EN-16
Specifications
Memory
1000 measurement results with respective
date and time
Dimensions
110 (L) x 57 (W) x 25 (H) mm
Power Source
3V (Two 1.5V AAA alkaline batteries)
Weight
71g
External output
Serial Cable (GD40 DELTA)
Features
Auto electrode insertion detection
Auto sample loading detection
Auto reaction time count-down
Auto switch-off after 3 minutes without
action
Temperature warning
Operating Condition
10°C to 40°C (50°F to 104°F), below 85%
R.H. (non-condensing)
Storage/Transportation
Condition
-20°C to 60°C (-4°F to 140°F), below 95%
R.H
Measurement Units
either mg/dL or mmol/L for glucose test
and fixed mmo/L for β-Ketone test
Measurement Range
10 to 600 mg/dL (0.5 to 33.3 mmol/L)
for glucose test and 0.1~8.0 mmol/L for
β-Ketone test
Hematocrit range
0~70% for glucose testing and 10~70% for
β-Ketone test
Test Sample
Capillary whole blood
Test Result
Glucose measurements are reported as
plasma equivalents
This device has been tested to meet the electrical and safety requirements
of: IEC/EN 61010-1, IEC/EN 61010-2-101, EN 61326-1, IEC/EN 61326-2-6, EN
301 489-17, EN 300 328.
WARRANTY TERMS AND CONDITIONS
With respect to disposable products, Bruno Farmaceutici S.p.A.
warrants to the original purchaser that, at time of delivery, each
standard product manufactured by Bruno Farmaceutici S.p.A. shall
be free of defects in material and workmanship and, when used for
the purposes and indications described on the labeling, is fit for the
purposes and indications described on the labeling. All warranties
for a product shall expire as of the product expiration date, or if none,
after two (2) year from the original date of purchase, as long as it has
not been modified, altered, or misused. Bruno Farmaceutici S.p.A.
warranty hereunder shall not apply if:
(i) a product is not used in accordance with its instructions or if it
is used for a purpose not indicated on the labeling; (ii) any repairs,
alterations or other work has been performed by Buyer or others
on such item, other than work performed with Bruno Farmaceutici
S.p.A.’s authorisation and according to its approved procedures; or (iii)
the alleged defect is a result of abuse, misuse, improper maintenance,
accident or the negligence of any party other than Bruno
Farmaceutici S.p.A.. The warranty set forth herein is conditioned upon
proper storage, installation, use and maintenance in accordance with
applicable written recommendations of Bruno Farmaceutici S.p.A..
The warranty furnished hereunder does not extend to damage to
items purchased hereunder resulting in whole or in part from the use
of components, accessories, parts or supplies not furnished by Bruno
Farmaceutici S.p.A..