5.Wiring

No.

Color

Marks

Description

1

Green 

D0

Wiegand input ( Wiegand output as reader mode)

2

White

D1

Wiegand input ( Wiegand output as reader mode)

3

Yellow

OPEN

Exit button input end

4

Red

+12V

Positive power supply 

5

Black

GND

Negative power supply

6

Blue

NO

Relay NO end

7

Purple

COM

Relay COM end

8

Orange

NC

Relay NC end

6. Diagram

6.1 Common Power Supply

Содержание ATLO-RM-822

Страница 1: ...Large Capacity Access Control Proximity Card Reader ...

Страница 2: ... admin delete card and setting card 10 000 card users The unlocking signal adopts NO NC COM output of relay 3 Technical Specifications Operating Voltage DC 12 24V Standby Current 35mA Operation Current 100mA Operating Temperature 20 60 Operating Humidity 0 95 Maximum Rated Current 1A Door Relay Time 0 99s adjustable Dimension 120 56 20mm 4 Installation Remove the back cover from the keypad using t...

Страница 3: ...s reader mode 2 White D1 Wiegand input Wiegand output as reader mode 3 Yellow OPEN Exit button input end 4 Red 12V Positive power supply 5 Black GND Negative power supply 6 Blue NO Relay NO end 7 Purple COM Relay COM end 8 Orange NC Relay NC end 6 Diagram 6 1 Common Power Supply ...

Страница 4: ...ht Indication Operation Status Light indicator Buzzer Stand by Red Operation successful Green Beep Operation failed Beep Beep Beep Admin card enter programming Beep Beep Admin card exit programming Beep Press key Beep Data backup Green indicator flash slowly ...

Страница 5: ...d setting card Green indicator light flash slowly Operation by Remote controller 1 Add Users Remarks Change admin code Admin code 0 New code Repeat new code Default admin code 999999 Add card user Admin code 1 Read card Read card continuously to add card user Add card number user Admin code 1 8 digits 10 digits card number 2 Delete Users Delete card user Admin code 2 Read card or 8 digits 10 digit...

Страница 6: ...once the indicator light turns red it means you have exited the delete user programming 10 Data Backup Operation Example Backup the data of machine A to machine B Machine A uses admin card of A machine B uses admin card of B The green wire and white wire of machine A connects with the green wire and white wire of machine B correspondingly set B for receiving mode at first then set A for sending mo...