background image

6.0  Connecting mains power to the AlertMaxx unit

For technical support, please call 01279 757400

AlertMaxx

1.  Replace the far right blanking plug (large) with a large cable gland.

2.  Feed the mains power cable through the right hand cable gland (large) and connect the power cable    

 

to the terminal strip (see figure 2).

CAUTION! - Ensure mains power is isolated before connecting it to the AlertMaxx unit and seek 

advice from a qualified electrician.

Figure 2. Connecting mains

BLUE

BLACK

E

N

L

40

120

20

70

50

80

7.0  Installing the float switch in the chamber

Care must be taken to ensure the correct type of float switch is installed into the chamber. Figures 3 & 4 

show the two float switch options.

7.1 

Installing a finger float into a ground or surface water chamber

1.  Using the nut and washer provided, secure the finger float to the inside of the float housing so that the   

 

float rises with rising water levels (see figure 5).

2.  Using the two cable ties provided, attach the float housing to the discharge arm so it is 300mm from the  

 

base of the chamber (see figure 6).

Содержание AlertMaxx DMS-269

Страница 1: ...AlertMaxx Installation Operating Instructions For Ground Water DMS 270 and Foul Water DMS 269 T 01992 523532 E info deltamembranes com W www deltamembranes com Pump Station High Level Alarm...

Страница 2: ...AlertMaxx...

Страница 3: ...axx unit 6 7 0 Installing the float switch in the chamber 7 7 1 Installing a finger float into a ground or surface water chamber 7 7 2 Installing a pendant float into a foul water chamber 7 8 0 Connec...

Страница 4: ...4 For technical support please call 01279 757400 AlertMaxx Groundwater version DMS 270 1 x Finger Float Switch 1 x Finger Float Housing 2 x Cable Ties Foul Water version DMS 269 1 x Pendant Float Swit...

Страница 5: ...Mounting instructions 5 1 Mounting the AlertMaxx unit 1 Using the template provided on page 15 of this instruction manual figure 1 mark the fixing positions on the wall 2 Drill the two holes and fit...

Страница 6: ...rom a qualified electrician Figure 2 Connecting mains E N L 7 0 Installing the float switch in the chamber Care must be taken to ensure the correct type of float switch is installed into the chamber F...

Страница 7: ...ttom of the float switch to hang approximately 350mm above the base of the chamber see figure 7 Suitable for ground surface water Suitable for foul water E N L Option 2 Guide rail mounted foul pump 1...

Страница 8: ...in the chamber 8 For technical support please call 01279 757400 AlertMaxx Figure 6 Ground Water Sump DMS 164 Figure 5 Ground Water Float Switch Figure 7 Foul Water Sump DMS 165 Figure 8 Foul Water Flo...

Страница 9: ...he small cable gland When using the pendant float switch figure 4 use the large cable gland 3 Connect the float switch cable to the terminal strip When using the finger float figure 3 connect the blue...

Страница 10: ...8 0 Connecting the float switch to the AlertMaxx unit 10 For technical support please call 01279 757400 AlertMaxx Figure 10 Wiring a pendant float switch BLUE BLACK...

Страница 11: ...three times 4 Check that the green LED flashes every second and after one minute the unit emits a short beep followed by a flash from the red LED every 5 seconds 5 Turn on the mains power supply to th...

Страница 12: ...rnal devices such as an alarm or beacon When the alarm is activated the relay sends a signal once every second The volt free relay is designed to accept devices with a maximum load of 0 5A and voltage...

Страница 13: ...ET button However the beep will return 7 days from pressing the RESET button until a service technician resets the alarm unit The AlertMaxx unit has a factory default service interval of 12 months 12...

Страница 14: ...arge the battery by connecting mains supply to alarm unit Still doesn t turn on after 3 mins alarm unit is faulty The LEDs flash in the following order red blue green Low battery charge the battery by...

Страница 15: ...AlertMaxx For technical support please call 01279 757400 15 Figure 1 Scale 1 1 Mounting hole positions Top Bottom...

Страница 16: ...ed on time professionally fitted and offers hassle free on going operation and maintenance PPS Precise Passionate Service Precise Fully trained in house service engineers to maintain enhance and repla...

Отзывы: