Chapter 8 Logic Instructions
8-207
8_
8.14.2.5
ETH_Link_Config_Ext
FB/FC
Explanation
Applicable model
FB
ETH_Link_Config_Ext is used to configure the cycle time and link
duration for MODBUS TCP data exchange.
DVP15MC11T
DVP15MC11T-06
Input Parameters
Parameter name
Function
Data type
Valid range
(Default)
Validation timing
Execute
The instruction is
executed when
Execute
changes from FALSE to
TRUE.
BOOL
TRUE or FALSE
(
FALSE
)
CycleTime
The cycle time the master
sends MODBUS TCP
data.
(Unit: milliseconds)
ARRAY [1..16]
OF UINT
0~65535
(0)
When
Execute
changes from
FALSE to TRUE.
LinkKeeptime
The link duration of the
master (Unit: seconds)
ARRAY [1..16]
OF UINT
0~65535
(
0
)
When
Execute
changes from
FALSE to TRUE.
Note:
1. Every element of the values in
CycleTime
and
LinkKeeptime
corresponds to the number in a
ETH_Link_Config instruction. For example, the first element of
CycleTime
value corresponds to the
data-sending cycle time of the number 1.
2. The unit of
CycleTime
is milliseconds (ms) and
LinkKeepTime
is seconds (s).
3.
LinkKeeptime
is the link duration (unit:seconds). If there is no data exchange between the master and
slave within the time specified by
LinkKeeptime,
, the controller will disconnect the link to the slave
automatically.
Output Parameters
Parameter
name
Function
Data type
Valid range
Done
TRUE when the instruction execution is completed.
BOOL
TRUE / FALSE
Output Update Timing
Parameter
Name
Timing for changing to TRUE
Timing for changing to FALSE
Done
When
Execute
changes to
TRUE.
When
Execute
changes from TRUE to
FALSE.
Function
When the MODBUS TCP master function of the controller is used, ETH_Link_Config_Ext can be used
to set the cycle time and link duration for MODBUS TCP data exchange. The firmware of V1.01 and
above supports the function.
1. The ETH_Link_Config_Ext instruction can be used to set the cycle time and link duration for MODBUS
TCP data exchange. The instructon can also be used in the configuration of MODBUS TCP parameters.
And it can still be used in the MODBUS TCP master function of the controller. One piece of MODBUS
TCP data sending is finished and then another piece will be sent out immediately. The link duration is
E T H_Link_Config_Ext
Execute
E T H_Link_Config_Ext_instance
CycleTime
Done
LinkKeeptim e
Содержание DVP-15MC Series
Страница 16: ...1 1 1 Preface Table of Contents 1 1 Explanation of Symbols in This Manual 1 2 1 2 Revision History 1 3...
Страница 19: ...DVP 15MC Series Motion Controller Operation Manual 1 4 _1 MEMO...
Страница 20: ...2 1 2 Overview Table of Contents 2 1 Product Description 2 2 2 2 Functions 2 2 2 3 Profile and Components 2 3...
Страница 23: ...DVP 15MC Series Operation Manual 2 4 _2 MEMO...
Страница 31: ...DVP 15MC Series Motion Controller Operation Manual 3 8 _3 MEMO...
Страница 75: ...DVP 15MC Series Motion Controller Operation Manual 6 26 _6 MEMO...
Страница 87: ...DVP 15MC Series Motion Controller Operation Manual 7 12 _7 MEMO...
Страница 432: ...Chapter 8 Logic Instructions 8 345 8_ MEMO...
Страница 433: ...9 1 9 Chapter 9 Introductions of Axis Parameters Table of Contents 9 1 Description of Axis Parameters 9 2...
Страница 470: ...DVP 15MC Series Motion Controller Operation Manual 10 34 10 MEMO...
Страница 878: ...DVP 15MC Series Motion Controller Operation Manual 11 408 11 1 MEMO...
Страница 920: ...DVP 15MC Series Motion Controller Operation Manual A 16 A MEMO...
Страница 941: ...D 1 D Explanation of Homing Modes Table of Contents D 1 Explanation of Homing Modes D 2...
Страница 966: ...DVP 15MC Series Motion Controller Operation Manual D 26 D MEMO...