background image

4

SAFETY R U L E S F O R

AIR C L E A N E R S

1.

F O R Y O U R O W N SAFETY,  READ INSTRUCTION

M A N U A L BEFORE OPERATING T H E TO OL. Learn the

tool s application and limitations as well as the specific

hazards peculiar to it.

2.

D O N O T A T T E M P T TO R E M O V E O R R E P L A C E

T H E FILTER(S) WHILE T H E M A C H I N E IS IN O P E R A-

TION. M A K E C E R TAIN AIR C L E A N E R IS D I S C O N-

N E C T E D F R O M T H E   P O W E R S O U R C E.

3.

D O N O T O P E R ATE T H E AIR C L E A N E R WITHOUT

T H E FILTER IN P L A C E TO AVOID E X P O S U R E TO  RO-

TATING PA R T S A N D OVERLOADING T H E M O TO R.

4.

T H E U S E of filters and attachments not recommend-

ed by Delta may result in product damage or the risk of

personal injury.

5.

When suspending the  Air Cleaner from the ceiling,

M A K E C E R TAIN the hardware is securely anchored into

a wood structure. Always keep a minimum of 7 feet

between bottom of Air Cleaner and the floor surface to

allow for adequate head clearance. Also, use only prop-

erly sized chain to prevent the tool from falling.

6.

TO R E D U C E T H E RISK O F ELECTRICAL SHOCK,

do not expose to water or rain, and do not lift the  Air

Cleaner by the power cord. D O N O T use the power cord

as a hanging device.

7.

When used in the portable application, M A K E C E R-

TAIN the Air Cleaner is adequately supported, or securely

clamped to the work surface to eliminate any potential for

movement or damage from falling.

8.

A LW AY S W E A R A D E Q U ATE E Y E PROTECTION.

9.

W H E N N O T IN USE, BE C E R TAIN TO STO R E AIR

C L E A N E R IN A S A F E L O C ATION TO ELIMINATE THE

POTENTIAL O F D A M A G E TO T H E P O W E R C O R D O R

TRIPPING H A Z A R D S.

10. M A K E W O R K S H O P C H I L D P R O O F by unplugging

tools from power source, using padlocks, or by using a

master switch.

11. MAINTAIN TO O L S IN TO P CONDITION. Keep filters

clean for optimum performance. Follow instructions for

changing and cleaning filters.

12. DANGER: D O N O T use this machine to filter any

metal dust. Combining wood and metal dust can create

an explosive hazard. This Air Cleaner is intended to be

used to filter non-explosive atmospheres only.

13. IF Y O U A R E N O T thoroughly familiar with the oper-

ation of the Air Cleaner, obtain advice from your super-

visor, instructor or other qualified person.

14. W ARNING: D O N O T operate your Air Cleaner until it

is completely assembled and installed according to the

instruction manual.

15. P L A C E P O W E R C O R D IN A S A F E L O C ATION TO

ELIMINATE TRIPPING HAZARDS.

16. U S E FA C E O R DUST MASK AND EYE PROTECTION.

W ARNING: The dust generated by certain woods and

wood products can be injurious to your health. Always

operate machinery in well-ventilated areas and provide

for proper dust removal.

17. W ARNING: TO AVOID A POTENTIALLY DANGER-

O U S SITUATION, DO N O T U S E AIR C L E A N E R TO DIS-

SIPATE F U M E S O R SMOKE. This Air Cleaner is intended

for use in non-explosive, non-metallic atmospheres where

only dry airborne dust is present.

18. G R O U N D  the Air Cleaner per National Electric Code

(N.E.C.) requirements

.

19. S AV E T H E S E INSTRUCTIONS. Refer to them fre-

quently and use them to instruct other users.

Содержание 50-860

Страница 1: ...national Machinery Corp 1998 Air Cleaner Model 50 860 Record this information for future reference SERIAL NO __________________________________ D ATE O F PURCHASE__________________________ See Table o...

Страница 2: ...n with proof of purchase of the product within two years and provides Delta with reasonable opportunity to ver ify the alleged defect by inspection Delta may require that electric motors be returned p...

Страница 3: ...1 2 W E A R PROPER APPAREL No loose clothing gloves neckties rings bracelets or other jewelry to get caught in moving pa r ts Nonslip footwear is recommended Wear protective hair covering to contain l...

Страница 4: ...O STO R E AIR CLEANER IN A SAFE LOCATION TO ELIMINATE THE POTENTIAL O F D A M A G E TO THE P O W E R C O R D O R TRIPPING HAZARDS 1 0 M A K E W O R K S H O P CHILDPROOF by unplugging tools from power...

Страница 5: ...rticles of the mentioned sizes will off e r a cleaner and safer environment T h i s Air Cleaner will filter the air in a room measuring 20 x 2 0 x8 sixteen times an hour I f d e s i r e d m u l t i p...

Страница 6: ...E 1 Locate 4 self adhesive rubber feet A Fig 3 sup plied with the unit Carefully place Air Cleaner on a firm supporting surface so there is access to the bottom of the cabinet as shown in F i g 3 App...

Страница 7: ...as necessary Make certain the flange nuts E Fig 6 are tightened down against the surface of the air cleaner a fter height adjustments are made When suspending the air cleaner from the ceiling or othe...

Страница 8: ...a n Improper connection of the equipment grounding con ductor can result in risk of electric shock The conductor with insulation having an outer surface that is green with or without yellow stripes is...

Страница 9: ...50 51 100 101 150 GAGE OF EXTENSION CORD TO USE 1 8 AW G 1 6 AW G 1 4 AW G 1 2 AW G ON OFF SWITCH The Air Cleaner is equipped with an in line rocker switch M Fig 11 located on the power cord N Tos ta...

Страница 10: ...an be used in dry wall and basement cleaning applications CAUTION W e recommend that the air cleaner be clamped as shown if using sawhorses as a supporting surface Fig 14 Fig 15 3 Fig 13 illustrates t...

Страница 11: ...CLEARANCE PROTECTION When suspending the air cleaner from the ceiling or other overhead support make certain the supporting hardware not supplied is securely anchored into a wooden supporting structu...

Страница 12: ...W AYS W E A R SAFETY GLASSES A N D DUST M A S K W H E N PERFORMING THIS PROCEDURE 4 The inner bag filter J Fig 19 cannot be cleaned it is disposable and must be replaced 5 I n s tall both filters in t...

Отзывы: