LTL3000 User Manual / June 2020
21
DELTA
Do not insert the battery in the charger if the battery is cracked. Using a damaged battery may result in
electric shock or fire.
See further details in the battery user guide.
Safety precautions:
•
The battery should be protected against impact. Do not open the battery.
•
Store the battery in a dry and clean place.
•
Due to environmental protection do not dispose the battery with household waste.
Battery charger
A battery charger is provided as a standard accessory for charging the battery from the mains. The battery
charger comes in two models:
•
Bosch AL1130CV, 230V AC, 50/60 Hz
•
Bosch BC330 Fast Charger, 120V AC, 60 Hz
The battery will be fully charged in approx. 1hour and 15 minutes (3Ah battery).
Due to the intelligent charging method, the charging condition of the battery is automatically detected, and
the battery is charged with the optimum charging current, depending on battery temperature and voltage.
To recharge the battery, first make sure that the LTL3000 is turned off, remove the battery from the handle
and insert it in the charger. Make sure the battery and battery charger are clean and dry before and during
charging takes place.
The battery charger will during charging give the following information:
Charger AL1130CV
•
If the
green
indicator light is ‘
on
’, the charger is plugged in, but the battery is not inserted, or the
battery is fully charged and is being trickle charged.
•
If the
green
indicator light is
‘flashing’
, the battery is being fast charged. Fast-charging will
automatically stop when the battery is fully charged.
Note
: The rapid-charging procedure is only possible when the battery temperature is within the
allowable charging temperature range (see below).
•
If the
red
indicator light is
‘flashing’
, the battery cannot accept a charge. The battery may be defect
or the contacts of the charger or battery are contaminated. Clean the contacts of the charger or
battery and check. Change the battery is no solution can be found.
•
If the
red
indicator light is ‘
on
’, the temperature of the battery is not within the allowable charging
temperature range. As soon as the allowable charging temperature range is reached, the battery
charger automatically switches to rapid charging.
Charger BC330
•
If the
green
indicator light is ‘
off
’, the charger is not receiving power from power supply outlet.
•
If the
green
indicator light is ‘
on
’, the charger is plugged in, but the battery is not inserted, or the
battery is fully charged, or the battery is too hot or cold for fast charging. The charger will
automatically switch to fast charging once a suitable temperature is reached.
•
If the
green
indicator light is ‘
flashing
’, the battery is being fast charged. Fast charging will
automatically stop when the battery is fully charged.