background image

- 1 - 

…………………………………………………………………

 

 

ENGLISH

 

 

……………………………………………………………………

 

Thank you for choosing Delta DVP-SV

#1

/DVP-SV2

#1

. The SV/SV2 is a 28-point (16 

 12 outputs)/24-point (10  12 o 2 analog input channels) PLC 
MPU, offering various instructions and with 16k (SV)/30k (SV2) steps program memory, 
able to connect to all Slim type series extension models, including digital I/O (max. 512 
points), analog modules (for A/D, D/A conversion and temperature measurement) and 
all kinds of high-speed extension modules. 4 groups of high-speed (200 kHz) pulse 
outputs (and two axes which generate 10 kHz outputs in 24SV2) and 2 two-axis 
interpolation instructions satisfy all kinds of applications. DVP-SV/SV2 is small in size 
and easy to install. 

Note  #1:  D VP28SV11R/T  is  represented  b y  SV,  and  DVP24SV11T2  and  D VP28SV11R 2/T2/S2  are 
represented  b y  SV2. 

EN 

 DVP-SV/SV2 is an OPEN-TYPE device. It should be installed in a control cabinet 

free of airborne dust, humidity, electric shock and vibration. To prevent 
non-maintenance staff from operating DVP-SV/SV2, or to prevent an accident 
from damaging DVP-SV/SV2, the control cabinet in which DVP-SV/SV2 is 
installed should be equipped with a safeguard. For example, the control cabinet 
in which DVP-SV/SV2 is installed can be unlocked with a special tool or key. 

EN 

 DO NOT connect AC power to any of I/O terminals, otherwise serious damage 

may occur. Please check all wiring again before DVP-SV/SV2 is powered up. 
After DVP-SV/SV2 is disconnected, Do NOT touch any terminals in a minute. 
Make sure that the ground terminal 

  on DVP-SV/SV2 is correctly grounded in 

order to prevent electromagnetic interference. 

FR 

 DVP-SV/SV2 est un module OUVERT. Il doit être installé que dans une enceinte 

protectrice (boitier, armoire, etc.) saine, dépourvue de poussière, d’humidité, de 
vibrations et hors d’atteinte des chocs électriques. La protection doit éviter que 
les personnes non habilitées à la maintenance puissent accéder à l’appareil (par 
exemple, une clé ou un outil doivent être nécessaire pour ouvrir a protection).

 

FR 

 Ne pas appliquer la tension secteur sur les bornes d’entrées/Sorties, ou l’appareil 

DVP-SV/SV2 pourra être endommagé. Merci de vérifier encore une fois le 
câblage avant la mise sous tension du DVP-SV/SV2. Lors de la déconnection de 
l’appareil, ne pas toucher les connecteurs dans la minute suivante. Vérifier que la 
terre est bien reliée au connecteur de terre 

  afin d’éviter toute interférence 

électromagnétique. 

 Product Profile 

Direct fastening hole

Nameplate

[ Figure 1 ]

I/O terminal

COM1(RS-232)
program I/O 
communication 
port

Left-side module 
connection port

DIN rail clip

RUN/STOP switch

I/O indicator

VR0: M1178 

/D1178

enabled

corresponding value

VR1: M1179 enabled/D1179
corresponding value

POWER/RUN/BAT.LOW/ERROR indicator

COM1(RS-232) receiving
communication (Rx) indicator

COM2(RS-485) sending
communication (Tx) indicator

2

3

4

7

8

5

6

9

11

12

13

1

10

 

 

3PIN removable terminal
(standard component)

I/O module 
positioning hole

[ Figure 2 ]

I/O module 
connection port

COM2(RS-485) 
communication port 
(Master/Slave)

Power input port

I/O module fastening clip

Mounting slot
(35mm)

Power input connection
cable (standard component)

14

15

16

17

18

19

20

21

 

Содержание DVP-SV

Страница 1: ...2018 07 20 5011669009 SV12...

Страница 2: ...ute Make sure that the ground terminal on DVP SV SV2 is correctly grounded in order to prevent electromagnetic interference FR DVP SV SV2 est un module OUVERT Il doit tre install que dans une enceinte...

Страница 3: ...C Vibration shock immunity International standards IEC61131 2 IEC 68 2 6 TEST Fc IEC61131 2 IEC 68 2 27 TEST Ea Weight g 260 260 240 240 230 Input Point Spec Items 24VDC single common port input 200kH...

Страница 4: ...No isolation between digital circuits and analog circuits 1 If the scan cycle is longer than 2 milliseconds or greater than the setting value the scan cycle is given preference 2 If the value in D106...

Страница 5: ...0 75 C copper conductor 22 16AWG 1 5mm 2 DO NOT wire empty terminal DO NOT place the I O signal cable in the same wiring circuit 3 DO NOT drop tiny metallic conductor into the PLC while screwing and w...

Страница 6: ...C power supply output 24VDC 500mA 9 DVP PLC main processing unit 10 Digital I O module Input Point Wiring There are 2 types of DC inputs SINK and SOURCE See the example below For detailed point config...

Страница 7: ...are connected to the common terminals UP0 and ZP0 Y10 Y13 are connected to the common terminals UP1 and ZP1 See Figure 11b 4 Isolation circuit The optical coupler is used to isolate signals between t...

Страница 8: ...ff 1 DC power supply 2 Emergency stop 3 Circuit protection fuse 4 The output of the transistor model is open collector If Y0 Y1 is set to pulse output the output current has to be bigger than 0 1A to...

Страница 9: ...data storage 2 The lithium ion battery has been fully charged in the factory and is able to retain the latched procedure and data storage for 6 months If DVP SV SV2 has not been powered for less than...

Страница 10: ...O 8 VR1 M1179 D1179 19 I O 9 20 DIN 35mm 10 21 I O 11 DVP28SV11R DVP28SV11R2 DVP28SV11T DVP24SV11T2 DVP28SV11T2 DVP28SV11S2 24VDC 15 20 Max 2 2A 24VDC 2 5A 30VDC Polyswitch 6W 5M 500VDC ESD IEC 61131...

Страница 11: ...24VDC 5mA Off On 150ns 8 s On Off 3 s 60 s D1020 D1021 10 60 ms 10ms 1 A2 X10 X11 X14 X15 200kHz V2 00A2 2 24SV2 X12 X17 No Y0 Y7 Y10 Y13 Y0 Y4 Y6 Y5 Y7 Y10 Y13 1Hz 200kHz 10kHz 250VAC 30VDC 5 30VDC 1...

Страница 12: ...M4 DIN 35mm DIN I O 3 Figure 6 I O 1 22 16AWG 1 5mm 4 PLC 1 90 kg cm 1 65 in lbs 60 75 C 2 3 PLC PLC DVP SV SV2 1 24VDC 0V 20 4 28 8VDC 20 4VDC PLC Off ERROR LED 2 10ms PLC PLC Off PLC PLC DVP SV SV2...

Страница 13: ...5 Figure 11b 4 PLC 5 Figure 12 1 2 3 5 10A 4 1 DC 6 Figure 13 2 DC Zener On Off 6 Figure 14 5 6 7 Y3 Y4 PLC 8 9 6 Figure 15 6 Figure 17 Figure 18 1 2 3 4 Open Collector Y0 Y1 0 1A 1 6 Figure 19 Figur...

Страница 14: ...13 D Flash ROM WPLSoft PLC Flash D Flash ROM Flash ROM PLC Flash ROM D SRAM PLC RUN 1 DVP SV SV2 2 6 24 3 40o C 1000 6 4 5 6 BAT LOW DVP SV SV2 24 1 PLC C F 0 32 25 77 55 131 117 52 132...

Страница 15: ...O 8 VR1 M1179 D1179 19 I O 9 20 DIN 35mm 10 21 I O 11 DVP28SV11R DVP28SV11R2 DVP28SV11T DVP24SV11T2 DVP28SV11T2 DVP28SV11S2 24VDC 15 20 Max 2 2A 24VDC 2 5A 30VDC Polyswitch 6W 5M 500VDC ESD IEC 61131...

Страница 16: ...1 5mA 8V Off On 150ns 8 s On Off 3 s 60 s D1020 D1021 10 60 ms 10ms 1 A2 X10 X11 X14 X15 200kHz V2 00A2 2 24SV2 X12 X17 No Y0 Y7 Y10 Y13 Y0 Y4 Y6 Y5 Y7 Y10 Y13 1Hz 200kHz 10kHz 250VAC 30VDC 5 30VDC 1...

Страница 17: ...N 35mm DIN I O 3 Figure 6 I O 1 22 16AWG 1 5mm 4 PLC 1 90 kg cm 1 65 in lbs 60 75 C 2 3 PLC PLC DVP SV SV2 1 24VDC 0V 20 4VDC 28 8VDC 20 4VDC PLC Off ERROR LED 2 10ms PLC PLC Off PLC PLC DVP SV SV2 DC...

Страница 18: ...11b 4 PLC 5 Figure 12 1 2 3 5 10A 4 1 DC 6 Figure 13 2 DC Zener On Off 6 Figure 14 5 6 7 Y3 Y4 PLC 8 9 6 Figure 15 6 Figure17 Figure18 1 2 3 4 Open Collector Y0 Y1 0 1A 1 6 Figure 19 Figure20 2 Zener...

Страница 19: ...18 WPLSoft PLC Flash D Flash ROM Flash ROM 1 PLC Flash ROM D SRAM PLC RUN 1 DVP SV SV2 2 6 24 3 40o C 1000 6 4 5 6 BAT LOW DVP SV SV2 24 1 PLC C F 0 32 25 77 55 131 117 52 132...

Отзывы: