I

NTRODUCTION

 

 

Delta DE212 is a deadman system for aircraft refuelling trucks and dispensers. The DE212 system can operate 
wireless or wired. 
This document describes the CU212-1S, the control unit installed in the drivers cabin, and the  
CB212-1S, the handheld unit, which are the two main components of the wired deadman.  
The wired deadman differs from the wireless as it needs a cable connection between the two units to carry the 
needed signals.  
The DE212-1S/F wired deadman is designed for failsafe operation.  
The DE212-1S wired system is designed to operate the deadman valve and also comprises a stop button on the 
handheld unit, making it possible to "emergency-stop" the refuelling from a remote position. 
The DE212 has a built in timer system, with timeout warning outputs for light and beeper. The standard timer is 
set to 2 minutes with the warning signals 30 seconds before the refuelling will shut down.  
If the control unit is connected to a simple ON-OFF handswitch, the control unit has to be set to none failsafe 
operation, this can be selected by a qualified technician. 
With more than 15 years of experience in developing and producing deadman systems, the DE212 system has all 
the security needed for a safe and reliable operation. 
 
For special applications, the control unit has inputs for deadman function override and STOP.  
 
The DE212 system is based on the latest technology and has the flexibility to meet new operational demands by 
upgrading the software in the control unit. 

 

1.1

 

S

YSTEM DIAGRAM

 

 

 
 
 

 

 

 

 

 

 

 

 
 
 

 

 

 

 
 

 

 

 

 
 

   Wired Deadman System Diagram 

                                              (Not to scale) 

 
 
 
 
 
 
 
 
 
 
 

12/24VDC 

 

Valve control 

Emergency  STOP 

Interlock 

Warning buzzer 

CB212-1S/F 

CU212-1S/F 

 

Cable stretchable to 14m 

(From additional junction box) 

Warning light 

Содержание DE212 GLOBAL

Страница 1: ...P O Box 1065 S ndre Kuller d 4A Web site www deltarc no Last revision 18 08 2017 N 3204 Sandefjord E mail hello deltarc no Norway Delta DE212 Failsafe Wired Deadman Control for Aero Plane Refuelling T...

Страница 2: ...3 INSTALLING THE CONTROL UNIT 6 2 4 CABLE CONNECTION TO HANDHELD UNIT 6 3 OPERATION 7 3 1 UNIT DESCRIPTION 7 3 2 FUNCTION DESCRIPTION 8 3 3 MAINTENANCE 10 4 SPARE PARTS 10 5 WARRANTY CONDITIONS 11 6 T...

Страница 3: ...mote position The DE212 has a built in timer system with timeout warning outputs for light and beeper The standard timer is set to 2 minutes with the warning signals 30 seconds before the refuelling w...

Страница 4: ...onnected as described See figure below Connections to the PCB in the control unit P1 Output Signals 1 DC output signal to horn beeper 2 Warning light signal 3 Not in use Do not connect 4 Deadman outpu...

Страница 5: ...hold for more than 3 sec when switching on the control unit After this 3 sec the green ON led on the front turns on lights up indicating that the process is finished successful When the control unit...

Страница 6: ...board and connect the cables to the connectors while they are free to move and easy to keep in the right position When all cables are connected replace the connectors to the printed circuit board and...

Страница 7: ...consists of the following parts CU212 1S control unit for installation in the drivers cabin CB212 1S handheld switch Connection box optional not included in the delivery 14m coiled cable not included...

Страница 8: ...e design telling that the system will stop if something goes wrong That is for instance if the cable short circuits This will immediately shut down the fuelling The wired deadman is normally delivered...

Страница 9: ...it is powered this output is active supplying 12 24V When the STOP button is activated this output is switched off If the cable is shorted this output is also switched off Warning light output Is acti...

Страница 10: ...equipment housing is damaged Dirty equipment should therefore always be cleaned As a rule the equipment should be sent to service as quick as possible when such damages occurs without waiting till the...

Страница 11: ...t the customer s location there will be charges for cost of travelling accommodation and dieting conforming to the government s assertions There will also be an additional charge of 50 of travelling t...

Страница 12: ...arning light output active during operation of the deadman Beeper warning output STOP output When control unit is powered this output is active output is12 24V When STOP is detected this output is swi...

Страница 13: ...User and Installation Manual for DE212 1S Wired Deadman DELTA RCS AS Page 13 of 17 Document 02002 6 4 DIMENSIONS 6 4 1Control Unit All dimensions in mm...

Страница 14: ...User and Installation Manual for DE212 1S Wired Deadman DELTA RCS AS Page 14 of 17 Document 02002 6 4 2 Handswitch All dimensions in mm...

Страница 15: ...2 1S Wired Deadman DELTA RCS AS Page 15 of 17 Document 02002 6 4 3 Wall mount for Handswitch All dimensions in mm Delta RC AS AS reserves the right to change the specifications and upgrade its product...

Страница 16: ...thing powered by an electrical source e g from a power socket or a battery The batteries should be disposed properly at a battery recycling facility The housings should be disposed as general waste Pl...

Страница 17: ...Kuller d 4A E mail hello deltarc no NO 3204 Sandefjord Norway www deltarc no Delta RC AS reserves the right to make changes without further notice to the product to improve reliability functions and d...

Отзывы: