Pump Settings
Pump Settings
Proportional pressure control
During operation the pump is running according to the
proportional pressure curve set. The differential pressure is
controlled through the pump depending on the delivery current.
The proportional pressure characteristics are named PD1 to PD4
in the corresponding Q/H diagrams.
Constant speed control
The constant speed control characteristics are named I to III in
the Q/H diagrams. When selecting constant speed control the
pump speed does not change over the entire cycle.
Automatic night setback
Requirements for automatic night setback
Pumps installed in gas water heaters which only
contain a small amount of water must not be set to
night setback.
Note
If the heating system does not deliver sufficient water
to the radiators, please check whether the automatic
night setback is activated. If necessary, switch off the
night setback.
The following requirements must be fulfilled to ensure proper
working of the night setback:
1. The pump must be installed in the advance flow.
2. The heating system must be equipped with an automatic
advance flow temperature control.
12
E
ng
lis
h
Delta HE neutral_d_f_nl_gb_13-10-14_A6:A5 12.11.2014 14:51 Seite 48
Содержание HE 35 Series
Страница 3: ...EG Konformitätserklärung 3 Deutsch Delta HE neutral_d_f_nl_gb_13 10 14_A6 A5 12 11 2014 14 50 Seite 3 ...
Страница 15: ...Déclaration de conformité CE 3 Français Delta HE neutral_d_f_nl_gb_13 10 14_A6 A5 12 11 2014 14 50 Seite 15 ...
Страница 27: ...EG conformiteitverklaring 3 Nederlands Delta HE neutral_d_f_nl_gb_13 10 14_A6 A5 12 11 2014 14 51 Seite 27 ...
Страница 39: ...EC Conformity Declaration 3 English Delta HE neutral_d_f_nl_gb_13 10 14_A6 A5 12 11 2014 14 51 Seite 39 ...