Chapter 4 Parameter Functions
|
HES Series
4-25
02 Protection Parameters
: The parameter can be set during operation.
Software Brake Transistor Action Reference Point Setup
Control Mode
VF FOCPG
FOCPM
Factory setting: 380.0/760.0
Settings
230VSeries: 350.0~450.0Vdc
460VSeries: 700.0~900.0Vdc
Sets the reference point of software brake. The reference value is the DC bus voltage.
The last abnormal record.
The second to last abnormal record.
The third to last abnormal record.
The fourth to last abnormal record.
The fifth to last abnormal record.
The sixth to last abnormal record.
Settings
Control Mode
VF FOCPG FOCPM
0: No fault record
○
○
○
1:Over-current during acceleration (ocA)
○
○
○
2:Over-current during deceleration (ocd)
○
○
○
3:Over-current during constant speed (ocn)
○
○
○
4:Ground fault (GFF)
○
○
○
5: IGBT short-circuit (occ)
○
○
○
6: Over-current at stop (ocS)
○
○
○
7: Over-voltage during acceleration (ovA)
○
○
○
8: Over-voltage during deceleration (ovd)
○
○
○
9: Over-voltage during constant speed (ovn)
○
○
○
10: Over-voltage at stop (ovS)
○
○
○
11: Low-voltage during acceleration (LvA)
○
○
○
12: Low-voltage during deceleration (Lvd)
○
○
○
13: Low-voltage during constant speed (Lvn)
○
○
○
14: Stop mid-low voltage (LvS)
○
○
○
15: Phase failure protection (PHL)
○
○
○
16: IGBT over-heat (oH1)
○
○
○
17: Heat sink over-heat (oH2)(for 40HP above)
○
○
○
18: tH1o (TH1 open: IGBT over-heat protection error)
○
○
○
19: tH2o (TH2 open: capacitance over-heat protection error)
○
○
○
20: Fan error signal output
○
○
○
21: over-load (oL) (150% 1Min)
○
○
○
22: Motor over-load (EoL1)
○
○
○
23: Reserved
24: Motor PTC overheat (oH3)
○
○
○
25: Reserved