7
HELPLINE No. U K / N.IRELAND 0800 328 6020 REP. IRELAND 00800 4467 5888
WEB SUPPORT [email protected]
GT-ZSm-01
Note
- If you want the connected device to remain switched on, push the lateral switch until
you can see the on symbol .
- Push back the switch to the former position (the clock symbol
becoming visible) for
again initiating switching operation with regard to time.
Usage notes
z
As soon as the timer switch is disconnected from the mains outlet or in case of power outage
the dial ("the clock") is deactivated.
z
With the current again flowing, e.g. following a power outage, the dial again starts to turn round.
The time is not automatically adjusted in this case, though.
z
Thus, check in case of longer use whether the set time corresponds to the actual time.
z
The time scale given for this mechanical timer switch is the quarter of an hour. It is not possible
to set the time as per minute. If you need to have a device switched on or off at exactly 10:08,
for example, this timer switch will not be suited to your needs. Use a digital timer switch
instead.
CLEANING
ATTENTION
Unplug the timer switch from the mains before cleaning the switch or its connected
device.
X
When required, wipe the timer switch clean with a soft, dry cloth.
TECHNICAL DATA
Name:
Mechanical timer
Power supply:
220 - 240 V ~ 50 Hz
Protection class:
1
Switching load:
13 A (ohmic load) / 2 A (inductive load)
Ambient temperature:
0 °C to +40 °C
Circuit breaker:
Micro interrupt
Ohmic load:
max. 3,120 W
UK Zeitschaluhr Innen.book Seite 7 Dienstag, 20. Juli 2010 2:25 14