TECHNICAL DATASHEET

 

Sync DIN Rail Power Supply 

12V 50W 1 Phase (NEC Class 2) / DRS-12V50W1N

□ 

 
 

  

All parameters are specified at 25°C ambient and AC input unless otherwise indicated.

 

  www.DeltaPSU.com (March 2016, Rev. 00)  

 

13

 

Operating Mode 

 

 

Parallel Operation 

 

 

 
 
 
 

Others 

Delta RoHS Compliant 

Restriction of the usage of hazardous substances 

The European directive 2011/65/EU limits the maximum impurity level of homogeneous materials such as lead, 
mercury, cadmium, chrome, polybrominated flame retardants PBB and PBDE for the use in electrical and 
electronic equipment. RoHS is the abbreviation for “Restriction of the use of certain hazardous substances in 
electrical and electronic equipment”. 

This product conforms to this standard. 

 
 

 

Fig. 3 

 Parallel Operation Connection Diagram 

 

The power supply units (PSUs) can also be used for 
parallel operation in order to increase the output power. 
The difference in output voltage between the two units 
must be kept to within 25mV of each other. This 
difference must be verified with  the same output load 
connected independently to each unit. 

Parameters such as EMI, inrush current, leakage current, 
PARD, start up time will be different  from those on the 
datasheet, when two units are connected in parallel. The 
user will need to verify that any differences will still allow 
the two power supplies connected in parallel will work 
properly in their product/application. 
 

Содержание DRS-24V30W-1AZ

Страница 1: ...wer supply is designed for industrial applications requiring highly reliable power supply that must fit in a small space The Sync series operates with universal AC input range and offers full power up...

Страница 2: ...Voltage 12Vdc Factory Set Point Tolerance 12Vdc 2 Output Voltage Adjustment Range 12 15Vdc Output Current 4A 48W max Output Power 48W Line Regulation 0 5 85 264Vac 100 load Load Regulation 1 0 85 264V...

Страница 3: ...3 C Operating Humidity 5 to 95 RH Non Condensing Operating Altitude 0 to 2 000 Meters 6 560 ft Shock Test Non Operating IEC60068 2 27 Half Sine Wave 50G for a duration of 11ms 3 times per direction 9...

Страница 4: ...ty Standards Directives Safety Entry Low Voltage SELV EN 60950 Electrical Safety TUV Bauart UL cUL recognized CB Scheme EN 60950 1 UL 60950 1 CSA C22 2 No 60950 1 File No E191395 IEC 60950 1 Limited P...

Страница 5: ...2kV Surge IEC 61000 4 5 Level 3 Criteria A 1 Common Mode 3 2kV Differential Mode 4 1kV Conducted IEC 61000 4 6 Level 3 Criteria A1 150kHz 80MHz 10Vrms Power Frequency Magnetic Fields IEC 61000 4 8 Cri...

Страница 6: ...IN Rail Power Supply 12V 50W 1 Phase NEC Class 2 DRS 12V50W1N All parameters are specified at 25 C ambient and AC input unless otherwise indicated www DeltaPSU com March 2016 Rev 00 6 Block Diagram DR...

Страница 7: ...March 2016 Rev 00 7 Device Description DRS 12V50W1NZ 1 Input terminal block connector 2 Output terminal block connector 3 DC voltage adjustment potentiometer 4 DC OK LED Green 5 Universal mounting sys...

Страница 8: ...RS 12V50W1N All parameters are specified at 25 C ambient and AC input unless otherwise indicated www DeltaPSU com March 2016 Rev 00 8 Dimensions L x W x D 75 x 30 x 89 5 mm 2 95 x 1 18 x 3 52 inch DRS...

Страница 9: ...til the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition and require removal re application of input AC voltage in order to res...

Страница 10: ...sk of explosion severe damage To guarantee sufficient convection cooling keep a distance of 80mm 3 14 inch above and below the device as well as a lateral distance of 25mm 0 98 inch to other units Not...

Страница 11: ...to 90 of its final steady state set value Hold up Time Time between the collapse of the AC input voltage and the output falling to 95 of its steady state set value Inrush Current Inrush current is the...

Страница 12: ...output current will operate in Hiccup mode The power supply will return to normal operation after the short circuit is removed Overvoltage Protection Latch Mode The power supply s overvoltage circuit...

Страница 13: ...n of the use of certain hazardous substances in electrical and electronic equipment This product conforms to this standard Fig 3 Parallel Operation Connection Diagram The power supply units PSUs can a...

Отзывы: