GROUNDED OUTLET BOX

CURRENT

CARRYING

PRONGS

GROUNDING BLADE
IS LONGEST OF THE 3 BLADES

GROUNDED OUTLET BOX

GROUNDING MEANS

ADAPTER

Fig. 21

120 VOLT,
SINGLE PHASE OPERATION

This tool must be grounded while in use to protect the
operator from electric shock. The motor recommended
for use with your dust collector is shipped wired for 120
Volt, Single Phase, and is equipped with an approved
3-conductor cord and 3-prong grounding type plug to
fit the proper grounding type receptacle, as shown in
Fig. 19. The green conductor in the cord is the
grounding wire. Never connect the green wire to a live
terminal.

A temporary adapter, shown in Fig. 20, is available for
connecting 3-prong grounding type plugs to 2-prong
receptacles if a properly grounded outlet is not available.
The temporary adapter should be used only until a
properly grounded outlet can be installed by a qualified
electrician.

THIS ADAPTER IS NOT APPLICABLE IN

CANADA.

The green-colored rigid ear, lug, etc.,

extending from the adapter, is the grounding means and
must be connected to a permanent ground such as to a
properly grounded outlet box, as shown in Fig. 20.
Whenever the adapter is used, it must be held in place
with a metal screw.

240 VOLT,
SINGLE PHASE OPERATION

The motor supplied with your tool is a dual voltage
120/240 volt motor. The dust collector motor is shipped
ready-to-run for 120 volt operation; however, it may be
converted for 240 volt operation.

The conversion of your dust collector for 240 volt
operation must be done by qualified electrical personnel.
Should you desire to have your dust collector converted
for 240 volts, take your dust collector to your local
Authorized Delta Service Center. Call 1-800-223-7278 for
the location of the nearest Authorized Service Center. The
Service Center will be able to convert your dust collector
for 240 volts by (a) re-wiring the motor for 240 volts; (b)
installing a 240 volt attachment plug to the power supply
cord; and (c) replacing the single pole on/off switch
shipped with your dust collector with a double pole switch.

The dust collector with a 240 volt plug should only be
connected to an outlet having the same configuration as
the plug illustrated in Fig. 21. No adapter is available or
should be used with the 240 volt plug.

CURRENT CARRYING PRONGS

GROUND PRONG

240 VOLT

AS A PRECAUTION IN ALL CASES, MAKE CERTAIN THE
RECEPTACLE IN QUESTION IS PROPERLY GROUNDED.
IF YOU ARE NOT SURE, HAVE A QUALIFIED ELECTRICIAN
CHECK THE RECEPTACLE.

GROUNDED OUTLET BOX

Содержание 50-775

Страница 1: ...l 50 775 PART NO 902116 015 Copyright 2001 Delta Machinery To learn more about DELTA MACHINERY visit our website at www deltamachinery com For Parts Service Warranty or other Assistance please call 1...

Страница 2: ...y to get caught in moving parts Nonslip footwear is recommended Wear protective hair covering to contain long hair 12 SECURE WORK Use clamps or a vise to hold work when practical It s safer than using...

Страница 3: ...with sharp edges hot surfaces oil or grease Do not place anything over the top of the power cord 9 DO NOT unplug the dust collector by pulling on the power cord DO NOT place anything over the top of t...

Страница 4: ...gasoline or lacquer thinner for this purpose After cleaning cover the unpainted surfaces with a good quality household floor paste wax 1 Motor and blower assembly 2 Base 3 Wheel casters 4 4 Side suppo...

Страница 5: ...en securely Fig 3 Fig 4 ASSEMBLING SIDE SUPPORTS 1 Place the dust collector base A Fig 5 in an upright position as shown 2 Align the two holes in the bottom of side support B Fig 5 with the two holes...

Страница 6: ...ached to the side supports Fig 8 Fig 9 ASSEMBLING FIRM BOARD 1 Place the firm board A inside the two side supports B Fig 10 NOTE MAKE SURE FIRM BOARD IS ATTACHED TO THE SIDE SUPPORTS CLOSEST TO THE MO...

Страница 7: ...essary to adjust the height of the drum support rod at this time If adjustment is necessary loosen nut A Fig 13 and rotate support rod B as needed to obtain proper rod height to support filter bag F T...

Страница 8: ...which accept the tool s plug Before connecting the motor to the power line make sure the switch is in the OFF position and be sure that the electric current is of the same characteristics as indicated...

Страница 9: ...ver the adapter is used it must be held in place with a metal screw 240 VOLT SINGLE PHASE OPERATION The motor supplied with your tool is a dual voltage 120 240 volt motor The dust collector motor is s...

Страница 10: ...240 50 100 16 AWG 0 6 240 100 200 16 AWG 0 6 240 200 300 14 AWG 6 10 240 up to 50 18 AWG 6 10 240 50 100 16 AWG 6 10 240 100 200 14 AWG 6 10 240 200 300 12 AWG 10 12 240 up to 50 16 AWG 10 12 240 50 1...

Страница 11: ...inate potential cord damage MOTOR MAINTENANCE Removing dust and dirt Blow off motor with low pressure air to remove dust or dirt Air pressure above 50 P S I should not be used as high pressure may dam...

Страница 12: ...12 NOTES...

Отзывы: