background image

5

SAVE THESE INSTRUCTIONS.

Refer to them often

and use them to instruct others.

DO NOT USE THIS UNIT TO FILTER 
METAL DUST.
 Combining wood and 
metal dust can create an explosion or 
fire hazard. This unit is intended to filter 
non-explosive atmospheres only.

DO NOT USE THIS UNIT TO DISSIPATE 
FUMES OR SMOKE.
 Explosions or fire 
can result. This dust collector is intended 
for use where only dry airborne dust is 
present. Its use should be limited to non-
explosive, non-metallic atmospheres.

1. 

DO NOT OPERATE THIS UNIT UNTIL IT IS 
COMPLETE-LY ASSEMBLED AND INSTALLED 
ACCORDING TO THE INSTRUCTIONS
. A unit 
incorrectly assembled can cause injury.

2. 

OBTAIN ADVICE FROM YOUR SUPERVISOR, 
IN-STRUCTOR, OR ANOTHER QUALIFIED 
PERSON 
if you are not thoroughly familiar with the 
operation of this unit. Knowledge is safety

3. 

FOLLOW ALL WIRING CODES and recommended 
electrical connections to prevent electrical shock 
or electrocution.

4. 

DO NOT PULL THIS UNIT BY THE POWER 
CORD
. Do not allow the power cord to come 
in contact with sharp instruments or edges, hot 
surfaces, or oil or grease. Do not place any weight 
on top of the power cord. A damaged power cord 
can cause electrical shock or electrocution.

5. 

ENSURE THAT THE INTAKE AND EXHAUST 
AREAS ARE CLEAR PRIOR TO STARTING THE 
UNIT.
 Clogged intakes or exhausts can cause an 
explosion and/or fire.

6. 

DO NOT USE THE DUST COLLECTOR to pick 
up flammable liquids such as gasoline. Do not use 
the dust collector near flammable or combustible 
liquids. Explosion and/or fire can occur.

7.  KEEP ARMS, HANDS, AND FINGERS AWAY 

FROM THE FAN. Avoid all exposure to rotating 
parts to prevent  injury.

8. 

DO NOT OPERATE THIS UNIT WITHOUT THE DUST 
COLLECTION BAG IN PLACE AND PROPERLY 
SECURED
. Sawdust and other debris can provide the 
potential for fire and/or explosion and can also cause 
inhalation problems.

9. 

INSPECT THE DUST BAG FOR CUTS, RIPS, OR 
TEARS.
 Replace damaged bags or vacuum hoses. 
Sawdust and other debris can provide the potential 
for fire and/or explosion and can also cause inhalation 
problems.

10.  ALWAYS USE THE INTAKE CAPS TO COVER 

UNUSED DUST PORTS. Debris can cause damage 
to the unit and  injury. 

11.  DO NOT ATTEMPT TO REMOVE OR REPLACE 

the dust collection bag(s) while the unit is connected 
to the power source. Exposed fan blades can cause 
severe injuries. 

12.  MAINTAIN THE UNIT IN TOP CONDITION. 

Clogged filters can increase the potential for fire or 
explosion. Follow all instructions for changing and 
cleaning filters.

13.  STORE THIS UNIT IN A LOCATION that eliminates 

the potential for damage to the power cord. 
A damaged power cord can cause shock or 
electrocution. Safely store power cord on the unit 
to eliminate tripping hazards.

14.  TURN THE UNIT “OFF” AND DISCONNECT THE 

UNIT  from the power source before installing or 
removing accessories, before adjusting or changing 
set-ups, or when making repairs. An accidental 
start-up can cause serious injury.

15.  TURN THE UNIT “OFF”, disconnect the unit from 

the power source, and clean the table/work area 
before leaving the area. 

Failure to follow these rules may result in serious personal injury.

ADDITIONAL SPECIFIC SAFETY RULES

Содержание 50-762

Страница 1: ...800 463 3582 CANADA Instruction Manual Manuel d Utilisation Manual de Instrucciones 50 762 50 763 FRAN AIS 15 ESPA OL 29 A16999 04 28 06 Copyright 2006 Delta Machinery Recolector de polvo de 3 H P 3...

Страница 2: ...deltamachinery com Postal Mail Technical Service Manager Delta Machinery 4825 Highway 45 North Jackson TN 38305 IN CANADA 125 Mural St Suite 300 Richmond Hill ON L4B 1M4 Information regarding the saf...

Страница 3: ...y damage It is important for you to read and understand this manual The information it contains relates to protecting YOUR SAFETY and PREVENTING PROBLEMS The symbols below are used to help you recogni...

Страница 4: ...damage to the machine or injury to the user 14 USE THE PROPER EXTENSION CORD Make sure your extension cord is in good condition When using an extension cord be sure to use one heavy enough to carry th...

Страница 5: ...e or combustible liquids Explosion and or fire can occur 7 KEEP ARMS HANDS AND FINGERS AWAY FROM THE FAN Avoid all exposure to rotating parts to prevent injury 8 DO NOT OPERATE THIS UNIT WITHOUT THE D...

Страница 6: ...m and grounded according to the National Electrical Code You CANNOT use extension cords with these three phase machines For instructions on how to wire three phase or single phase motors check the sec...

Страница 7: ...10 14 15 16 Bracket for Bag hanging Rod 2 17 5 16 x 3 4 Hex Head Screws 22 6 are for attaching the bracket 18 5 16 8mm Flat Washer for Bracket 6 16 17 18 UNPACKING AND CLEANING Carefully unpack the m...

Страница 8: ...ighten the hardware by hand and then set it with a 12mm wrench NOTE This step requires two people Place all four stand posts A Fig 3 into the four legs B on the motor blower assembly Make sure that th...

Страница 9: ...ake ports on bottom Fig 4 You can also assemble this unit with the intake port B Fig 5 in the up position by following the steps in ATTACHING THE LEGS TO THE MOTOR BLOWER ASSEMBLY The difference in as...

Страница 10: ...lamp B Fig 10 1 Place the clamp B around the top of the plastic bag A Fold about 4 to 6 inches of plastic bag over the clamp Fig 10 2 Place the clamp and plastic bag A Fig 11 on the blower assembly Fa...

Страница 11: ...to the woodworking machine NOTE Do not operate the dust collector with any of the holes in dust intake port C Fig 14 uncovered To cover a hole not being used by a hose place the flat intake cap E on d...

Страница 12: ...lectrical system and grounded to meet code MODEL 50 763 SINGLE PHASE INSTALLATION 1 Remove the controller cover A Fig 17 2 Bring the singlephase power line through the access hole B Fig 17 in the bott...

Страница 13: ...at 1 800 223 7278 In Canada call 1 800 463 3582 MAINTENANCE KEEP MACHINE CLEAN Periodically blow out all air passages with dry compressed air All plastic parts should be cleaned with a soft damp clot...

Страница 14: ...with this product use of such accessories could be hazardous For safest operation only Delta recommended accessories should be used with this product ACCESSORIES Two Year Limited New Product Warranty...

Страница 15: ...15 FRAN AIS...

Страница 16: ...orte quelles questions relatives son application n utilisent pas le produit jusqu ce que vous avez crit Porter Cable et nous vous avons conseill La forme en ligne de contact www deltamachinery com Cou...

Страница 17: ...prolongateur est en bon tat Lorsqu un cordon prolongateur est utilis s assurer que celui ci est d un calibre suffisant pour l alimentation n cessaire la machine Un cordon d un calibre insuffisant entr...

Страница 18: ...fice d admission ou d vacuation ob stru risque de provoquer une explosion et ou un incendie 7 NE PAS UTILISER LE D POUSSI REUR pour ramasser des liquides inflammables comme l essence Ne pas utilis er...

Страница 19: ...ue de l difice et correctement mis la terre Dans ce cas il est impossible d utiliser des rallonges avec ces d poussi reurs Pour des directives propos du c blage de moteurs triphas s ou monophas s cons...

Страница 20: ...poussi re 4 2 Anneaux de retenue du sac gain s de tissu 5 2 Sacs filtrants sup rieurs de 1 microm tre 6 4 Sacs plastiques inf rieurs capacit filtrante de 152 4 microm tres 6 mils 7 2 Pattes 8 2 Bride...

Страница 21: ...neaux 12 4 Boutons pour le module moteur souffleur 13 4 Rondelles plates de 9 5 mm 3 8 po pour les boutons 14 16 Rondelles plates de 8 mm 5 16 po pour les roulettes 15 4 Vis t le M4 pour la goulotte p...

Страница 22: ...moteur souffleur avec le moteur A fig 2 en bas 2 Enfiler une rondelle plate de 18 mm 3 8 po sur le bouton B 3 Aligner les trous des pattes C avec ceux D du module moteur souffleur Les pattes devraien...

Страница 23: ...QUE avant de d buter l assemblage alternatif retirer les vis t te hexagonale de 8 MM 5 16 PO des trous B fig 6 du module moteur souffleur et les ins rer dans les trous C Il y aura une fuite d air si l...

Страница 24: ...e B fig 9 Le plier pour l ajuster en position B fig 3 Tirer l g rement sur le sac pour liminer tout mou et s assurer qu il soit solidement fix pour emp cher qu il ne se d tache en cours de d poussi ra...

Страница 25: ...ac filtrant de la m me fa on RACCORD DU TUYAU ACCESSOIRE L ORIFICE D ADMISSION D brancher l appareil de la source d alimentation Les mod les 50 762 et 50 763 comportent quatre orifices de 10 cm 4 po p...

Страница 26: ...on du moteur soit dans la bonne direction Le ventilateur devrait tourner en sens horaire Il est possible d inverser la rotation du moteur en interchangeant n importe quel deux fils des trois fils acti...

Страница 27: ...doigts et tout objet tranger de la goulotte poussi re suivre les consignes en mati re de s curit du pr sent manuel FONCTIONNEMENT A B Fig 19 C Fig 20 D MARRAGE ET ARR T DU D POUSSI REUR Les boutons d...

Страница 28: ...gager r guli rement toutes les conduites d air avec de l air comprim sec Toutes les pi ces en plastique doivent tre net toy es l aide d un chiffon doux humide NE JAMAIS utiliser de solvants pour netto...

Страница 29: ...29 ESPA OL...

Страница 30: ...RDE ESTAS INSTRUCCIONES Indica una situaci n de inminente riesgo la cual si no es evitada causar la muerte o lesiones serias Indica una situaci n potencialmente riesgosa que si no es evitada podr a re...

Страница 31: ...s condiciones Cuando utilice un cord n de extensi n aseg rese de utilizar un cord n que sea lo suficientemente pesado como para llevar la corriente que su producto tome Un cord n de tama o insuficient...

Страница 32: ...pa holgada los dedos y todas las partes del cuerpo alejados de las aberturas y las piezas m viles del colector de polvo 9 NUNCA utilice el colector de polvo sin la bolsa de recolecci n de polvo coloca...

Страница 33: ...n el C digo El ctrico Nacional Dado que deben estar conectados permanentemente al sistema el ctrico del edificio no se puede usar cables prolongadores con estos recolectores Para obtener instrucciones...

Страница 34: ...Rueda 4 11 Tapa y anillo de entrada 4 12 Perilla para el conjunto del soplador y motor 4 13 Arandela plana de 9 5 mm 3 8 para las perillas 4 14 Arandelas planas de 8 mm 5 16 para las ruedas 16 15 Tor...

Страница 35: ...as las perillas de ambas patas C MO CONECTAR LAS PATAS A LA BASE DEL CONJUNTO DEL MOTOR Y SOPLADOR NOTA Para este paso se requieren dos personas Coloque los cuatro postes de la base A Fig 3 en las cua...

Страница 36: ...illos de cabeza hexagonal de 8 MM 5 16 de los orificios B Fig 6 en el conjunto de motor y soplador y col quelos en los orificios C Si los tornillos no se encuentran colocados en los orificios habr una...

Страница 37: ...egue el anillo para que calce en su lugar 3 Tire un poco de la bolsa para que no quede floja y asegurarse de que est segura y no se desconectar durante la recolecci n de polvo 4 Repetici n para el otr...

Страница 38: ...ien en su lugar 8 Conecte la otra bolsa de filtro de la misma forma C MO CONECTAR LA MANGUERA ACCESORIA AL ORIFICIO DE ADMISI N Desconecte la m quina de la fuente de energ a Los modelos 50 762 50 763...

Страница 39: ...tilador del soplador para asegurarse de que el motor gire en la direcci n correcta El ventilador debe rotar en sentido de las agujas del reloj Usted puede invertir la rotaci n del motor intercambiando...

Страница 40: ...A SIN CUBRIR TODOS LOS ORIFICIOS DE ADMISI N DE POLVO SE PUEDE ACCEDER AL VENTILADOR GIRATORIO QUE SE ENCUENTRA DENTRO DE LA CAJA DEL SOPLADOR A TRAV S DEL ORIFICIO DE ADMISI N DE POLVO LO CUAL PUEDE...