Tools Required for Assembly (not included): Hammer, 

Flathead Screwdriver, Wire Nuts, Nails, Duct Tape, 

Phillips Head Screwdriver, Utility Knife  

Helpful Tools (not included): Electric Drill, Drill Bits

WARNING: Turn off electricity at breaker box 

before beginning installation.

  Carefully remove unit from carton.
  Check area above installation location to be sure 

that wiring can run to the planned location and 

that duct work can be run. Make sure the area is 

sufficient for proper ventilation.

  Inspect duct work and wiring before proceeding 

with installation.

  Before installation, provide inspection and future 

maintenance access at a location that will not 

interfere with installation work.

  You may need the help of a second person to 

install this fan: one person on the attic side and 

one on the room side.

Note: Installations may vary depending on how the 

previous bath fan was installed. Supplies necessary 

for the installation of your bath fan are not all included. 

However, most are available at your local home 

improvement or hardware store.

Proper insulation around the fan to minimize building 

heat loss and gain. 4” circular duct is recommended 

for installation. The ducting from this fan to the 

outside of building has a strong effect on air flow, 

noise and energy use of the fan. Use the shortest, 

straightest duct routing possible for best performance, 

and avoid installing the fan with smaller ducts than 

recommended. Insulation around the ducts can 

reduce energy loss and inhibit mold growth. Fans 

installed with existing ducts may not achieve their 

rated air flow.

  

The fan will operate most efficiently when located 

where the shortest possible duct run and minimum 

number of elbows will be needed.

  Use a roof cap or wall cap that has a built-in 

damper to reduce backdrafts.

  External timer/dimmer switch can be used. Please 

contact Delta Breez customer service and consult 

with a licensed electrician for compatibility.

PREPARATION

JUNCTION BOX

SWITCH BOX

OFF

OFF

ON

ON

BLACK

POWER SWITCH

L

L

N

N

GRD

WHITE

LIGHT SWITCH

RED

WHITE

GREEN

Roof cap

(with built-in

damper)

Seal gap

around 

housing

Caulk termination

to duct

Fan housing

Short piece of flexible

duct helps alignment

and absorbs sound

or

Wall cap

(with built-in

damper)

Wall cap

(with built-in

damper)

2~3 ft straight run 

before elbow

SWITCH BOX

ON/OFF SWITCH

(purchase separately)

POWER 

SWITCH

RED

BLACK

GROUND

(bare)

120 VAC

LINE IN

WHITE

WIRING

PLATE

LIGHT 

SWITCH

WIRING DIAGRAM

Содержание breez 110LED-ADJ

Страница 1: ...ly Instructions Existing Construction Grille Installation Care and Maintenance Troubleshooting Dimensions Product Specifications Warranty 2 3 4 5 6 10 11 12 13 13 14 READ AND SAVE THESE INSTRUCTIONS A...

Страница 2: ...T DESCRIPTION QTY 1 Fan Body 1 2 Grille 1 3 Suspension bracket 13 318 5mm 2 4 Suspension bracket 13 318 5mm 2 5 Duct Connector 1 HARDWARE CONTENTS Images are to scale 4 Long Wood Screw 4 x 25mm 4 Shor...

Страница 3: ...cient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and s...

Страница 4: ...ular duct is recommended for installation The ducting from this fan to the outside of building has a strong effect on air flow noise and energy use of the fan Use the shortest straightest duct routing...

Страница 5: ...o ceiling joists NO NEED FOR SUSPENSION BRACKETS Hardware A Long wood screw 3 For joist spacing 16 in 24in insert suspension bracket I 3 and suspension bracket II 4 into the bracket cover on the duct...

Страница 6: ...duct a not supplied and vent to the outside Secure it with duct tape not supplied or clamp not supplied to make the connection secure and air tight 6 Punch out Mask from packaging Insert mask and fin...

Страница 7: ...4 Remove fan unit by removing 3 screws 5 A piece of wood not supplied is screwed in from below through the ceiling board Suggested size is 1 in x 3 in x 14 in Position the screws far enough away from...

Страница 8: ...using can from below by using 2 long wood screws through the flange into the wood support and 2 long wood screws through the flange into the joist Hardware A Long wood screw 8 Attach the duct connecto...

Страница 9: ...ension brackets to the joists with nails and secure the suspension brackets to the fan body 1 by using the short screws provided Hardware B Short screw 2 Remove the fan junction box cover a Using wire...

Страница 10: ...k of grille choose the color temperature you want for your LED You can choose from 2700K warm white 4000K cool white and 5000K daylight white Attach grille 2 by pinching mounting springs a and insert...

Страница 11: ...se resin parts in water over 140 Fahrenheit Turn off power source Review all safety precautions 1 To remove grille 2 squeeze springs and pull down 2 Clean the grille 2 in a sink and dry with a cloth 3...

Страница 12: ...er has become damaged please call Customer Service 3 Be sure you do not have any sharp bends in duct closer than 18 in to the fan discharge 4 Use recommended size ducting to reduce fan noise 5 Be sure...

Страница 13: ...cy Hz Air Flow 0 1 SP CFM Power 0 1 SP W Max Current Amps Weight lb Note Light Spec 110LED ADJ VFB110D4LED3 A 120 60 110 14 8 0 48 10 Single Speed 13W LED 850 Lumens 2700K 4000K 5000K Note Design and...

Страница 14: ...idental consequential punitive or special damages arising out of or in connection with products use or performance regardless of the form of action whether in contract tort including negligence strict...

Отзывы: