TECHNICAL DATASHEET
CliQ II DIN Rail Power Supply
24 V 240 W 2 Phase / DRP-24V240W2BN
All parameters are specified at 25°C ambient and AC x 2 input unless otherwise indicated.
www.DeltaPSU.com (September 2021, Rev. 06)
5
EMC
Emissions (CE & RE)
Generic Standards: CISPR 32, EN/BS EN 55032, CISPR 11,
EN/BS EN 55011, FCC Title 47: Class B
Component Power Supply for General Use
EN/BS EN 61204-3
Immunity
Generic Standards: EN/BS EN 55024, EN/BS EN 61000-6-2
Electrostatic Discharge
IEC 61000-4-2 Level 4 Criteria A
1)
Air Discharge: 15 kV
Contact Discharge: 8 kV
Radiated Field
IEC 61000-4-3 Level 3 Criteria A
1)
80 MHz-1 GHz, 10V/M, 80% modulation (1 kHz)
1.4 GHz-2 GHz, 3V/M, 80% modulation (1 KHz)
2 GHz-2.7 GHz, 1V/M, 80% modulation (1 KHz)
Electrical Fast Transient / Burst
IEC 61000-4-4 Level 3 Criteria A
1)
2 kV
Surge
IEC 61000-4-5 Level 3 Criteria A
1)
Common Mode
2)
: 2 kV
Differential Mode
3)
: 1 kV
Conducted
IEC 61000-4-6 Level 3 Criteria A
1)
150 kHz-80 MHz, 10 Vrms
Power Frequency Magnetic Fields
IEC 61000-4-8 Criteria A
1)
30 A/Meter
Voltage Dips and Interruptions
IEC 61000-4-11 100% dip; 1 cycle (20 ms); Self Recoverable
Low Energy Pulse Test (Ring Wave)
IEC 61000-4-12 Level 3 Criteria A
1)
Common Mode
2)
: 2 kV
Differential Mode
3)
: 1 kV
Harmonic Current Emission
IEC/EN/BS EN 61000-3-2, Class A
Voltage Fluctuation and Flicker
IEC/EN/BS EN 61000-3-3
1) Criteria A: Normal performance within the specification limits
2) Asymmetrical: Common mode (Line to earth)
3) Symmetrical: Differential mode (Line to line)