time suitable for respective...

Страница 44: ...mmdd_hhmm csv The file name yyyymmdd represents the year month and day on which the data was downloaded The file name hhmm represents the hour and minute at which the data was downloaded File descript...

Страница 45: ...es Values that have been rounded up or off are displayed Date Time The date time suitable for respective performance displays daily monthly yearly are displayed Type of list List display screen Amount...

Страница 46: ...ded as data in 1 day increments Format CSV File name DailyLog_yyyymmdd_hhmm csv The file name yyyymmdd represents the year month and day on which the data was downloaded The file name hhmm represents...

Страница 47: ...ower purchase are displayed by numerical values Values that have been rounded up or off are displayed Date Time The date time suitable for respective performance displays daily monthly yearly are disp...

Страница 48: ...s data in 1 month increments Format CSV File name MonthlyLog_yyyymmdd_hhmm csv The file name yyyymmdd represents the year month and day on which the data was downloaded The file name hhmm represents t...

Страница 49: ...power consumption power feed in power purchase are displayed by numerical values Values that have been rounded up or off are displayed Date Time The date time suitable for respective performance displ...

Страница 50: ...the data was downloaded File description Year year Energy Generation kWh amount of power production Energy Consumption kWh amount of power consumed Energy Import kWh amount of power purchased Energy E...

Страница 51: ...verts the display to the Calendar screen Change the display to the previous month Change the display to the next month Change the display to the power history for today Touch this button will return t...

Страница 52: ...for that day Operating method Current day display The current day is indicated by a blue frame When the date in the frame is a week day it is displayed with outlined characters in a blue circle and i...

Страница 53: ...loaded Format CSV File name PlantLog_yyyymmdd_hhmm csv The file name yyyymmdd represents the year month and day on which the data was downloaded The file name hhmm represents the hour and minute at wh...

Страница 54: ...or the current month can be verified The month energy can be verified with each Inverter No Month Energy Inverter No Change the display to the Measurement values screen for energy total where the stat...

Страница 55: ...es for Inverter screen where the status of the Inverter can be verified Refer to Measurement Inverter Page 56 for details Touch the desired measurement value to switch the display to respective measur...

Страница 56: ...CSV File name DeviceXLog_yyyymmdd_hhmm csv The X in the file name is the number of the Inverter while yyyymmdd is the year for yyyy the month for mm and the day for dd on which the data is downloaded...

Страница 57: ...the number of the desired Inverter Touch the desired Inverter to switch the measurement value screens of respective Inverters Operating method Touch to display the measurement value screen of the Plan...

Страница 58: ...ower details of battery for a 1 day period as data in 15 minute increments The specific date can be selected by touch Touch the blue graph time axis the information of selected time is also displayed...

Страница 59: ...Data Maximum DC voltage The maximum DC voltage is displayed Maximum AC voltage The maximum AC voltage is displayed Current Maximum Temperature The Current Maximum value of temperature is displayed Fir...

Страница 60: ...itch the measurement value screens of respective Inverters Use to switch screens Touching this button to display another page menu Touch the desired page to switch the display to the desired screen Vo...

Страница 61: ...or orange fault red warning yellow is displayed Error code The error code is displayed Description The explanation on the description of the error is displayed Refer to the Installation and Maintenanc...

Страница 62: ...selected The yyyymmdd is the year for yyyy the month for mm and the day for dd on which the data is downloaded The file name hhmm represents the hour and minute at which the data was downloaded Detail...

Страница 63: ...splay when the equipment has been disconnected Connection cannot be established within a prescribed amount of time Yellow Display when the connection of the equipment could not be established after a...

Страница 64: ...ange the display to the first page Desired page can be selected Change the display to the previous page The status of the Inverter can be verified Refer to Information Inverter Page 59 for details The...

Страница 65: ...De rating have occurred is displayed When the interval between De rating duration and other De rating duration is within five minutes then these are counted as a single occurrence of De rating Data c...

Страница 66: ...formation Inverter Page 59 for details The error log of the Inverter can be verified Refer to Error Events Log Page 61 for details Touching this button displays another page menu Touch the desired pag...

Страница 67: ...A screen in which the desired Inverter can be selected is displayed Touch the button to display the Inverter Selection dialog box Touch the No of the desired Inverter Touch Operation Mode to switch t...

Страница 68: ...er display for the contents Once the number of characters exceeds 30 the portion leading up to the valid characters is replaced by The directory of the file is displayed with maximum of 30 characters...

Страница 69: ...d in ten levels Setting range 1 2 3 4 5 6 7 8 9 10 The default setting is 8 Slide interval The screen switching time of the slideshow can be set 5 10 20 and 30 seconds The default setting is 10 second...

Страница 70: ...ion on the Inverter can be verified Refer to Power Suppression Page 82 for details 70 A change is confirmed None of the settings will change until the Save button is touched at the end Caution is requ...

Страница 71: ...Descriptions of Respective Screens Screen 1 A world of cute illustrations with large and clear numbers Screen 2 A simple format with a simple screen 71 What Power Monitor can do...

Страница 72: ...ose Each mode has different behavior between PV battery grid and home load The following are the description of these modes In some area the detail behavior of each operation mode may be different due...

Страница 73: ...and supply home load until it s empty If you had set the time settings the behavior of hybrid inverter will change We will explain it in Page 81 Self consumption mode current flows Electrical Grid Hy...

Страница 74: ...power usage Peak cut mode current flows Electrical Grid Hybrid Inverter Battery Input or output Charge or discharge Input Output Home Load PV Array Peak cut mode behavior 19 00 12 00 07 00 00 00 24 0...

Страница 75: ...r will change behavior in these time intervals Please refer to page 81 chapter for more detail about time settings Selling first mode current flows Selling first mode behavior Electrical Grid Hybrid I...

Страница 76: ...y will not discharge in this mode even if there is no PV power Charge first mode current flows Charge first mode behavior Electrical Grid Hybrid Inverter Battery Input or output Charge or standby Inpu...

Страница 77: ...V power until it is empty Discharge first mode current flows Electrical Grid Hybrid Inverter Battery Input or output Discharge or standby Input Output Home Load PV Array Discharge first mode behavior...

Страница 78: ...hybrid inverter acts like a basic grid tie PV inverter Without BT mode current flows Electrical Grid Hybrid Inverter Input or output Input Output Home Load PV Array Without BT mode behavior 19 00 12...

Страница 79: ...grid side is disconnected by inverter and home load are supported by PV and battery power as much as possible If the battery is not connected only when there has sufficient PV power can inverter ente...

Страница 80: ...reaching 30 Only in this special condition will battery be charged by grid power In normal operation mode inverter only charges the battery by PV power Forced charge mode current flows Electrical Grid...

Страница 81: ...st discharge first in the time intervals you set and return to self consumption selling first mode outside the intervals A change is confirmed None of the settings will change until the Save button is...

Страница 82: ...touch Touching the Nothing Changed button will return to the Power Suppression screen Change the display to the previous month Change the display to the next month Suppression record That displays th...

Страница 83: ...ils Sleep time brightness slideshow and language for the screen can be set Refer to Screen Setting Page 68 for details Change the display to the Home screen In the Home screen touch Touch to switch th...

Страница 84: ...ependent System is in standalone mode Off The Inverter is stop Grid lock state will show by the color of Inverter No No grid lock if purple and grid lock if yellow Error status When one or more errors...

Страница 85: ...ioning Icon Operating mode Description Error icon An error icon is displayed to indicate that one or more errors are occurring The Error icon is ordinarily not displayed and displayed when one or more...

Страница 86: ...when the system is not restored for a long period of time Suppression icon Displayed when the Inverter is being suppressed Icon Operating mode Voltage elevation suppression Temperature elevation supp...

Страница 87: ...tively Therefore the values for the accumulated amount of power may be different on a Inverter and those displayed on a Power Monitor AC Adapter is hot How hot is it getting Heating does occur under n...

Страница 88: ...r in such cases There are some variances in measurement values The Wireless Setting lamp of the Meter is illuminated red Is there an icon such as an Error icon displayed on the Power Monitor Install t...

Страница 89: ...20 H x 215 W x 32 D mm including USB Wireless Module Weight 440 g Displayed details Power production power consumption amount of power feed in and purchased calendar history Inverter information error...

Страница 90: ...66 5 D mm Weight 145 grams current sensor 150 grams cable 20 grams 47 3mm 93mm 66 5mm Model P3E Installation method Wall mounting using DIN rails Rated operating voltage Tripple phase 4 wire 220V 230...

Страница 91: ...reless Set 5 3 Wireless Communication Unit Wireless Set Model N1E Installation method Wall mounting using DIN rails Data communication method Wireless communication Rated operating voltage DC 3 3 V Po...

Страница 92: ...C no freezing permitted Operating humidity range 0 to 90 no condensation permitted Dimensions 167 mm x 80 3 mm cover and antenna 77 mm antenna Weight 130 grams including antenna 5 5 Wireless Communica...

Страница 93: ......

Страница 94: ......

Страница 95: ......

Страница 96: ...20180529...