STEP 8: Making Adjustments
(Optional: Only required if factory settings are not preferred)
8.2 Dual Flush Adjustment Mode:
:KHQGXDOIOXVKLVDFWLYDWHGLWSURYLGHVDQDYHUDJHZDWHUUHGXFHGIOXVKZKHQ
users do not sit, or are sitting for less than 90
seconds. Pressing the electronic override button while dual flush mode is ON will produce a full flush.
To turn Dual Flush Mode ON
- while in dual flush adjustment mode, press the electronic override button so that the middle red light
is on.
To turn Dual Flush MODE OFF
- while in dual flush configuration, press the electronic override button and turn off the middle light,
leaving the other 2 lights on.
The Advanced Sensor Activated flush system will select flush zones based on the previously selected bowl length.
To advance to 24 Hour Flush Adjustment Mode, press and hold down the electronic override button for 5 seconds until solid blue light
is present.
Release electronic override button.
8.3 24 Hour Flush Adjustment Mode:
:KHQWKHUHGOLJKWVDUHSUHVHQWKRXUIOXVKLV2)
F.
:KHQWKHUHGOLJKWVDUHSUHVHQWKRXUIOXVKLV21
3UHVVHOHFWURQLFRYHUULGHEXWWRQWRWRJJOHEHWZHHQ21DQG2))PRGH
To return to Operation Mode, press and hold down the electronic override button for 5 seconds until solid blue light is present.
Release electronic override button.
Exiting Set-Up Mode:
Can be accomplished in one of two ways;
1. During the 24 Hour Adjustment feature, press and hold down the electronic override button for 5 seconds until solid blue light is
present. Release electronic override button.
2. During all modes, valve will revert back to operation mode automatically if the electronic override button is not pressed within 2
minutes.
* After the last adjustment has been completed and the flush valve has returned to operation mode, there is a window of
approximately 30 minutes where additional changes can be made. If desired adjustments are not made within 30 minutes,
the batteries must be disconnected for 10 seconds and then re-connected to obtain another adjustment period. To make
changes, begin at step #7 above.
INSTALLATION INSTRUCTIONS - RETROFIT BATTERY FLUSHOMETER (cont’d)
w w w . s p e c s e l e c t . c o m
8.1 SENSOR RANGE ADJUSTMENT MODE
- Press and release electronic override button to toggle
through the settings
- Blue light flashes when object is detected
- Red lights signify bowl length choices
Lights visible
1 Red
2 Reds
3 Reds
4 Reds
5 Reds
8.3 24 HOUR FLUSH ADJUSTMENT
- Press and release electronic override button to toggle
through the settings
- No Blue light will be present
- Red lights signify 24 Hour flush on or off
Lights visible
2 Reds
24 Hour Flush OFF
3 Reds
24 Hour Flush ON
ź
Fig. 5
ENTER SETUP MODE
TO ENTER SETUP MODE - HOLD DOWN
ELECTRONIC OVERRIDE BUTTON UNTIL
BLUE LIGHT IS PRESENT. RELEASE
BUTTON.
EXIT SETUP MODE
TO EXIT SETUP AND RETURN TO
OPERATION MODE - HOLD DOWN
ELECTRONIC OVERRIDE BUTTON
UNTIL BLUE LIGHT IS PRESENT.
RELEASE BUTTON.
HOLD DOWN ELECTRONIC
OVERRIDE BUTTON UNTIL
SOLID BLUE LIGHT PRESENT
TO ADVANCE RELEASE
BUTTON.
HOLD DOWN ELECTRONIC
OVERRIDE BUTTON UNTIL
SOLID BLUE LIGHT IS
PRESENT TO ADVANCE
RELEASE BUTTON.
W/C Bowl
Length
20”
22”
24”
26”
28”
Ź
Ź
ź
ź
ALL LIGHTS WILL BE ON, HOLD DOWN
THE ELECTRONIC OVERRIDE BUTTON
$*$,1817,/21/<7+(62/,'%/8(
LIGHT IS ON, RELEASE TO RETURN
TO OPERATE MODE.
8.2 DUAL FLUSH ADJUSTMENT MODE
- Press and release override to toggle through
the settings
- Blue light and bottom red light stay on
Middle Red ON - Dual Flush ON
Middle Red OFF - Dual Flush OFF