
DVW Series Industrial IEEE 802.11 a/b/g/n Wireless AP/WDS/Client/Gateway User Manual
2.1
USB Console Configuration
Delta DVW devices supports configuration using CLI interface, it mainly includes six parts:
1.
Exit
(Exit this CLI session)
2.
Maintenance
(some utility commands for maintenance related details)
load_default
3.
network_setting
(some utility commands for network details)
get_dns get_gateway
get_ip_address
get_ip_configuration get_subnet_mask set_dns
set_gateway set_ip_address
set_ip_configuration
set_subnet_mask view_setting
4.
restart
(restart the device)
5.
system_info_setting
(some utility commands for system information related details)
get_device_contact_info get_device_description get_device_location
get_device_name set_device_contact_info
set_device_decription
set_device_location set_device_name view_setting
6.
time_setting
(some utility commands for time related details)
get_local_time get_timeserver1 get_timeserver2
get_timezone set_local_time set_timeserver1
set_timeserver2 set_timezone
view_setting
You can use terminal software to connect to Delta DVW devices. Before you use CLI interface,
please plug USB cable on USB port with baud rate 115200. The inactivity timeout value on a serial
port connection can be configured between 0 and 160 minutes. (Value 0: disable the timeout.)
2-2
Содержание DVW SERIES
Страница 1: ......
Страница 5: ...iv Appendix B MODBUS TCP Map B 1 MODBUS TCP Map B 2 ...
Страница 6: ...v ...
Страница 14: ...DVW Series Industrial IEEE 802 11 a b g n Wireless AP WDS Client Gateway User Manual 1 8 MEMO ...
Страница 100: ...DVW Series Industrial IEEE 802 11 a b g n Wireless AP WDS Client Gateway User Manual 4 12 ...
Страница 101: ...Appendix A Private MIB Group Table of Contents A 1 Private MIB Group A 2 A 1 ...
Страница 103: ...Appendix B MODBUS TCP Map Table of Contents B 1 MODBUS TCP Map B 2 B 1 ...