5.6 Gluing Piping To The UV Unit - 

The Inlet/Outlet PVC union tail pieces are  inch pipe size (6mm for 

overseas models). Your PVC supply piping should be glued into the union tail pieces using an appropriate 
PVC primer and PVC cement, as recommended by your supplier. Inlet piping should be supported and 
should not rest solely upon the unions, to avoid breaking the unions. The installation of valves on the inlet 
and outlet lines attached to the UV unit is recommended. If the EUV unit is located with any portion of 
the unit below the surface of the pond or pool, then VALVES ARE MANDATORY, so you may winterize or 
remove the EUV unit without draining your pool or pond. When you have completed the piping installation 
(including bypass if necessary), the final step is to plug in the unit to its power source.

5.7  Electrical Connection -

 The electrical power rating for your EUV unit is shown on the label on the 

outside of the unit. US and Canadian EUV units operate on 120V/50/60 Hz – (1.15 Amps maximum). 
This low power consumption makes operating your EUV unit very economical. Therefore, you will need a 
5Amp 0V receptacle for your EUV unit to plug into. (Check the label on your overseas unit for its power 
requirement). Your EUV unit is supplied with an eight foot long weatherproof power cord terminating in either 
a -prong grounded NEMA plug, or in an optional cord connected Ground Fault Circuit Interrupter (GFCI). 
Whether you use the factory installed GFCI or install a GFCI in the electrical outlet or in the breaker panel 
serving the EUV unit power receptacle, you will need to have the unit GFCI protected. Note: Should the 
electrical power cord of your EUV unit become frayed or damaged in the future, unplug it from the power 
receptacle and replace it immediately.

If you did not order your EUV unit with the cord connected GFCI installed, you may add it in the field. You 
will need to order Part # 70-09012 (Retrofit Cord Connected GFCI Kit) from the supplier of your EUV unit. 
This kit comes complete with everything you need to install the weatherproof GFCI on the end of the EUV 
unit power cord. Easy to follow installation instructions are included with the kit and should take only a 
few minutes to complete. Verify that you have power to your electrical outlet and then plug the EUV unit 
power cord into your power outlet.

5.8

  

Intentionally Left Blank

5.9 

 

Electrical Interlock Of Pump/EA Unit - 

The EUV unit is equipped with a safety pressure switch that does 

not allow the UV bulb inside the unit to light unless there is at least 5 PSI operating pressure inside the chamber. 
This is to ensure that the bulb will not create heat when the EUV unit is empty or water is not flowing in the wet 
chamber. Such excessive heat can shorten the life of the UV bulb. Therefore, only when the pump is pumping 
water through the EUV unit wet chamber will you be able to see the UV bulb glow and confirm that it is on.

Note:

 Low pressure / psi pressure switches are available if you have a low pressure piping system (found 

most frequently in Koi pump installations). Order P/N 70-05. Without the circulation pump operating, you will 
not see the bulb light up just by plugging the EUV unit into its electrical outlet. Once the pump is pumping water 
thought the EUV unit, as confirmed by the indication of pressure on the pressure gauge, the bulb will light. To 
confirm that the bulb is indeed lit, you can view the glow of the bulb through the clear plastic union tail piece at 
the top outlet of the EUV unit. This is the only location where you should attempt to view the UV bulb while it is 
on. The PVC union tail piece screens out the harmful UV rays and can be viewed with the naked eye without 
any damage to the eyes. If the bulb is not lit, check the troubleshooting section at the end of this manual.

Содержание ELEKTRA UV E Series

Страница 1: ...ct should be installed by a professional service technician or similar person qualified in electrical equipment installation Improper installation and or operation could cause serious injury property...

Страница 2: ...cause blindness DO NOT VIEW UV BULB WHILE OPERATING OR DURING MAINTENANCE 6 The unit must be connected only to a supply circuit that is protected by a Ground Fault Circuit Interrupter GFCI If this uni...

Страница 3: ...ONTENTS 0 0 Forward 1 0 Introduction 2 0 Pre Installation 2 1 Pond Turnover Rates 2 2 Swimming Pool Turnover Rates 3 0 Desired Flow Rate Chart Swimming Pools Fountains Water Features 4 0 Desired Flow...

Страница 4: ...Electrical Enclosure Bonnet 10 4 Remove The Bulb 11 0 Additional UV Unit Maintenance 12 0 Normal Operating Results 12 1 Ponds 12 2 Swimming Pools Fountains Water Features Waterfalls 13 0 Winterizing 1...

Страница 5: ...important to provide the proper water flow rate through the EUV unit If water passes through the unit too quickly the exposure time of the microorganisms to the UV bulb produced rays will not be suff...

Страница 6: ...utlet is outdoors and open to the weather it will need to be an Outdoor type receptacle The EUV unit comes with a eight foot power cord Do not use an extension cord unless it is at least a 16 3 size c...

Страница 7: ...he pressure gauge must be installed on one side or the other of the clear tailpiece so that it will be in a vertical position when installed Installing the gauge facing upwardly when the EUV unit is o...

Страница 8: ...V unit with the cord connected GFCI installed you may add it in the field You will need to order Part 70 09012 Retrofit Cord Connected GFCI Kit from the supplier of your EUV unit This kit comes comple...

Страница 9: ...the circulation pump so that no water is flowing into the EUV unit Once the pump is shut off verify on the pressure gauge that the pressure inside the EUV unit is ZERO If any pressure is indicated on...

Страница 10: ...The UV Bulb Seat the quartz tube into the receptor at the bottom of the wet chamber The quartz tube will not go all the way down into the wet chamber unless the rounded end of the quartz tube is seate...

Страница 11: ...ic union fitting at the outlet of your EUV unit Your EUV unit is now ready for service 10 0 Scheduled UV Bulb Replacement In addition to cleaning of the quartz tube periodically annual replacement of...

Страница 12: ...chlorine odor should disappear in 2 4 days of continual operation after start up on properly sized and installed pools fountains waterfalls and water features Remember as noted before the EUV unit wil...

Страница 13: ...a chemical regiment as directed by your pool chemical supplier however you will notice a dramatic decrease in chemical usage as one of the side benefits of the EUV unit is that it attacks the chloram...

Страница 14: ...system to allow for larger outputs and flow rates beyond the capacity of a single E 40 or ES 40 unit Delta UV also manufactures a large capacity system the Elektra Max UV system that incorporates fac...

Страница 15: ...fault to ground in the electrical circuit or the EUV unit itself 18 3 The UV Bulb Stays Lit When The Pump Is Off The EUV unit is equipped with a safety pressure switch that turns the UV bulb off when...

Страница 16: ...given previously remove the quartz tube inspect it for cracks or breakage or for a bad quartz tube seal Re seal the quartz tube d Regardless of where your GFCI is located you can check the UV bulb for...

Страница 17: ...cost to the User and will be returned to the User via UPS Surface at the User s expense Delta UV shall be the sole judge in determining the cause of failure of any UV unit Units arriving in broken con...

Страница 18: ...___________________ CONTACT ____________________________________________ DATE OF INSTALLATION _________________________________ MODEL _________________ RE LAMP DATE _________________________ RE LAMP D...

Страница 19: ...19 NOTES...

Страница 20: ...SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS P N 94 35237 Rev 5 08 2008 Delta Ultraviolet Corporation 14936 South Figueroa Street Gardena CA 90248 310 577 1840 PHONE 310 305 9755 FAX CUSTOMERSERVICE DE...

Отзывы: