![Delta R2-EC 004 Series Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/delta/r2-ec-004-series/r2-ec-004-series_user-manual_2472783033.webp)
Wiring and Installation R2-ECx004 User Manual
3-8
3
(3)
The installation is complete.
DIN
3.4.2 Wiring requirements
1.
The recommended wire gauge for wiring with the housing connector or terminal block is
26 to 18 AWG.
2.
The recommended length for exposed wire is 8 mm to 9 mm (0.31” to 0.35”).
3.
Pay attention to the following when wiring with wire ferrules.
Use a correct crimping tool (such as Dinkle DNT13-0101).
The recommended length for L1 is 8 mm to 10 mm (0.31” to 0.39”).
The recommended diameter (D1) is 0.75 mm to 1.4 mm (0.03” to 0.06”).
L1
D1 (
Φ
)
Содержание R2-EC 004 Series
Страница 6: ...SDO Abort Codes 6 1 SDO abort codes 6 2 6 ...
Страница 7: ... This page is intentionally left blank ...
Страница 25: ...Specifications and Product Interface R2 ECx004 User Manual 2 16 2 This page is intentionally left blank ...
Страница 39: ...CiA 401 Device Profile R2 ECx004 User Manual 4 6 4 This page is intentionally left blank ...
Страница 64: ...6 1 SDO Abort Codes This chapter introduces the SDO abort codes for R2 ECx004 000 6 1 SDO abort codes 6 2 ...
Страница 66: ...1 Revision History Release date Version Chapter Revision contents November 2022 V1 0 First edition ...
Страница 67: ...Revision History R2 ECx004 User Manual 2 This page is intentionally left blank ...