AG9032 v1 Spine and Leaf Switch

Chapter 3: Installation

3.1 Mounting

This switch can be mounted in a standard 19-inch equipment rack or on a horizontal surface. 
Mounting instructions for each type of site follow.

3.1.1  Rack Mounting

Prior rack mounting the switch, pay particular attention to the following factors:

 

Mechanical Loading: Do not place any equipment on top of a rack-mounted unit.

 

Circuit Overloading: Be sure that the supply circuit to the rack assembly is not overloaded.

 

Grounding: Rack-mounted equipment should be properly grounded. Particular attention 
should be given to supply connections other than direct connections to the mains.

To rack-mount devices:
1. Attach the two brackets to the device using the eight M4 screws provided in the rack 

mounting kit.

NOTE:
The switch can also be mounted in a rack using a rack shelf or rack “L” brackets.

(Figure 3-1: Attaching the Brackets)

2. Mount the device in the rack, using four 12-24 rack-mounting screws.

NOTE:
Rack screws and clip nuts are not supplied in the rack-mounting kit.

CAUTION:
Due to the switch’s weight, it should be installed by at least two people.

Содержание AG9032

Страница 1: ...Delta Networking Agema Family AG9032 v1 Spine and Leaf Switch Installation Guide ...

Страница 2: ...FR 47 Part 15 Subpart B Class A Safety Applicable standard EN 60950 1 Second Edition UL CSA 60950 1 Second Edition IEC 60950 1 Second Edition Including All National Immunity Applicable standard EN 300 386 EMC for Network Equipment EN 55024 EN 61000 3 2 Harmonic Current Emissions EN 61000 3 3 Voltage Fluctuations and Flicker EN 61000 4 2 ESD EN 61000 4 3 Radiated Immunity EN 61000 4 4 EFT EN 61000 ...

Страница 3: ...5 Power Supply Modules 7 2 6 Fan Tray Module 8 Chapter 3 Installation 9 3 1 Mounting 9 3 2 Installing an Optional QSFP QSFP28 Transceiver 11 3 3 Connecting to the Console Port 12 3 4 Connecting to a Power Source 12 Chapter 4 Making the Network Connections 15 4 1 Twisted pair Connections 15 4 2 Fiber Optic Connections 16 4 3 Ethernet Cabling 16 Appendix 1 Technical Specifications 17 Appendix 2 Warr...

Страница 4: ... for Data Center Networks also supports advance features such as MPLS TRILL PFC VEPA QCN VxLAN and NVGRE to meet the high demanding Data Center high performance and virtualization requirement This product is good for Data Center Aggregation switch application 1 2 Package Content After unpacking this switch check the contents to be sure you have received all the components Then before beginning the...

Страница 5: ...an Power status LED indication On board high performance CPU system with large memory Internal power supply Max power 800W AC version or 800W DC version Standard 1U chassis high 3 2 Tbps switching bandwidth Automatic address learning function to build the packet forwarding information table The table contains up to 136K MAC addresses Low pin to pin latency Cut Through Store and Forward Mode 16MB o...

Страница 6: ...1 USB port x 1 QSFP28 port x 32 RJ 45 Console port x 1 Figure 2 1 Front View 2 1 2 Rear View Redundant PSU x 2 5 Fan tray slots Figure 2 2 Rear View NOTE The switch supports up to two PSUs However it is shipped with one power supply pre installed in the rear panel of the switch You can purchase an additional PSU if necessary ...

Страница 7: ...rating normally Blinking Amber Power Supply 1 is failed Off Power is disconnected Power 2 LED Solid Green Power Supply 2 is supplied to the switch operating normally Blinking Amber Power Supply 2 is failed Off Power is disconnected Fan LED Solid Green FAN operating normally Solid Amber A FAN is failed 100G QSFP28 slots Four LEDs per port LED1 Off No link Solid Green A valid 100Gbps link 4x25G Soli...

Страница 8: ...n the port Solid Green A valid link at 1000Mbps is established on the port Act LED on the right side Off No link is established on the port Blinking Green Activity transmitting or receiving packet at this port 2 2 2 Rear LEDs PSU LED Fan LED Figure 2 4 Rear LED Identification LED Description Fan LED Green FAN operating normally Red FAN failed PSU LED Off Power failure or no power Solid Green Power...

Страница 9: ...auto negotiation Priority Queues 20 priority queues per port MAC Address Aging Support 1 000 000 seconds programable Default 300 seconds Spanning Tree Support Support IEEE802 1d STP Support IEEE802 1s MSTP Support IEEE802 1w RSTP Host Support 136K shared entries with MAC Table LPM Routes Support 128K shared entries with MAC Table Serial Console Provide visual feedback of the boot process to the us...

Страница 10: ...EM FAN MGMT AG7448 AG9032 v1 AG9032 v1 AG9032 v1 AG9032 v1 AG9032 v1 Figure 2 5 Converaged Ethernet Data Center Deployment 2 5 Power Supply Modules The power supply modules are hot swappable power supply units PSUs for the switch You can install up to two PSUs The PSUs operate in a load sharing mode and provides 1 1 redundancy Figure 2 6 Power Supply Unit NOTE 1 1 redundancy is a system where a sw...

Страница 11: ...Module The fan tray module is part of the switch air cooling system that provides cooling for the switch You must install the fan tray module in the switch that matches the airflow direction of the installed power supply unit Figure 2 7 Fan Tray Module ...

Страница 12: ... assembly is not overloaded Grounding Rack mounted equipment should be properly grounded Particular attention should be given to supply connections other than direct connections to the mains To rack mount devices 1 Attach the two brackets to the device using the eight M4 screws provided in the rack mounting kit NOTE The switch can also be mounted in a rack using a rack shelf or rack L brackets Fig...

Страница 13: ...mounting To mount devices on a horizontal surface follow these steps 1 Attach the four adhesive feet to the bottom of the first switch Figure 3 3 Attaching the Adhesive Feet 2 Set the device on a flat horizontal surface near an AC power source making sure there are at least two inches of space on all sides for proper air flow 3 If installing a single switch only go to Connecting to a Power Source ...

Страница 14: ...SFP28 transceiver type 2 Insert the transceiver with the optical connector facing outward and the slot connector facing down Note that QSFP QSFP28 transceivers are keyed so they can only be installed in one orientation 3 Slide the QSFP QSFP28 transceiver into the slot until it clicks into place NOTE QSFP QSFP28 transceivers are hot swappable The switch does not need to be powered off before instal...

Страница 15: ... to a Power Source 3 4 1 Installing an AC Power Supply To connect a switch to a power source 1 Insert the power cable plug directly into the AC socket of a PSU located at the back of the switch Power socket Figure 3 6 Power Socket 2 Plug the other end of the cable into a grounded 3 pin AC power source NOTE For International use you may need to change the AC line cord You must use a line cord set t...

Страница 16: ...s product is intended to be supplied by DC power source with rated 40 72Vdc 16A minimum Tma 40 degree C and the altitude of operation 3048 m The power cable should be 14AWG 16A minimum 72V minimum CAUTION Reversing polarity when connecting DC power wires can permanently damage the power supply or the system Always disconnect the power cable from power source before you service the power supply slo...

Страница 17: ...ude of operation 3048 m The power cable should be 14AWG 16A minimum 72V minimum CAUTION Reversing polarity when connecting DC power wires can permanently damage the power supply or the system Always disconnect the power cable from power source before you service the power supply slots 3 Check the PSU and front panel LEDs as the device is powered on to be sure that DC power is being received and th...

Страница 18: ...Category 3 or better for 10BASE T connections 4 1 1 Cabling Guidelines The RJ 45 port on the switch supports an automatic MDI MDI X pinout configuration so you can use a standard straight through twisted pair cable to connect to any other network device PCs servers switches routers or hubs 4 1 2 Connecting to the Management Port 1 Attach one end of a twisted pair cable segment to the link device s...

Страница 19: ...ort fiber connection Figure 4 2 Making QSFP28 Port Fiber Connection 4 3 Ethernet Cabling To ensure proper operation when installing the switch into a network make sure that the current cables are suitable for 10BASE T 100BASE TX or 1000BASE T operation Check the following criteria against the current installation of your network Cable type Unshielded twisted pair UTP or shielded twisted pair STP c...

Страница 20: ...b 1000BASE T on console port IEEE 802 3x Flow Control IEEE 802 3z 1000BASE X IEEE 802 3ae 10Gb s Ethernet Interface Information Interface Quad Small Form factor Pluggable QSFP28 slot x 32 10 100 1000Mbps Management port x 1 RJ45 Console port x 1 USB port x 1 Power Supply Unit Type AC in PSU DC in PSU Max output power 800W 800W Input voltage AC 100 240V DC 48 60V Output voltage DC 12V DC 12V Physic...

Страница 21: ...cturers to perform repairs and or to build replacement products All replaced or repaired products will be warranted for the remainder of the original warranty period or thirty 30 days whichever is longer Unless otherwise having a separate service level agreement SLA with Delta you may only have any in warranty product returned to Delta for repair or replacement in a normal turnaround time which di...

Страница 22: ...ranty defective product return you shall be responsible for proper packaging and Delta will not take responsibility for any shipping damage due to your improper product packaging Disclaimer EXCEPT FOR THE WARRANTIES EXPRESSLY SET FORTH IN THIS LIMITED AND SUPPORT WARRANTY DELTA MAKES NO OTHER WARRANTIES REGARDING THE PRODUCT ANY PARTS INCORPORATED THEREIN OR ANY SERVICES PROVIDED THEREWITH AND HER...

Страница 23: ......

Отзывы: