STEP 8:  Making Adjustments 

(Optional: Only required if factory settings are not preferred)

8.2  Dual Flush Adjustment Mode:

‡:KHQGXDOIOXVKLVDFWLYDWHGLWSURYLGHVDQDYHUDJHZDWHUUHGXFHGIOXVKZKHQ

users do not sit, or are sitting for less than 90

          seconds.  Pressing the electronic override button while dual flush mode is ON will produce a full flush.

‡

To turn Dual Flush Mode ON

 - while in dual flush adjustment mode, press the electronic override button so that the middle red light 

          is on.
       

‡  To turn Dual Flush MODE OFF

 - while in dual flush configuration, press the electronic override button and turn off the middle light, 

          leaving the other 2 lights on.
       

‡

  The Advanced Sensor Activated flush system will select flush zones based on the previously selected bowl length.

‡

 To advance to 24 Hour Flush Adjustment Mode, press and hold down the electronic override button for 5 seconds until solid blue light

          is present.
       

‡

  Release electronic override button.

8.3  24 Hour Flush Adjustment Mode:

‡:KHQWKHUHGOLJKWVDUHSUHVHQWKRXUIOXVKLV2)

F.

‡:KHQWKHUHGOLJKWVDUHSUHVHQWKRXUIOXVKLV21
‡3UHVVHOHFWURQLFRYHUULGHEXWWRQWRWRJJOHEHWZHHQ21DQG2))PRGH
‡

 To return to Operation Mode, press and hold down the electronic override button for 5 seconds until solid blue light is present.

       

‡

  Release electronic override button.

Exiting Set-Up Mode:

‡

  Can be accomplished in one of two ways;

   1.  During the 24 Hour Adjustment feature, press and hold down the electronic override button for 5 seconds until solid blue light is 
        present.  Release electronic override button.
   2.  During all modes, valve will revert back to operation mode automatically if the electronic override button is not pressed within 2
        minutes.

* After the last adjustment has been completed and the flush valve has returned to operation mode, there is a window of
  approximately 30 minutes where additional changes can be made.  If desired adjustments are not made within 30 minutes,
  the batteries must be disconnected for 10 seconds and then re-connected to obtain another adjustment period.  To make
  changes, begin at step #7 above.

INSTALLATION INSTRUCTIONS - RETROFIT BATTERY FLUSHOMETER (cont’d)

w w w . s p e c s e l e c t . c o m

8.1  SENSOR RANGE ADJUSTMENT MODE

- Press and release electronic override button to toggle
  through the settings
- Blue light flashes when object is detected
- Red lights signify bowl length choices

Lights visible
1 Red
2 Reds
3 Reds
4 Reds
5 Reds

8.3  24 HOUR FLUSH ADJUSTMENT

- Press and release electronic override button to toggle
  through the settings
- No Blue light will be present
- Red lights signify 24 Hour flush on or off

Lights visible
2 Reds 

 

 24 Hour Flush OFF

3 Reds 

 

 24 Hour Flush ON

ź

Fig. 5

ENTER SETUP MODE

TO ENTER SETUP MODE - HOLD DOWN
ELECTRONIC OVERRIDE BUTTON UNTIL
BLUE LIGHT IS PRESENT.  RELEASE
BUTTON.

EXIT SETUP MODE

TO EXIT SETUP AND RETURN TO
OPERATION MODE - HOLD DOWN
ELECTRONIC OVERRIDE BUTTON 
UNTIL BLUE LIGHT IS PRESENT.
RELEASE BUTTON.

HOLD DOWN ELECTRONIC
OVERRIDE BUTTON UNTIL
SOLID BLUE LIGHT PRESENT
TO ADVANCE RELEASE
BUTTON.

HOLD DOWN ELECTRONIC
OVERRIDE BUTTON UNTIL
SOLID BLUE LIGHT IS
PRESENT TO ADVANCE
RELEASE BUTTON.

W/C Bowl

Length

20”
22”
24”
26”
28”

Œ

Œ

Œ

Ź

Ź

ź

ź

ALL LIGHTS WILL BE ON, HOLD DOWN
THE ELECTRONIC OVERRIDE BUTTON

$*$,1817,/21/<7+(62/,'%/8(

LIGHT IS ON, RELEASE TO RETURN 
TO OPERATE MODE.

8.2  DUAL FLUSH ADJUSTMENT MODE 

- Press and release override to toggle through
  the settings
- Blue light and bottom red light stay on

Middle Red ON     -    Dual Flush ON
Middle Red OFF   -    Dual Flush OFF 

Содержание 81T BTRKA DF Series

Страница 1: ...ire versions order battery operated model with hardwire kit and transformer 210381 210381 210381 210381 210381 210381 210381 210381 Package Quantities May Change Check the parts section of the latest...

Страница 2: ...te clear case to access 4 screws on cast cap TIGHTEN the cast cap assembly to the flushometer valve body with the 4 screws item 9b Part 060078A see Fig 2 REPLACE metal cover insert cover screws and ti...

Страница 3: ...rical codes for a 1 amp load No 18 cable is usually sufficient from 24 VAC step down transformer into the electrical box VVHPEOH SODVWLF EXVKLQJ LQWR WKH KROH RQ WKH FRYHUSODWH 0HDVXUH DQG FXW WXEH DV...

Страница 4: ...f the electronic override button is not pressed within 2 minutes After the last adjustment has been completed and the flush valve has returned to operation mode there is a window of approximately 30 m...